PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 739 records · Page 41Linked to original sources

Using microfluidics to observe the effect of mixing on nucleation of protein crystals.

This paper analyzes the effect of mixing on nucleation of protein crystals. The mixing of protein and precipitant was controlled by changing the flow rate in a plug-based microfluidic system. The nucleation rate inversely depended on the flow rate, and flow rate could be used to control nucleation. For example, at higher supersaturations, precipitation happened at low flow rates while large crystals grew at high flow rates. Mixing at low flow velocities in a winding channel induces nucleation more effectively than mixing in straight channels. A qualitative scaling argument that relies on a number of assumptions is presented to understand the experimental results. In addition to helping fundamental understanding, this result may be used to control nucleation, using rapid chaotic mixing to eliminate formation of precipitates at high supersaturation and using slow chaotic mixing to induce nucleation at lower supersaturation.

Crystallization↗

Real-time sizing of nanoparticles in microfluidic channels using confocal correlation spectroscopy.

This Communication reports real-time sizing of nanoparticles in microfluidic systems using confocal correlation spectroscopy (CCS). CCS can be used to measure the size of both fluorescent and nonfluorescent particles at low concentrations (<nanomolar) and in small volumes (<femtoliters). With advances in nonfluorescent modes of single-particle and single-molecule detection, we anticipate CCS will find broad use in the real-time measurements of nanoparticles and macromolecules.

Fluorescent Dyes↗

Electrowetting dynamics of microfluidic actuation.

When voltage is suddenly applied to vertical, parallel dielectric-coated electrodes dipped into a liquid with finite conductivity, the liquid responds by rising up to reach a new hydrostatic equilibrium height. On the microfluidic scale, the dominating mechanism impeding this electromechanically induced actuation appears to be a dynamic friction force that is directly proportional to the velocity of the contact line moving along the solid surface. This mechanism has its origin in the molecular dynamics of the liquid coming into contact with the solid surface. A simple reduced-order model for the rising column of liquid is used to quantify the magnitude of this frictional effect by providing estimates for the contact line friction coefficient. Above some critical threshold of voltage, the electromechanical force is clamped, presumably by the same mechanism responsible for contact angle saturation and previously reported static height-of-rise limits. The important distinction for the dynamic case is that the onset of the saturation effect is delayed in time until the column has risen more than about halfway to its static equilibrium height.

Algorithms↗

Effect of flow and surface conditions on human lymphocyte isolation using microfluidic chambers.

Phenotypically pure subpopulations of lymphocytes can provide valuable insights into the immune response to injury and disease. The isolation of these subpopulations presents unique challenges, particularly when preprocessing incubation to attach fluorescent or antibody tags is to be minimized. This paper examines the separation of T and B lymphocytes from mixtures using microfluidic chambers coated with antibodies, focusing on flow conditions and surface chemistry. The adhesion of both cell types decreases as shear stress increases irrespective of the surface chemistry. The incorporation of poly(ethylene glycol) chains along with the antibodies on the chamber surface is shown to significantly improve the reproducibility of cell adhesion and is thus an important part of the overall system design. Furthermore, this technique is shown to be an effective way of isolating highly pure subpopulations of lymphocytes from model mixtures, even when the target cell concentration is low.

Antibodies↗

Tailoring the surface properties of poly(dimethylsiloxane) microfluidic devices.

Poly(dimethylsiloxane) (PDMS) is an attractive material for microelectrophoretic applications because of its ease of fabrication, low cost, and optical transparency. However, its use remains limited compared to that of glass. A major reason is the difficulty of tailoring the surface properties of PDMS. We demonstrate UV grafting of co-mixed monomers to customize the surface properties of PDMS microfluidic channels in a simple one-step process. By co-mixing a neutral monomer with a charged monomer in different ratios, properties between those of the neutral monomer and those of the charged monomer could be selected. Mixtures of four different neutral monomers and two different charged monomers were grafted onto PDMS surfaces. Functional microchannels were fabricated from PDMS halves grafted with each of the different mixtures. By varying the concentration of the charged monomer, microchannels with electrophoretic mobilities between +4 x 10(-4) cm2/(V s) and -2 x 10(-4) cm2/(V s) were attainable. In addition, both the contact angle of the coated surfaces and the electrophoretic mobility of the coated microchannels were stable over time and upon exposure to air. By carefully selecting mixtures ofmonomers with the appropriate properties, it may be possible to tailor the surface of PDMS for a large number of different applications.

Dimethylpolysiloxanes↗

Continuous fabrication of biocatalyst immobilized microparticles using photopolymerization and immiscible liquids in microfluidic systems.

