PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Protein Array Analysis”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 649 records · Page 36Linked to original sources

High-throughput kinase assays with protein substrates using fluorescent polymer superquenching.

BACKGROUND: High-throughput screening is used by the pharmaceutical industry for identifying lead compounds that interact with targets of pharmacological interest. Because of the key role that aberrant regulation of protein phosphorylation plays in diseases such as cancer, diabetes and hypertension, kinases have become one of the main drug targets. With the exception of antibody-based assays, methods to screen for specific kinase activity are generally restricted to the use of small synthetic peptides as substrates. However, the use of natural protein substrates has the advantage that potential inhibitors can be detected that affect enzyme activity by binding to a site other than the catalytic site. We have previously reported a non-radioactive and non-antibody-based fluorescence quench assay for detection of phosphorylation or dephosphorylation using synthetic peptide substrates. The aim of this work is to develop an assay for detection of phosphorylation of chemically unmodified proteins based on this polymer superquenching platform. RESULTS: Using a modified QTL Lightspeed assay, phosphorylation of native protein was quantified by the interaction of the phosphorylated proteins with metal-ion coordinating groups co-located with fluorescent polymer deposited onto microspheres. The binding of phospho-protein inhibits a dye-labeled "tracer" peptide from associating to the phosphate-binding sites present on the fluorescent microspheres. The resulting inhibition of quench generates a "turn on" assay, in which the signal correlates with the phosphorylation of the substrate. The assay was tested on three different proteins: Myelin Basic Protein (MBP), Histone H1 and Phosphorylated heat- and acid-stable protein (PHAS-1). Phosphorylation of the proteins was detected by Protein Kinase Calpha (PKCalpha) and by the Interleukin -1 Receptor-associated Kinase 4 (IRAK4). Enzyme inhibition yielded IC50 values that were comparable to those obtained using peptide substrates. Statistical parameters that are used in the high-throughput community to determine assay robustness (Z'-value) demonstrate the suitability of this format for high-throughput screening applications for detection of inhibitors of enzyme activity. CONCLUSION: The QTL Lightspeed protein detection system provides a simple mix and measure "turn on" assay for the detection of kinase activity using natural protein substrates. The platform is robust and allows for identification of inhibitors of kinase activity.

Adaptor Proteins, Signal Transducing↗

Identification of proteins regulated by PACAP in PC12 cells by 2D gel electrophoresis coupled to mass spectrometry.

The rat pheochromocytoma PC12 cell line has been widely used as a model to study neuronal differentiation. In particular, after serum depletion, PC12 cells stop to proliferate and undergo apoptosis. Under such conditions, treatment with pituitary adenylate cyclase-activating polypeptide (PACAP) promotes cell survival and induces neurite outgrowth. The identification of the proteins regulated by PACAP in PC12 cells under apoptotic conditions should provide valuable information concerning the mechanisms controlling neuronal cell survival and differentiation. To this aim, PC12 cells cultured in serum-free medium were treated with PACAP (10(-7) M), proteins were extracted, separated by two-dimensional gel electrophoresis (2-DE), and identified by MALDI-ToF mass spectrometry. The comparison between 16 2-DE maps led to the characterization of 110 proteins regulated by PACAP among which 22 have been identified by automatic query of the Mascot, Aldente, and Profound servers with the ProGeR-CDD database. Seventy-six percent of these proteins, including the p17 subunit of caspase-3, the heat shock protein hsp60, and the GTPase ran were found to be repressed whereas the others notably hsp27, tubulin beta-5, and calmodulin were overexpressed. Investigation of the putative functions indicated that some of the proteins regulated by PACAP and identified in the present article could control cell survival or differentiation.

Animals↗

Novel biomarkers of human growth hormone action from serum proteomic profiling using protein chip mass spectrometry.

CONTEXT: The detection of exogenous human GH (hGH) administration in athletes poses unique analytical problems, because its short circulating half-life provides only a brief opportunity to detect the administered hormone above endogenous levels. Measurement of novel GH-regulated serum protein biomarkers might provide an indirect method to detect exogenous GH. OBJECTIVE: The objective of this study was to identify new serum biomarkers of GH administration using proteomic profiling. DESIGN: Sera from a previously reported, double-blind, placebo-controlled GH administration trial were analyzed by protein chip mass spectrometry. SETTING: The study was performed at clinical research centers. SUBJECTS: Sixty healthy subjects, aged 18-40 yr, who were not elite athletes, were studied. INTERVENTIONS: Placebo or recombinant hGH treatment (0.1 or 0.2 IU/kg.d; 20 subjects/group) was administered for 4 wk, followed by an 8-wk washout period. MAIN OUTCOME MEASURES: Protein mass profiles were determined on immobilized Cu(2+) chips on d 0 and 21 of GH administration, and multivariate analysis was used to classify subjects into GH and placebo administration groups. RESULTS: When assessed by cross-validation, the classification performance of classifiers based on multivariate analysis of several GH-regulated peaks performed no better than classifiers based on the single best peak. This peak, a prominent biomarker of 15.1 kDa, was purified and identified as hemoglobin alpha-chain. The time course of the GH response of this biomarker is similar to that of other GH-dependent markers, such as IGF-I. CONCLUSION: This study demonstrates that protein mass profiling is an effective tool for the detection of GH administration and suggests that measurement of hemoglobin alpha-chain may have utility as a novel serum biomarker of GH action.

