PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Fractionation, Field Flow”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 325 records · Page 18Linked to original sources

Multidimensional Protein Corona Analysis Toward Predictive Nano-Bio Interface Design.

Nanoparticles entering biological fluids are rapidly coated by proteins and other biomolecules, converting their synthetic surfaces into biologically active nano-bio interfaces. These coronas regulate colloidal stability, immune recognition, cellular uptake, biodistribution, pharmacokinetics, cargo delivery, and toxicity. Yet a protein list obtained by mass spectrometry captures only part of this interface. Corona identity and function are also shaped by protein organization, binding stability, exchange dynamics, conformational changes, and molecular accessibility. Here, we discuss recent progress in protein corona isolation and analysis from a question-oriented analytical perspective, with emphasis on how centrifugation, magnetic recovery, affinity- or chemistry-enabled capture, chromatography, filtration, and field-flow fractionation (FFF) influence the fidelity, integrity, and comparability of recovered coronas. We then examine how proteomic profiling can be integrated with binding measurements, interfacial structural analysis and functional validation to distinguish descriptive corona signatures from biologically meaningful mechanisms. We further consider how biofluid composition, disease state, tissue interfaces and cellular environments remodel corona identity, presentation, and bioactivity. Finally, we argue that standardized reporting, computational modeling, and AI-enabled approaches are essential for converting protein corona datasets into reproducible and predictive knowledge that can guide the design of drug delivery systems and precision nanomedicines.

Protein Corona↗

Isopycnic Focusing Study of the Transient State in the Settling of Colloidal Particles

Various effective field forces can generate the concentrating flux of the colloidal particles. Centrifugal field forces were used in this work to study the kinetics of the transport phenomena and the effect of interparticle interactions of the model silica suspension. Isopycnic focusing of the colored density marker beads was used to visualize the evolution and final quasi-equilibrium shape of the density gradient formed in silica suspension. Many operational parameters and experimental conditions (thickness of the liquid layer in measuring cells, intensity of the centrifugal forces, average concentration of the silica particles, and geometrical shape of the measuring cells) were tested to evidence their influence on the concentration and density gradient formation. The main objective was to apprehend the processes governing isoperichoric focusing in thin layers under model static conditions which is necessary for the optimization of isoperichoric focusing field-flow fractionation dynamic experiments carried out under conditions of hydrodynamical flow as an active factor of the separation by focusing effect. The experimental results were compared with the hypothetical model of noninteracting particles to demonstrate the effect of the actual interparticle interactions.

Journal Article↗

Mucin Adsorption to Hydrophobic Surfaces.

The adsorption isotherm of bovine submaxillary gland mucin (BSM) onto a hydrophobic polystyrene surface was determined by using the solution depletion method, in which mucin concentrations were analyzed by amino acid analysis. Adsorption and desorption kinetics of BSM onto hydrophobic polystyrene surfaces were also studied by the solution depletion method, in which mucin solution concentrations were determined by measuring UV absorbance at a wavelength of 280 nm and by a BCA colorimetric assay with final calibration by amino acid analysis. From the adsorption isotherm, we found that the saturated surface concentration (Gamma(max)) was 2.3 mg/m(2), and the adsorption constant (K) was calculated as 0.099 (ml/mg). By using a Langmuir adsorption model and nonlinear fitting, kinetics parameters, k(on) and k(off), were found to be 8.13x10(-3) cm(3) mg(-1) s(-1) and 5.67x10(-4) s(-1), respectively. The coating was found to be very stable with very limited desorption (less than 2%) from a long-term observation (28 h). The mucin coating layer thickness was investigated by several analytical techniques: flow field-flow-fractionation, photon correlation spectroscopy, scanning electron microscopy, and atomic force microscopy. The thickness was measured as 4-5 nm, from which a monolayer coating was concluded. Finally, the weight average molecular weight of purified bovine submaxillary gland mucin (BSM) was determined as 1.6x10(6) Da by using static light scattering. Copyright 2000 Academic Press.

Journal Article↗

Transport Phenomena and Electrode Reactions Generated by an Electric Field in Colloidal Silica.