We report a novel technique for manufacturing polymeric microparticles containing biocatalysts by the behavior of immiscible liquids in microfluidic systems and in situ photopolymerization. The approach utilizes a UV-polymerizable hydrogel/enzyme solution and an immiscible oil solution. The oil and hydrogel solutions form emulsions in pressure-driven flow in microchannels at high values of the dimensionless capillary number (Ca). The resultant hydrogel droplets are then polymerized in situ via exposure to 365 nm UV light. This technique allows for the generation of monodisperse particles whose size can be controlled by the regulation of flow rates. In addition, both manufacturing microparticles and immobilizing biocatalysts can be performed simultaneously and continuously.

Biosensing Techniques↗

Synthesis of monodisperse biodegradable microgels in microfluidic devices.

Microgels are promising materials in drug delivery and biomedicine. Although monodisperse microgels would offer considerable advantages, most microgels investigated and used today are polydisperse in size. We report on the fabrication of 10 mum sized monodisperse microgels by emulsifying an aqueous dextran-hydroxyethyl methacrylate (dex-HEMA) phase within an oil phase at the junction of microfluidic channels. Dex-HEMA microgels are biodegradable and are ideally suited for the controlled delivery of proteins.

Biocompatible Materials↗

Surface-directed boundary flow in microfluidic channels.

Channel geometry combined with surface chemistry enables a stable liquid boundary flow to be attained along the surfaces of a 12 microm diameter hydrophilic glass fiber in a closed semi-elliptical channel. Surface free energies and triangular corners formed by PDMS/glass fiber or OTS/glass fiber surfaces are shown to be responsible for the experimentally observed wetting phenomena and formation of liquid boundary layers that are 20-50 microm wide and 12 microm high. Viewing this stream through a 20 microm slit results in a virtual optical window with a 5 pL liquid volume suitable for cell counting and pathogen detection. The geometry that leads to the boundary layer is a closed channel that forms triangular corners where glass fiber and the OTS coated glass slide or PDMS touch. The contact angles and surfaces direct positioning of the fluid next to the fiber. Preferential wetting of corner regions initiates the boundary flow, while the elliptical cross-section of the channel stabilizes the microfluidic flow. The Young-Laplace equation, solved using fluid dynamic simulation software, shows contact angles that exceed 105 degrees will direct the aqueous fluid to a boundary layer next to a hydrophilic fiber with a contact angle of 5 degrees. We believe this is the first time that an explanation has been offered for the case of a boundary layer formation in a closed channel directed by a triangular geometry with two hydrophobic wetting edges adjacent to a hydrophilic surface.

Dimethylpolysiloxanes↗

Microfluidic assembly of homogeneous and Janus colloid-filled hydrogel granules.

The microfluidic assembly of colloid-filled hydrogel granules of varying shape and composition is described. First, drops are formed by shearing a concentrated colloidal microsphere-acrylamide suspension in a continuous oil phase using a sheath-flow device. Both homogeneous and Janus (hemispherically distinct) spheres and disks are produced by confining the assembled drops in microchannels of varying geometry. Next, photopolymerization is carried out shortly after drop breakup to preserve their morphology. Representative wet and dried granules are characterized using fluorescence and scanning electron microscopy, respectively. Our approach offers a facile route for assembling colloid-filled hydrogel granules with controlled shape and composition.

Colloids↗

Screening of C60 crystallization using a microfluidic system.

We have carried out screening of C60 crystallization using a simple liquid/liquid interfacial precipitation method in a microfluidic device. By controlling the time, temperature, and concentration, various metastable phases of C60 crystals were found, including tubes, spheres, open-ended hollow columns, stars, branches, and trees. The obtained C60 crystal shapes are similar to those of snow crystals. These findings suggest an urgent need to screen C60 crystallization for the development of fullerene C60 drugs.

Crystallization↗

Automated formation of lipid-bilayer membranes in a microfluidic device.

Although membrane channel proteins are important to drug discovery and hold great promise as engineered nanopore sensing elements, their widespread application to these areas has been limited by difficulties in fabricating planar lipid-bilayer membranes. We present a method for forming these sub-5-nm-thick free-standing structures based on a self-assembly process driven by solvent extraction in a microfluidic channel. This facile automatable process forms high-quality membranes able to host channel proteins measurable at single-molecule conductance resolution.

Crystallization↗

Microfluidic analysis of antibody specificity in a compact disk format.

A new and flexible technology for high throughput analysis of antibody specificity and affinity is presented. The method is based on microfluidics and takes advantage of compact disks (CDs) in which the centrifugal force moves fluids through microstructures containing immobilized metal affinity chromatography columns. Analyses are performed as a sandwich assay, where antigen is captured to the column via a genetically attached His6-tag. The antibodies to be analyzed are applied onto the columns. Thereafter, fluorescently labeled secondary antibodies recognize the bound primary antibodies, and detection is carried out by laser-induced fluorescence. The CDs contain 104 microstructures enabling analysis of antibodies against more than 100 different proteins using a single CD. Importantly, through the three-dimensional visualization of the binding patterns in a column it is possible to separate high affinity from low affinity binding. The method presented here is shown to be very sensitive, flexible and reproducible.

