PubMed Health⌕ Search

PubMed · 997705

[Data processing system for laboratory and hemodynamic heart catheterization measurements].

Abstract

In cooperation with the Department of Electronic Data Processing Systems we have developed a data processing unit for the analysis of hemodynamic data at the Department of Internal Medicine I. The aim was to design a computer-system for the daily routine in heart-catheterizations as well as for the solution of scientific problems during hemodynamic studies. In the on-line-mode besides the ECG up to four pressures can be analysed simultaneously. Analog and digital tapes can also be processed off-line on demand. The concept of the whole system and the individual steps of computer-handling are adjusted to the problems of data-analysis in praxis from the viewpoint of the examining cardiologist. Since the system is interactive after each measurement and each given command the computer-results are displayed on the video-scope. Because of the modular structure of the program new medical criteria can easily be implemented at any time. Since the computer-system is not effectively used with only one cath-lab other units possibly of different hard-ware configuration can be connected simultaneously to the computer. Each cath-lab shares 16 K out of the total 32 K core-memory. The results are displayed graphically and alpha-numerically on video-scope, x-y-plotter and line printer. The sampling-rate for fluid-filled catheters is 200 Hz and for catheter-tip-manometers 400 Hz. Smothing and differentiation-procedures are adapted to the respective catheter-material. The computer-program calibrates the different pressure amplifiers automatically. After defining the catheter-position the pressure-signals are sampled for 10 s and immediately afterwards analyzed by the computer. The ECG and the corresponding pressure-curves are displayed on the video-scope. The automatically selected representative beat as well as each of the identified and numerated other beats of the sampling-phase can be displayed selectively together with its numerical results. The computer marks the positions within the pressure-curves, where the individual measurements were taken. Besides the systolic and diastolic pressures in valvular stenosis the maximal and mean systolic or diastolic gradients, ejection- or filling-period, valve-flow and valve-area are calculated autonomously. The calculation of cardiac-output, different volume-indices and stroke-work-index are based on Fick-method, thermo- or indicator-dilution technique. The contractility-parameters max dp/dt, t-max dp/dt, max dp/dt/DP, max dp/dt/P, VPM, V40, min dp/dt and the stiffness are computed for the left and on demand also for the right ventricle. Data of the patient and the operating-team, catheter-technique, complications and free comments are transmitted to the computer via terminal together with the actual time. The computer-system was drafted for permanent use. Therefore possible technical defects have been anticipated in the design of hard- and soft-ware. In cases of failure suitable steps allow the immediate restart of the system without loosing information...

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P Jensch, J Meyer, E Mattar, W Ameling, S Effert. 1976. [Data processing system for laboratory and hemodynamic heart catheterization measurements].. https://pubmed.ncbi.nlm.nih.gov/997705/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An experimental study of apico-aortic valved conduit (AAVC) for surgical treatment of aortic stenosis in dogs.

A new valved conduit was developed using a canine aortic valve. The bioprosthetic valve was fixed with glutaraldehyde and epoxy compound (Denacol-EX313/810). A vascular graft composed of ultra-fine polyester fiber (10 mm in diameter, 200 mm in length) was used. Four dogs underwent apico-aortic valved conduit (AAVC) implantation and aortic banding (bypass group, BG), while another 4 dogs underwent aortic banding without AAVC implantation (control group, CG). Cardiac catheterization and angiocardiography were performed for assessment of hemodynamics 2 weeks and 6 months after surgery. Left ventricular systolic pressure, left ventricular end-diastolic pressure and the left ventricular-aortic pressure gradient differed significantly (P<0.01) between the BG and CG dogs. Left ventricular angiocardiography showed patency of the valved conduit in all the BG dogs. Echocardiography was performed before and 2, 4 and 6 months after surgery, and showed that while pressure overload caused concentric myocardial hypertrophy in the CG dogs, the left ventricle dilated eccentrically in the BG dogs. Furthermore, relief of left ventricular pressure overload by AAVC was maintained.

Angiocardiography↗

A new variant of aberrant left brachiocephalic trunk in mam: case report and literature review.

Importance is placed on aberrant arteries in the radiological and surgical literature. A normal left brachiocephalic trunk is characteristic for the right aortic arch. However, an aberrant left brachiocephalic trunk arising as the last branch of the aortic arch on the left side has not yet been described in the literature. Described here is a new variant of the retro-oesophageal aberrant left brachiocephalic trunk, occasionally observed in a patient during diagnostic investigation or surgical treatment for steno-obstructive involvement of the carotid district. The triple anomaly of the left aortic arch consisted of: 1. the presence of a hypoplastic left brachiocephalic trunk behind the oesophagus, 2. the absence of a brachiocephalic trunk on the right side and 3. separate origins of the arteries on the right side, with the right common artery preceding the right subclavian artery. In front of the trachea an 8-mm prosthetic PTFE was implanted from the proximal segment of the right subclavian artery to the junction of the left common carotid and left subclavian arteries. The author demonstrates the inadequacy of auxiliary investigations to detect aberrant arteries, which may only be identified precisely intra-operatively.

Angiocardiography↗

[Atypical takotsubo cardiomyopathy with preservation of apical contraction: a case report including pathological findings].

A 60-year-old woman presented with sudden chest and back pain. Electrocardiography suggested anterior myocardial infarction but coronary angiography revealed no significant stenosis in the coronary artery. Left ventriculography revealed akinesis of the mid ventricle and preserved contraction of the apical wall. The clinical condition of atypical left ventricular akinesia was suggested to be the same as conventionally reported typical takotsubo cardiomyopathy. Repeated left ventriculography revealed the abnormal wall motion had disappeared. The findings of endomyocardial biopsy were compatible with takotsubo cardiomyopathy. Although the clinical presentation of the left ventricle is atypical, the pathological findings may be the same as typical takatsubo cardiomyopathy.

Angiocardiography↗