The kinetics of transport phenomena generated by an electric field and leading to the formation of density gradients in suspensions of charged colloidal silica were studied by using various electrodes. The rate of approach to a steady-state density gradient was found to be much higher when using metallic electrodes (Cu, Fe, and Pt) in comparison with graphite (C) electrodes. Nevertheless, the initial rate with C electrodes was substantially increased by the addition of hydroquinone-quinone because the redox reactions, necessary for electrode-electrolyte current transfer, occur at lower potential compared with the electrolysis of water. On the other hand, the products of oxidation of hydroquinone which accumulate in the system bring about an important decrease of the zeta potential of silica particles and progressive deceleration of their electrophoretic mobility. A detailed study was carried out, by using thin-layer isoperichoric focusing, UV-vis spectrophotometry, and voltamperometry, to explain the observed phenomena which can interfere in electric polarization or focusing field-flow fractionation. Copyright 2000 Academic Press.

Journal Article↗

3D characterization of natural colloids by FlFFF-MALLS-TEM.

Understanding the role of colloids in the environment needs a more complete characterization of their size and shape than the usually used hydrodynamic diameter. A novel methodology to determine three dimensional description of colloids has been successfully experimented in this work by coupling Flow-Field Flow Fractionation (FlFFF) to Multi Angle Laser Light Scattering (MALLS), and Transmission Electron Microscope (TEM). This methodology was evaluated for a soil colloidal sample. Results show that, the particles surface areas determined by FlFFF-MALLS-TEM, are 3-4 times greater than those calculated using the hydrodynamic diameter determined by FlFFF. Further, results indicated that, the surface area/volume values are 3-5 times greater than those calculated based on the hydrodynamic diameter. Therefore, a correction factor must be applied when the particle surface area is calculated from the hydrodynamic diameter determined by FlFFF.

Journal Article↗

Rapid swelling of a CHO-K1 aspartate/glutamate transport mutant in hypo-osmotic medium.

Two Chinese hamster ovary cell (CHO-K1) mutants selected for defective glutamate transport via system X-AG are also highly permeable to small neutral molecules. Light microscopy demonstrated that exposure of one of these mutants, Ed-A1, to hypo-osmotic medium led to extremely rapid swelling, presumably due to increased water flux. When placed in 20% saline, Ed-A1 cells swelled to three times their original volume within 15 sec, a sixfold larger increase than parental CHO-K1. In spite of this rapid volume increase, mutant and wild-type cells remained viable for 20 min in dilute saline. A regulatory volume decrease in Ed-A1, and the continual swelling of CHO-K1, resulted in the two cells achieving equal size after 5 min in 20% saline. The time course of these volume changes permitted analysis of large numbers of cells by a hydrodynamic technique, steric field flow fractionation (FFF). Steric FFF demonstrated the expected inhibition of osmotic swelling of human erythrocytes by the mercurial, p-chloromercuribenzenesulfonic acid (PCMBS). However, PCMBS increased the apparent swelling rate of Ed-A1 and CHO-K1, suggesting that an aquaporin-like molecule is not responsible for any significant fraction of the water fluxes into either line. PCMBS also strongly inhibited aspartate transport by system X-AG. By taking advantage of their different swelling rates in hypotonic medium, steric FFF can separate mixtures of CHO-K1 and Ed-A1.

4-Chloromercuribenzenesulfonate↗

Separation of B and T lymphocytes by a hybrid field-flow fractionation/adhesion chromatography technique.

A hybrid of the techniques of cellular adhesion chromatography and field-flow fractionation has been used for the effective separation of rat mesenteric B and T lymphocytes with nearly complete recovery of both cell species. Use of this hybrid technique also allows the relative binding strengths of cells to biomaterials and other surfaces to be rapidly and simply estimated. For the copolymer surface used here, B cells appear to bind with a force five times greater than T cells.

Animals↗

Surface modification of nanoparticles by PEO/PPO block copolymers to minimize interactions with blood components and prolong blood circulation in rats.