Animals↗

The proteomic reactor: a microfluidic device for processing minute amounts of protein prior to mass spectrometry analysis.

Gel-free proteomics has emerged as a complement to conventional gel-based proteomics. Gel-free approaches focus on peptide or protein fractionation, but they do not address the efficiency of protein processing. We report the development of a microfluidic proteomic reactor that greatly simplifies the processing of complex proteomic samples by combining multiple proteomic steps. Rapid extraction and enrichment of proteins from complex proteomic samples or directly from cells are readily performed on the reactor. Furthermore, chemical and enzymatic treatments of proteins are performed in 50 nL effective volume, which results in an increased number of generated peptides. The products are compatible with mass spectrometry. We demonstrated that the proteomic reactor is at least 10 times more sensitive than current gel-free methodologies with one protein identified per 440 pg of protein lysate injected on the reactor. Furthermore, as little as 300 cells can be directly introduced on the proteomic reactor and analyzed by mass spectrometry.

Animals↗

Microfluidic ELISA: on-chip fluorescence imaging.

Fluorescent reactions of a heterogeneous sandwich enzyme-linked immunoassay (ELISA) in an all-PDMS [poly (dimethylsiloxane)] microfluidic device were detected using a cooled charge coupled device (CCD) camera interfaced with an epifluorescence microscope. The study represents preliminary efforts to integrate biochemical reactions and detection on-chip using the "hybrid" detection approach. In initial experiments, the PDMS chip microsensor was successfully used to quantify a model analyte (sheep IgM) with sensitivity down to 17nM. Thus, we demonstrate here the extension of this hybrid integrated technique to on-chip imaging and quantification of light emission from a biochemical immunoassay in PDMS chip.

Animals↗

Time-of-flight optophoresis analysis of live whole cells in microfluidic channels.

Optophoresis is a non-invasive cell analysis technique that is based on the interaction of live whole cells with optical gradient fields, typically generated by a near-infrared laser. The magnitude of the interaction depends upon the intrinsic physical properties of the cells, such as their refractive index, composition, size, and morphology. Time-of-flight (TOF) optophoresis is an implementation of this technique in a microfluidic environment. It measures cell travel times through a fixed distance with and without irradiation from a laser beam. The magnitude of the optical force from the laser, and therefore the change in transit time introduced by the presence of the infrared laser provides a signature for the cell. By accumulating such measurements for a population of cells (typically 200-300 cells per population), different cell types, drug treatments, or biological states can be compared quantitatively without the need for external labels or markers. An integrated TOF system has been constructed and characterized. The system typically uses square capillaries with 50-100 microm internal diameter and uses a syringe-pump-based flow system that generates initial bulk flow velocities between 200 and 600 microm/sec. Using this TOF technique, we have been able to consistently detect significant differences between normal skin and melanoma cell lines, CCD-1037 and A375, respectively. We have also been able to measure consistent differences in a cell differentiation model (HL60 cell line with DMSO treatment). These early results indicate the potential biological sensitivity of the TOF measurement technique for cellular analysis and cancer diagnostic applications.

Cell Line, Tumor↗

Centrifugal and electric field forces dual-pumping CD-like microfluidic platform for biomedical separation.

In this article, we propose a versatile CD-like multi-channel electrophoresis-based biomedical separation system that is driven by the interactive forces between the centrifugal force and the electric field force. The centrifugal force control of this system is realized through the velocity control of a DC servo motor, while the electric field is governed through the concentric conducting circuits, which are suitably designed and fabricated by sputtering on metal mask method, and can be adjusted to provide multi-stage voltages. Experimental results demonstrate that the electro-osmotic flow (EOF) effect can be effectively reduced when the electric field force and centrifugal force are in the opposite direction. Benefits from this are that the electrophoresis separation time can be prolonged and the length of the microfluidic channels can be shortened; therefore, more effective separation efficiency can be obtained. Moreover, other advantages, such as lower joule-heat generation, low-chemistry reaction, and no variation on the ion concentration during processes, make this biomedical separation system more useful.

Biopolymers↗

Surface effects on PCR reactions in multichip microfluidic platforms.

We evaluated the compatibility of several common plastics, commercially available plastic tubing and disposable syringes which might be useful in the construction of microfluidic platforms with respect to the polymerase chain reaction (PCR). A simple and inexpensive plastic test module was constructed in order to evaluate some of the construction plastics. We also investigated the effect of addition of PEG 8000 to PCR reaction mixtures on the compatibility of materials. These studies identified several common plastics, plastic tubing, and disposable syringes which were compatible with the PCR reaction.

Equipment Design↗