PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “biosensor”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10Linked to original sources

Novel planar glucose biosensors for continuous monitoring use.

Novel planar glucose biosensors to be used for continuous monitoring have been developed. The electrodes are produced with the "screen printing" technique, and present a high degree of reproducibility together with a low cost and the possibility of mass production. Prior to enzyme immobilisation, electrodes are chemically modified with ferric hexacyanoferrate (Prussian Blue). This allows the detection of the hydrogen peroxide produced by the enzymatic reaction catalysed by GOD, at low applied potential (ca. 0.0 V versus Ag/AgCl), highly limiting any electrochemical interferences. The layer of Prussian Blue (PB) showed a high stability at the working conditions (pH 7.4) and also after 1 year of storage dry at RT, no loss of activity was observed. The assembled glucose biosensors, showed high sensitivity towards glucose together with a long-term operational and storage stability. In a continuous flow system, with all the analytical parameters optimised, the glucose biosensors detected glucose concentration as low as 0.025 mM with a linear range up to 1.0mM. These probes were also tested over 50-60 h in a continuous flow mode to evaluate their operational stability. A 0.5 mM concentration of glucose was continuously fluxed into a biosensor wall-jet cell and the current due to the hydrogen peroxide reduction was continuously monitored. After 50-60 h, the drift of the signal observed was around 30%. Because of their high stability, these sensors suggest the possibility of using such biosensors, in conjunction with a microdialysis probe, for a continuous monitoring of glucose for clinical purposes.

Biosensing Techniques↗

Amperometric microbial biosensor for p-nitrophenol using Moraxella sp.-modified carbon paste electrode.

An amperometric microbial biosensor for highly specific, sensitive and rapid quantitative determination of p-nitrophenol was developed. The biosensor takes advantage of the ability of Moraxella sp. to specifically degrade p-nitrophenol to hydroquinone, a more electroactive compound than p-nitrophenol. The electrochemical oxidation current of hydroquinone formed in biodegradation of p-nitrophenol was measured at Moraxella sp.-modified carbon paste electrode and correlated to p-phenol concentrations. The optimum response was realized by electrode constructed using 15 mg of dry cell weight per 1 g of carbon paste and operating at 0.3 V (versus Ag/AgCl reference) in pH 7.5, 20 mM sodium phosphate buffer. Operating at these optimum conditions the biosensor had excellent selectivity against phenol derivatives and was able to measure as low as 20 nM (2.78 ppb) p-nitrophenol with very good accuracy and reproducibility. The biosensor was stable for approximately 3 weeks when stored at 4 degrees C. The applicability of the biosensor to measure p-nitrophenol in lake water was demonstrated.

Biological Assay↗

The biosensor based on the pyruvate oxidase modified conducting polymer for phosphate ions determinations.

An enzymatic biosensor was fabricated by the covalent immobilization of pyruvate oxidase (PyO) onto the nano-particle comprised poly-5,2':5',2''-terthiophene-3'-carboxylic acid, poly-TTCA (nano-CP) layers on a glassy carbon electrode (GCE) for the amperometric detection of the phosphate ions. The direct electron transfer reaction of the immobilized PyO onto the nano-CP layers was investigated and the electron transfer rate constant was determined to be 0.65 s(-1). The electrochemically prepared nano-CP lowered the oxidation potential (+0.40 V versus Ag/AgCl) of an enzymatically generated H(2)O(2) by PyO in a phosphate solution. Experimental parameters affecting the sensitivity of the biosensors, such as amounts of the cofactors, the pH, the applied potential, and the temperature were optimized. A linear response for the detection of the phosphate ion was observed between 1.0 microM and 100 microM and the detection limit was determined to be about 0.3 microM. The response time of the biosensors was about 6s. The biosensor showed good selectivity towards other interfering anions. The long-term storage stability of the phosphate biosensor was studied and the sensor was applied in a human serum sample for the phosphate ions detection.

Biosensing Techniques↗

A novel FRET-based optical fiber biosensor for rapid detection of Salmonella typhimurium.