The biological fate of injected foreign particles is believed to be closely related to their interactions with blood plasma proteins and cells. In order to verify this correlation, we have quantitatively measured protein adsorption and blood retention profiles in rats by using model polystyrene latex nanoparticles. The in vitro interactions of these non-biodegradable particles with plasma proteins and whole blood can be altered by modifying their surfaces with a family of amphiphilic polymeric surfactants, PEO/PPO Pluronic or Tetronic block copolymers. Protein adsorption was measured by several techniques, including photon correlation spectroscopy, centrifugation, high performance liquid chromatography and field-flow fractionation. Pluronic F108 and Tetronic 908 and 1508 copolymers (with PEO terminal block MWPEO > 5000, PPO middle block MWPPO > 3000, and HLB values > 24) were shown to be the most effective surface modifiers in reducing adsorption of plasma proteins on the particles. Minimum interaction of coated particles with whole blood was also observed by optical microscopy. The blood circulation half-life of the particles injected in rats was increased from 20 min to 13 h when the latex particles (75 nm) were precoated with these block copolymers. These results suggest that nanoparticles designed for use as injectable drugs or drug carriers should display similar surface characteristics provided by such amphiphilic surface modifiers.

Adsorption↗

Microfluidic approaches to malaria detection.

Microfluidic systems are under development to address a variety of medical problems. Key advantages of micrototal analysis systems based on microfluidic technology are the promise of small size and the integration of sample handling and measurement functions within a single, automated device having low mass-production costs. Here, we review the spectrum of methods currently used to detect malaria, consider their advantages and disadvantages, and discuss their adaptability towards integration into small, automated micro total analysis systems. Molecular amplification methods emerge as leading candidates for chip-based systems because they offer extremely high sensitivity, the ability to recognize malaria species and strain, and they will be adaptable to the detection of new genotypic signatures that will emerge from current genomic-based research of the disease. Current approaches to the development of chip-based molecular amplification are considered with special emphasis on flow-through PCR, and we present for the first time the method of malaria specimen preparation by dielectrophoretic field-flow-fractionation. Although many challenges must be addressed to realize a micrototal analysis system for malaria diagnosis, it is concluded that the potential benefits of the approach are well worth pursuing.

Electrophoresis↗

Liposome-encapsulated actin-hemoglobin (LEAcHb) artificial blood substitutes.

A new approach to enhance the circulation persistence of liposomes has been applied to develop liposome-encapsulated actin-hemoglobin (LEAcHb) dispersions as potential blood substitutes by introducing an actin matrix into the liposome aqueous core. Asymmetric flow field-flow fractionation coupled with multi-angle static light scattering was used to study the shape, size distribution, and encapsulation efficiency of liposome-encapsulated hemoglobin (LEHb) and LEAcHb dispersions. By polymerizing monomeric actin into filamentous actin inside the liposome aqueous core, LEAcHb particles transformed into a disk-like shape. We studied the effect of an encapsulated actin matrix on the size distribution, hemoglobin (Hb) encapsulation efficiency, oxygen affinity, and methemoglobin (MetHb) level of LEAcHb dispersions, and compared them with plain LEHb dispersions (without actin). LEHb, and LEAcHb dispersions extruded through 400 nm membranes were injected into rats and it was observed that LEAcHb dispersions with 1mg/mL of actin enhanced the circulatory half-life versus LEHb dispersions. The circulatory characteristics of empty PEGylated and non-PEGylated actin-containing liposomes (without Hb) were studied as controls for the LEHb and LEAcHb dispersions in this paper, which displayed maximum circulatory half-lives greater than 72 h. Taken together the results of this study supports our hypothesis that a lipid membrane supported by an underlying actin matrix will extend the circulatory half-life of LEHb dispersions.

Actins↗

Surface attachment of nanoparticles using oligonucleotides.

Colloidal polymer particles are widely used in a variety of applications ranging from chromatography to surface modified bioreactors in protein arrays. In the present study, surface attachment of polystyrene particles to a polystyrene substrate has been performed using oligonucleotide hybridization. Thiolated complementary oligomers of cytosine and guanine have been covalently coupled to a pyridyl disulphide (PDS) modified polyethyleneglycol tether, forming part of a triblock copolymer which is adsorbed to the polystyrene surfaces via hydrophobic polypropylene oxide center blocks. The ability to withstand shear forces was studied using a laminar flow cell and the uptake of oligomers on the particles was quantified using two complementary techniques: UV-spectroscopy and sedimentation field flow fractionation. The possibility to tether particles in a flow cell suitable for practical use in e.g. a FIA-system is demonstrated.

Binding Sites↗

SdFFF monitoring of cellular apoptosis induction by diosgenin and different inducers in the human 1547 osteosarcoma cell line.