Adolescent↗

Interaction of protein-bound polysaccharide (PSK) with smooth muscle myosin regulatory light chain.

The interaction of a protein-bound polysaccharide (PSK) isolated from Basidiomycetes with smooth muscle myosin components was evaluated by limited digestion, urea/glycerol gel electrophoresis, affinity chromatography and overlay assay using a peptide array. PSK was bound to the regulatory light chain (RLC) of myosin, but not to the essential light chain. The binding to PSK was definitely observed for unphosphorylated RLC, compared to phosphorylated one. From the amino acid sequence of the RLC, 490 peptides were synthesized on a cellulose membrane. Overlay assays showed that the PSK-binding on the molecule of RLC were localized in the N- and C-terminal basic regions and these sites were conserved in RLC from the human smooth muscle and nonmuscle cells.

Amino Acid Sequence↗

Protein arrays from cDNA expression libraries.

This chapter describes the production of a cDNA expression library from human fetal brain, the construction of a high-density protein array from such a library, and two applications to screen the array for binding proteins. After producing the library and decollating the expression clones, one can pick thousands of expression clones with a laboratory robot and can deposit them into microtiter plates in an ordered manner. Such ordered clone libraries are the starting material for the construction of a high-density protein array. This array is constructed by spotting the expression clones onto a protein-binding membrane. Following cell growth and induction of protein expression on the membrane, the cell spots are lysed and their recombinant protein immobilized on the membrane. The so-constructed array carries thousands of proteins without the need to clone, express, and spot individual proteins. Such arrays allow one to screen for numerous protein functions in a high-throughput manner.

Amino Acid Sequence↗

Generation of protein in situ arrays by DiscernArray technology.

A cell-free DiscernArray technology is described for making protein arrays directly from polymerase chain reaction deoxyribonucleic acid (PCR DNA) fragments. In this method, individual tagged proteins are synthesized in a cell-free system on a tag-binding surface, such that the tagged proteins are immobilized on the surface as they are produced. This technology is particularly useful for arraying proteins/domains that cannot be functionally produced by heterologous expression or for which the cloned DNA is not available. Protein arrays of single-chain antibodies, ligand-binding domains, and enzymes have been successfully generated by this method.

Cell-Free System↗

Processing of photoaptamer microarrays.

Photoaptamers are single-stranded nucleic acids selected for their high affinity to specific proteins of interest. Photoaptamer microarrays capture and quantify proteins from complex samples using a unique protocol that leverages both high-affinity capture with covalent retention of analytes. The initial capture of proteins from solution is similar to the well-known antibody capture, but the "secondary binding event" affected by photoaptamers is a covalent crosslink between the photoaptamer capture agent and the protein analyte. The nature of this specific covalent reaction allows a unique microarray processing that is described in detail in this chapter.

Cross-Linking Reagents↗

A protein microarray ELISA for screening biological fluids.

Protein microarrays permit the simultaneous measurement of many proteins in a small sample volume and therefore provide an attractive approach for the quantitative measurement of proteins in biological fluids, including serum. This chapter describes a microarray enzyme-linked immunosorbent assay (ELISA). Capture antibodies are immobilized onto a glass surface; the covalently attached antibodies bind a specific antigen from a sample overlaying the array. A second, biotinylated antibody that recognizes the same antigen as the first antibody, but at a different epitope, is then used for detection. Detection is based on an enzymatic signal-enhancement method known as tyramide signal amplification (TSA). By coupling a microarray-ELISA format with the signal amplification of tyramide deposition, the assay sensitivity is as low as sub-pg/mL.

Amides↗

Protein-domain microarrays.

Protein domains are independently folded regions of proteins that are often involved in protein-protein interactions. They are good candidates for the generation of protein microarrays because of their small size, their globular structures, and the fact that they are the protein-interacting workhorses of the cell. In addition, arrayed recombinant protein domains retain much of their binding specificity. Such microarrays can be probed with other recombinant proteins or fluorescently labeled peptides to identify potential binding partners and also determine how posttranslational modifications influence specific interactions. Thus, protein domains provide us with a system-oriented array that is focused on elucidating signal transduction pathway specificity and regulation.