A biosensor that is portable and permits on-site analysis of samples would significantly reduce the large economical burden of food products recalls. A fiber optic portable biosensor utilizing the principle of fluorescence resonance energy transfer (FRET) was developed for fast detection of Salmonella typhimurium (S. typhimurium) in ground pork samples. Labeled antibody-protein G complexes were formed via the incubation of anti-Salmonella antibodies labeled with FRET donor fluorophores (Alexa Fluor 546) and protein G (PG) labeled with FRET acceptor fluorophores (Alexa Fluor 594). Utilizing silanization, the labeled antibodies-PG complexes were then immobilized on decladded, tapered silica fiber cores to form the evanescent wave-sensing region. The biosensors were tested in two different solutions: (1) PBS doped with S. typhimurium and (2) homogenized pork sample with S. typhimurium. The fiber probes tested in a S. typhimurium doped phosphate buffered solution demonstrated the feasibility of the biosensor for detecting S. typhimurium as well as determined the optimal packing density of the labeled antibody-PG complexes on the surface of fibers. The results showed that a packing density of 0.033 mg/ml produced the lowest limit of detection of 10(3)cells/ml with 8.2% change in fluorescence. The fiber probes placed in homogenized pork samples inoculated with S. typhimurium showed a limit of detection of 10(5)CFU/g with a 6.67% in fluorescence within a 5-min response time. These results showed that the FRET-based fiber optic biosensor can become a useful analytical tool for detection of S. typhimurium in real food samples.

Animals↗

A resazurin-based biosensor for organic pollutants.

A new rapid biosensor method employing the dye resazurin as an indicator of bacterial respiration has been developed to provide a rapid, facile and specific biosensor for environmental contaminants that does not rely on genetic modification techniques, is suitable for a high-throughput multiwell format, and is ideally suited to resource-constrained environmental monitoring situations. This whole-cell biosensor has been applied to the test analyte toluene using natural toluene-degrading bacteria as the biological component and is competitive with more complex recombinant approaches. The redox-driven biosensor is dependent on the catabolism of a specific compound, concomitantly reducing the redox indicator resazurin to provide the analytical signal in a whole-cell biosensor assay.

Biological Assay↗

A noninterference polypyrrole glucose biosensor.

In order to eliminate the interference of impurities, such as ascorbic acid, a noninterference polypyrrole glucose biosensor was constructed with a four-electrode cell consisting of a polypyrrole film electrode, a polypyrrole-glucose oxidase electrode, a counter electrode and a reference electrode. The pure catalytic current of glucose oxidase (GOD) can be obtained from the difference between response currents of two working electrodes with and without GOD. The effects of potential, pH and temperature on analytical performance of the glucose biosensor were discussed. The optimum pH and apparent activation energy of enzyme-catalyzed reaction are 5.5 and 25 kJ mol(-1), respectively. The response current of the biosensor increases linearly with the increasing glucose concentration from 0.005 to 20.0 mmol dm(-3). The results show the glucose biosensor with under 2% of relative deviation has good ability of anti-interference. The glucose biosensor was also characterized with FT-IR and UV-vis spectra.

Biosensing Techniques↗

Development of a high analytical performance-tyrosinase biosensor based on a composite graphite-Teflon electrode modified with gold nanoparticles.

The design of a new tyrosinase biosensor with improved stability and sensitivity is reported. The biosensor design is based on the construction of a graphite-Teflon composite electrode matrix in which the enzyme and colloidal gold nanoparticles are incorporated by simple physical inclusion. Experimental variables such as the colloidal gold loading into the composite matrix, the enzyme loading and the potential applied to the bioelectrode were optimized. The Tyr-Au(coll)-graphite-Teflon biosensor exhibited suitable amperometric responses at -0.10 V for the different phenolic compounds tested (catechol; phenol; 3,4-dimethylphenol; 4-chloro-3-methylphenol; 4-chlorophenol; 4-chloro-2-methylphenol; 3-methylphenol and 4-methylphenol). The limits of detection obtained were 3 nM for catechol, 3.3 microM for 4-chloro-2-methylphenol, and approximately 20 nM for the rest of phenolic compounds. The presence of colloidal gold into the composite matrix gives rise to enhanced kinetics of both the enzyme reaction and the electrochemical reduction of the corresponding o-quinones at the electrode surface, thus allowing the achievement of a high sensitivity. The biosensor exhibited an excellent renewability by simple polishing, with a lifetime of at least 39 days without apparent loss of the immobilized enzyme activity. The usefulness of the biosensor for the analysis of real samples was evaluated by performing the estimation of the content of phenolic compounds in water samples of different characteristics.

Biosensing Techniques↗

Amperometric glucose biosensor based on polymerized ionic liquid microparticles.

