PubMed · 9586714
Tin shielding thicknesses for electrons.
Abstract
The transmission of 6, 9, 12, 16, and 20 MeV electrons from a linear accelerator through tin and lead is studied at 0.5 cm depth in polystyrene. These measurements are performed using a 10 x 10 cm2 cone and extend well into bremsstrahlung region. The results show certain advantages of using tin to shield sensitive organs from electron beams. Tin is non-toxic and creates less additional bremsstrahlung even though it must be thicker than the equivalent lead shield.
Explore related subjects
Keep this discovery
Explore connections, maps & timelines
S Guru Prasad, K Parthasaradhi, W H Al-Najjar, W D Bloomer. 1998. Tin shielding thicknesses for electrons.. https://doi.org/10.1016/s0958-3947(97)00111-8