Apoptosis is one of the most important phenomena of cellular biology. Sedimentation field flow fractionation (SdFFF) has been described as an effective tool for cell separation, respecting integrity and viability. Because SdFFF takes advantage of intrinsic properties of eluted cells (size, density, shape or rigidity), we investigated the capacity of SdFFF in monitoring the early and specific biophysical modifications which occurred during cellular apoptosis induction. Then, we used, as an in vitro cellular apoptosis model, the association between human 1547 osteosarcoma cells and diosgenin, a plant steroid known to induce apoptosis. Four other molecules were studied: hecogenin, tigogenin, staurosporine and MG132. Our results demonstrated a correlation between SdFFF elution profile changes (peak shape modification and retention ratio evolution) and effective apoptosis induction. For the first time, we demonstrated that SdFFF could be used to monitor apoptosis induction as early as 6 h incubation, suggesting different applications such as screening series of molecules to evaluate their ability to induce apoptosis, or sorting apoptotic cells to study apoptosis pathway.

Apoptosis↗

Interaction of trace elements in acid mine drainage solution with humic acid.

The release of metal ions from a coal mining tailing area, Lamphun, Northern Thailand, is studied by leaching tests. Considerable amounts of Mn, Fe, Al, Ni and Co are dissolved in both simulated rain water (pH 4) and 10 mg L(-1) humic acid (HA) solution (Aldrich humic acid, pH 7). Due to the presence of oxidizing pyrite and sulfide minerals, the pH in both leachates decreases down to approximately 3 combined with high sulfate concentrations typical to acid mine drainage (AMD) water composition. Interaction of the acidic leachates upon mixing with ground- and surface water containing natural organic matter is simulated by subsequent dilution (1:100; 1:200; 1:300; 1:500) with a 10 mg L(-1) HA solution (ionic strength: 10(-3) mol L(-1)). Combining asymmetric flow field-flow fractionation (AsFlFFF) with UV/Vis and ICP-MS detection allows for the investigation of metal ion interaction with HA colloid and colloid size evolution. Formation of colloid aggregates is observed by filtration and AsFlFFF depending on the degree of the dilution. While the average HA size is initially found to be 2 nm, metal-HA complexes are always found to be larger. Such observation is attributed to a metal induced HA agglomeration, which is found even at low coverage of HA functional groups with metal ions. Increasing the metal ion to HA ratio, the HA bound metal ions and the HA entities are growing in size from <3 to >450 nm. At high metal ion to HA ratios, precipitation of FeOOH phases and HA agglomeration due to colloid charge neutralization by complete saturation of HA complexing sites are responsible for the fact that most of Fe and Al precipitate and are found in a size fraction >450 nm. In the more diluted solutions, HA is more relevant as a carrier for metal ion mobilization.

Coal Mining↗

Computer simulation of particle separation based on non-equilibrium swelling.

Steric/hyperlayer field-flow fractionation (FFF) is an established analytical technique for separating and characterizing particles in the 1-100 microns diameter range. The separation can be based on differences in size, density, shape and mechanical properties of the particles. In the course of an analysis of the water transporter system of Chinese hamster ovary (CHO) cells and one of their high permeability mutants, the first successful attempt was made to use the steric/hyperlayer FFF system for the purpose of separating particles based on a time-dependent property, namely, the differential swelling of the two cell types. The present study was undertaken to simulate numerically the separation and suggest selection of operating conditions to minimize repetitive experiments. The computer simulation was developed using Maple V, a symbolic computing environment. It is shown that the model is able to predict an optimal velocity of carrier buffer that maximizes resolution. Predicted velocity/resolution pairs are in good agreement with available experimental data. Empirical models for the lift forces encountered in such FFF experiments, and for the zone broadening observed in work with cell sized particles, form the basis for this model.

Animals↗

The effect of surface coatings on the association of orthophosphate with natural colloids.