A glucose amperometric biosensor based on the immobilization of glucose oxidase (GOx) in microparticles prepared by polymerization of the ionic liquid 1-vinyl-3-ethyl-imidazolium bromide (ViEtIm+ Br-) using the concentrated emulsion polymerization method has been developed. The polymerization of the emulsion dispersed phase, in which the enzyme was dissolved together with the ionic liquid monomer, provides poly(ViEtIm+ Br-) microparticles with entrapped GOx. An anion-exchange reaction was carried out for synthesizing new microparticles of poly(ViEtIm+ (CF3SO2)2N-) and poly(ViEtIm+ BF4-). The enzyme immobilization method was optimized for biosensor applications and the following optimal values were determined: pH 4.0 for the synthesis medium, 1.23 M monomer concentration and 3.2% (w/w) cross-linking content. The performance of the biosensor as a function of some analytical parameters such as pH and temperature of the measuring medium, and enzymatic load of the microparticles was also investigated. The effect of the substances which are present in serum samples such as uric and ascorbic acid was eliminated by using a thin Nafion layer covering the electrode surface. The biosensor thus prepared can be employed in aqueous and in non-aqueous media with satisfactory results for glucose determination in human serum samples. The useful lifetime of this biosensor was 150 days.

Biosensing Techniques↗

A reagentless optical biosensor based on the intrinsic absorption properties of peroxidase.

During the reversible reaction between peroxidase (HRP) and H(2)O(2), several peroxidase intermediate species, showing different molecular absorption spectra, are formed which can be used for H(2)O(2) determination; when H(2)O(2) is generated in a previous enzymatic reaction, the substrate involved in this reaction can also be determined. On this basis, a new family of fully reversible reagentless optical biosensors containing HRP is presented; glucose determination is used as a model. The biosensor (which can be used for at least 6 months and/or more than 750 measurements) is prepared by HRP and glucose oxidase entrapment in a polyacrylamide gel matrix. A mathematical model (in which optical, kinetic and transport aspects are considered) relating the measured absorbance with the substrate concentration is also presented together with a simple methodology for characterization of this kind of biosensor. Regarding the optical model, the Kubelka-Mulk theory of reflectance does not give good results and the biosensors are better described by the Rayleigh theory of polymer solutions. Under working conditions, linear response ranges from 1.5x10(-6) to 3.0x10(-4)M glucose and CV was about 4%. This biosensor has been applied for glucose determination in fruit juices and synthetic serum samples without sample pretreatment.

Absorption↗

Amperometric third-generation hydrogen peroxide biosensor based on the immobilization of hemoglobin on multiwall carbon nanotubes and gold colloidal nanoparticles.

A convenient and effective strategy for preparation nanohybrid film of multi-wall carbon nanotubes (MWNT) and gold colloidal nanoparticles (GNPs) by using proteins as linker is proposed. In such a strategy, hemoglobin (Hb) was selected as model protein to fabricate third-generation H2O2 biosensor based on MWNT and GNPs. Acid-pretreated, negatively charged MWNT was first modified on the surface of glassy carbon (GC) electrode, then, positively charged Hb was adsorbed onto MWNT films by electrostatic interaction. The {Hb/GNPs}n multilayer films were finally assembled onto Hb/MWNT film through layer-by-layer assembly technique. The assembly of Hb and GNPs was characterized with cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS) and transmission electron microscopy (TEM). The direct electron transfer of Hb is observed on Hb/GNPs/Hb/MWNT/GC electrode, which exhibits excellent electrocatalytic activity for the reduction of H2O2 to construct a third-generation mediator-free H2O2 biosensor. As compared to those H2O2 biosensors only based on carbon nanotubes, the proposed biosensor modified with MWNT and GNPs displays a broader linear range and a lower detection limit for H2O2 determination. The linear range is from 2.1x10(-7) to 3.0x10(-3) M with a detection limit of 8.0x10(-8) M at 3sigma. The Michaelies-Menten constant KMapp value is estimated to be 0.26 mM. Moreover, this biosensor displays rapid response to H2O2 and possesses good stability and reproducibility.

Biosensing Techniques↗

Detection of SEB gene by bilayer lipid membranes nucleic acid biosensor supported by modified patch-clamp pipette electrode.