Animals↗

SH3 domain protein-binding arrays.

First identified as part of the Rous sarcoma oncogene product Src, SH3 (Src Homology 3) domains play an important role in intercellular communication and intracellular signal transduction. A high-throughput assay for ligand binding to SH3 domains--SH3 domain proteins immobilized on a membrane--allows rapid visualization of numerous SH3 domain protein-protein interactions with no expensive equipment or radioactivity required. Once the array is constructed or obtained commercially, the procedure is straightforward: The protein of interest is cloned into a fusion-tagged expression vector and expressed in bacteria, the prepared bacterial extract is incubated with the array membrane, and the signal is measured using a chemiluminescence detection system.

Humans↗

Site-specific peptide immobilization strategies for the rapid detection of kinase activity on microarrays.

The massive throughput offered by array-based technologies can only be realized with the development of equally powerful strategies that offer reproducible consistency. The competence of arrays and efficacy of screening come under scrutiny, with most existing immobilization schemes that do not site-specifically ligate peptides on the arrays. Thus, it is crucial in array-based experiments to orientate peptides in an ordered and uniform fashion. Two new approaches were developed for the directed immobilization of peptides on a microarray, by exploiting measures involving native chemical ligation reactions as well as biotin-streptavidin interactions. This makes it possible to stably immobilize peptides in a consistent manner and in a predetermined orientation on the microarray. The first scheme employs glass slides that are functionalized with avidin for attachment of terminally biotinylated peptides. The second uses slides containing thioester moieties to ligate N-terminal cysteine containing peptides. The authors successfully immobilized peptides on chip using these strategies, and, in extending their method to the study of kinase activity on microarrays, they also developed a novel detection scheme that abrogates the dependence on traditional radioactivity-based kinase screening assays. This method employs fluorescently labeled antiphosphoserine and antiphosphotyrosine antibodies in assessing and monitoring kinase activity on arrays. The above methodologies provide for a fast and sensitive approach with which to conveniently assess kinase activity using peptide microarrays.

Antibodies↗

Surface plasmon resonance imaging measurements of protein interactions with biopolymer microarrays.

The surface-sensitive optical technique of surface plasmon resonance (SPR) imaging is an ideal method for the study of affinity binding interactions of unlabeled biological molecules in a multiplexed format. This approach has been widely applied to monitor DNA-DNA, DNA-RNA, peptide-protein, and protein-protein interactions as well as surface enzyme reactions. The success of SPR imaging measurements relies on the robust attachment of biomolecules in an array format. In this chapter, we introduce two different surface attachment chemistries that covalently immobilize DNA and peptides onto gold surfaces through the modification of self-assembled alkanethiol monolayers. Array fabrication approaches for the creation of individually addressable elements through the use of either gold dot patterns or polydimethylsiloxane (PDMS) microchannels are detailed. The utility of SPR imaging for the study of protein interactions is demonstrated with two biological systems: the binding of response regulator proteins, VanR and OmpR, onto a DNA array, and the interaction of S protein with an array of S-peptide variants. Furthermore, the application of real-time SPR imaging to the multiplexed determination of S-protein adsorption/desorption kinetics is described.

Bacterial Proteins↗

RCA-enhanced protein detection arrays.

There are many instances in which it is desirable to generate profiles of the relative abundance of a multiplicity of protein species. Examples include studies in embryonic development, immunobiology, drug responses, cancer biology, biomarkers, and so on. Microarray formats provide a convenient, high-throughput vehicle for generating such profiles, and the repertoire of proteins that can be measured is growing continuously as larger panels of specific antibodies become available. Here we describe methods for the use of antibody microarrays, whereby the detection of specifically bound antigens is enhanced by rolling circle amplification (RCA). RCA-enhanced protein detection on antibody microarrays provides a means for rapid protein profiling at high sensitivity. The set of RCA reagents remains unchanged for different microarray formats and compositions, and signal readout is performed using standard fluorescent dyes and scanners. The method is sensitive enough for the most challenging applications, such as the detection of low-abundance components of human serum.

Animals↗

Conformational change of bacteriorhodopsin quantitatively monitored by microcantilever sensors.

Bacteriorhodopsin proteoliposomes were used as a model system to explore the applicability of micromechanical cantilever arrays to detect conformational changes in membrane protein patches. The three main results of our study concern: 1), reliable functionalization of micromechanical cantilever arrays with proteoliposomes using ink jet spotting; 2), successful detection of the prosthetic retinal removal (bleaching) from the bacteriorhodopsin protein by measuring the induced nanomechanical surface stress change; and 3), the quantitative response thereof, which depends linearly on the amount of removed retinal. Our results show this technique to be a potential tool to measure membrane protein-based receptor-ligand interactions and conformational changes.

Bacteriorhodopsins↗