A new method has been utilised for the characterisation of natural particle surface coatings. The method involves the use of sedimentation field-flow fractionation (SdFFF), radiolabelling and inductively coupled plasma-high resolution mass spectrometry (ICP-HR MS) techniques to study the effect of colloidal surface coatings on the adsorptive behaviour of orthophosphate. Colloidal river sediment and soil samples were chemically treated in an attempt to selectively remove metal hydroxyoxides and natural organic matter. The samples were then radiolabelled with 33PO4(3-) and analysed by SdFFF to determine the surface adsorption density (SAD) of orthophosphate as a function of particle size. The SdFFF unit was directly coupled to an ICP-HR MS to determine the chemical composition of the colloidal samples as a function of particle size. Element concentration/UV detector signal and element atomic molar ratios were plotted against particle size, and the trends used in the interpretation of SAD distribution (SADD) changes for the samples were studied. In general, non-constant trends in the orthophosphate SADDs were found, except for the river sediment treated with hydroxylamine hydrochloride. The results indicated that, in the soil sample studied, the Mn oxide coating was a dominant factor in determining phosphorus adsorption. This method could also be applicable to other industrial or similar samples.

Adsorption↗

Optimizing fluorescence detection in chemical separations for analyte bands traveling at different velocities.

In many separation techniques, such as field flow fractionation, liquid chromatography, and electrophoresis, chemical species form bands that migrate at distinct velocities. If these bands are to be quantified on-line using a shot-noise-limited detection system, then attention must be given to the data-digitization rate and to the removal rate of molecules from the analyte pool as a result of the detection process. A theory is developed for calculating the signal-to-noise ratio under such conditions, and it is specialized to the case of fluorescence detection in capillary electrophoresis. Using standard detection procedures in which the data-digitization rate and excitation intensity remain constant for the duration of a separation, detection sensitivity can vary by more than a factor of five for bands that arrive at the detection zone between migration times tau fast and 10 tau fast, where tau fast is the time after the start of the separation that the fastest migrating band arrives at the detection zone. To compensate for different band velocities, both the data-digitization rate and the excitation intensity must be decreased as separation time (tau) increases by the factor tau fast/tau. Only when these corrections are made can uniform sensitivity with the highest possible signal-to-noise ratio be achieved for each peak. These predictions are experimentally tested and compare favorably to observations.

Electrophoresis↗

Coronaspray nebulization and ionization of liquid samples for ion mobility spectrometry.

Ion mobility spectrometry after electrospray nebulization and ionization was investigated as a method for the detection of components dissolved in liquids. While electrosprary operating conditions proved promising, greater sensitivity was achieved when the electric potential applied to the sample introduction needle was increased above breakdown potential and a corona discharge was established. Passing the liquid through the corona discharge established a "coronaspray" that efficiently nebulized and ionized the solvent and analytes. In this initial investigation of coronaspray ion mobility spectrometry (CIMS), ion current as a function of potential, temperature, and liquid flow rate was studied; several IMS spectra were obtained; and a continuous monitoring mode of operation was demonstrated. The results from this study indicated that CIMS has potential as a versatile and sensitive detection method for a variety of analytical procedures involving liquid flowing streams such as flow injection analysis, liquid chromatography, capillary zone electrophoresis, and field flow fractionation.

Electrochemistry↗

Size characterization of bentonite colloids by different methods.

The size and shape of colloids released from a natural bentonite into a low-mineralized groundwater are investigated using various colloid characterization methods. For the applied methods such as atomic force microscopy (AFM), laser-induced breakdown detection (UBD), photon correlation spectroscopy (PCS), and flow field-flow fractionation coupled to ICP-mass spectrometric detection (FFFF-ICPMS), the respective raw size data have to be corrected in order to consider chemical composition and shape of the colloids as well as instrumental artifacts. Noncontact mode AFM of the bentonite colloids shows disklike shapes of stacked smectite platelets with a mean height-to-diameter proportion (aspect ratio) of approximately 1/10. A broad particle number size distribution is determined by image processing with a mean particle diameter of 73 nm. In agreement with AFM, a broad size distribution is also found by PCS and FFFF-ICPMS. Likewise, mean particle sizes found by LIBD (67 +/- 13 nm) and FFFF-ICPMS (maximum in the number size distribution, approximately 70 nm) are in fair agreement with the AFM data. Somewhathigher values are obtained by PCS, where mean particle diameters of the intensity-weighted size distributions of larger than 200 nm are found (depending on the algorithm used for data processing). The influence of the disklike particle shape on the results of the individual methods is discussed. As a conclusion, the application of different colloid characterization methods is a prerequisite to get complementary information about colloid size and shape, which is essential for the understanding of natural colloidal systems.

Algorithms↗