This work reports a kind of novel bilayer lipid membranes (BLMs) nucleic acid biosensor supported by modified patch-clamp pipette electrode was developed to detect staphylococcus enterotoxins B (SEB) gene. BLMs were formed within 15 min and able to be operated at least 24 h. Hydrophobic dodecane tail (C12) modified 18 bp single-stranded DNA (ssDNA) probe was immobilized on BLMs. The electrochemical currents versus the different concentration of ssDNA probe immobilized on BLMs indicated linearly correlation. The BLMs nucleic acid biosensor was fabricated by selecting the ssDNA probe as the signal sensing element with the concentration of 273.65 ng/mL. The electrochemical performance of the biosensor for the detection of SEB was investigated. The result showed that linear relationship was found between the current and ln(concentration) from 20 to 5000 ng/mL and the detection limit was 20 ng/mL. In addition, the biosensor was specific response to SEB gene and showed no significant current alteration in electrolyte which containing no SEB gene. Finally, Atom Force Microscope (AFM) images could be observed and used to evaluate the superficial microstructure of BLMs, ssDNA immobilized on BLMs and BLMs after hybridization. The BLMs nucleic acid biosensor supported by modified patch-clamp pipette electrode will become a highly sensitive, rapid, selective analytical tool for detection of Staphylococcus aureus, which produce SEB.

Biosensing Techniques↗

Development of amperometric horseradish peroxidase based biosensors for clozapine and for the screening of thiol compounds.

Two amperometric biosensors with immobilized horseradish peroxidase (HRP) were developed for the investigation of the clozapine drug oxidation and for thiols screening based on biosensor signal inhibition. The HRP was retained either in magnetized nanoporous silica microparticles (MMPs) or in a carbon paste (CP). The latter served for the carbon paste electrode while the MMPs were attracted in close proximity of a magnetized carbon electrode. The potential use of these configurations for drug oxidation and inhibition studies was illustrated by the enzymatic oxidation of clozapine (CLZ) in the presence of hydrogen peroxide. The biosensor signal corresponded to the electro-reduction of CLZ oxidation products namely a nitrenium ion (CLZox) generated by the enzyme HRP. Several thiols reactive towards CLZox were investigated and the biosensor signal inhibition (IC(50)) was comparatively determined. A protective effect of the nanoporous silica and carbon paste matrices towards HRP inactivation was inferred by comparing the biosensor inhibition results with those obtained with the free enzyme in solution.

Biosensing Techniques↗

Amperometric glucose biosensor based on multilayer films via layer-by-layer self-assembly of multi-wall carbon nanotubes, gold nanoparticles and glucose oxidase on the Pt electrode.

A novel amperometric glucose biosensor based on the nine layers of multilayer films composed of multi-wall carbon nanotubes (MWCNTs), gold nanoparticles (GNp) and glucose oxidase (GOD) was developed for the specific detection of glucose. MWCNTs were chemically modified with the H(2)SO(4)-HNO(3) pretreatment to introduce carboxyl groups which were used to interact with the amino groups of poly(allylamine) (PAA) and cysteamine via 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide cross-linking reaction, respectively. A cleaned Pt electrode was immersed in PAA, MWCNTs, cysteamine and GNp, respectively, followed by the adsorption of GOD, assembling the one layer of multilayer films on the surface of Pt electrode (GOD/GNp/MWCNTs/Pt electrode). Repeating the above process could assemble different layers of multilayer films on the Pt electrode. PBS washing was applied at the end of each assembly deposition for dissociating the weak adsorption. Film assembling and characterization were studied by transmission electron microscopy and quartz crystal microbalance, and properties of the resulting glucose biosensors were measured by electrochemical measurements. The marked electrocatalytic activity of Pt electrode based on multilayer films toward H(2)O(2) produced during GOD enzymatic reactions with glucose permitted effective low-potential amperometric measurement of glucose. Taking the sensitivity and selectivity into consideration, the applied potential of 0.35 V versus Ag/AgCl was chosen for the oxidation detection of H(2)O(2) in this work. Among the resulting glucose biosensors, the biosensor based on nine layers of multilayer films was best. It showed a wide linear range of 0.1-10mM glucose, with a remarkable sensitivity of 2.527 microA/mM, a detection limit of 6.7 microM estimated at a signal-to-noise ratio of 3 and fast response time (within 7s). Moreover, it exhibited good reproducibility, long-term stability and the negligible interferences of ascorbic acid, uric acid and acetaminophen. The study can provide a feasible approach on developing new kinds of oxidase-based amperometric biosensors, and can be used as an illustration for constructing various hybrid structures.

Biosensing Techniques↗

Nanotechnology and biosensors.

Nanotechnology is playing an increasingly important role in the development of biosensors. The sensitivity and performance of biosensors is being improved by using nanomaterials for their construction. The use of these nanomaterials has allowed the introduction of many new signal transduction technologies in biosensors. Because of their submicron dimensions, nanosensors, nanoprobes and other nanosystems have allowed simple and rapid analyses in vivo. Portable instruments capable of analyzing multiple components are becoming available. This work reviews the status of the various nanostructure-based biosensors. Use of the self-assembly techniques and nano-electromechanical systems (NEMS) in biosensors is discussed.

Biosensing Techniques↗

Determination of antibiotic residues and their interaction in milk with lactate biosensor.

Milk and dairy products are among the most important foodstuffs and the quality of raw milk is of significant importance from the point of view of human health. For rapid determination of chloramphenicol and penicillin residues in raw milk, lactate oxidase-based amperometric biosensor was used. The concentration of antibiotic residuals was determined by two characteristic reaction parameters, calculated from the biosensor transient response with the dynamic biosensor model. Both chloramphenicol and penicillin caused the decrease of the value of the kinetic parameter, but they changed the total signal change parameter in different ways. The shift of the combined total signal change parameter at the simultaneous presence of these antibiotics indicated their antagonistic effect. Due to the respiration process of bacteria in raw milk, the dynamics of the biosensor signal was different in warm and cold seasons. The respiration characteristics were added to the biosensor model as a negative linear time-depending factor. The reaction characteristic parameters, obtained with this complemented model, showed excellent alignment in different conditions and allowed to detect antibiotic residues and their interaction in raw milk.

Animals↗

Amperometric hydrogen peroxide biosensor based on the immobilization of HRP on nano-Au/Thi/poly (p-aminobenzene sulfonic acid)-modified glassy carbon electrode.

A novel hydrogen peroxide biosensor was fabricated for the determination of H(2)O(2). The precursor film was first electropolymerized on the glassy carbon electrode with p-aminobenzene sulfonic acid (p-ABSA) by cyclic voltammetry (CV). Then thionine (Thi) was adsorbed to the film to form a composite membrane, which yielded an interface containing amine groups to assemble gold nanoparticles (nano-Au) layer for immobilization of horseradish peroxidase (HRP). The electrochemical characteristics of the biosensor were studied by CV and chronoamperometry. The factors influencing the performance of the resulting biosensor were studied in detail. The biosensor responded to H(2)O(2) in the linear range from 2.6 x 10(-6) mol/L to 8.8 x 10(-3) mol/L with a detection limit of 6.4 x 10(-7) mol/L. Moreover, the studied biosensor exhibited good accuracy and high sensitivity. The proposed method was economical and efficient, making it potentially attractive for the application to real sample analysis.

Biosensing Techniques↗

Membrane entrapped Saccharomyces cerevisiae in a biosensor-like device as a generic rapid method to study cellular metabolism.

We describe a new, faster and convenient method to study some metabolic characteristics - by the successful application of immobilized yeast cells (S. cerevisiae) in a microbial biosensor-like device. Microbial biosensors consist of microorganisms immobilized on the surface of a membrane or in a gel, in close contact with a transducer. Almost all works published to date have used biosensors for analyses in which a concentration-related property of the external medium is measured. A different approach is presented here; we have successfully used S. cerevisiae and a carbon dioxide electrode as the main components of a biosensor-like device, used as a proof of concept, for a system useful to characterize metabolic parameters of the microbial cells immobilized on a carbon dioxide electrode. The biosensor-like device we are presenting allows us to calculate Michaelis-Menten parameters related to the kinetics of transport and degradation of several carbohydrates (i.e., glucose, fructose, galactose, sucrose and xylose, with K(m(app)) of 6.0, 5.8, 0.9, 2.0, and 147 mM, respectively), and the study of the kinetics of expression of non-constitutive proteins related to the transport and degradation of galactose.

Biosensing Techniques↗

Characterization of methods for determining sterilization efficacy and reuse efficiency of oxygen biosensor multiwell plates.

High-throughput screening (HTS) assays based upon fluorometric detection of oxygen consumption in microtiter plates were primarily developed for applications in drug discovery and ecotoxicology but have recently been adopted for use in microbial community-level physiological profiling assays (CLPP). The widespread use of oxygen biosensor systems for CLPP applications has, however, been hindered by the relatively high cost of oxygen biosensor reagent systems and limited access to microplate fluorometer instrumentation platforms. The ability to recycle and reuse oxygen biosensor system plates would expand their utilization for CLPP assays and other research applications in microbial ecology. Here, the efficacy and cost effectiveness of multiple procedures for sterilization of Oxygen Biosensor System (OBS; BD Biosciences) plates for reuse was evaluated. OBS plates were sterilized using ethylene oxide, ultraviolet radiation, and bleach treatments, then evaluated for biosensor response and plate life-cycle performance. Of the sterilization methods tested, ethylene oxide sterilization was most effective based on its low cost, high sterilization efficacy, and minimal impact upon OBS plate response.

Biosensing Techniques↗