PubMed Health⌕ Search

PubMed · 16800710

Surface-directed boundary flow in microfluidic channels.

Abstract

Channel geometry combined with surface chemistry enables a stable liquid boundary flow to be attained along the surfaces of a 12 microm diameter hydrophilic glass fiber in a closed semi-elliptical channel. Surface free energies and triangular corners formed by PDMS/glass fiber or OTS/glass fiber surfaces are shown to be responsible for the experimentally observed wetting phenomena and formation of liquid boundary layers that are 20-50 microm wide and 12 microm high. Viewing this stream through a 20 microm slit results in a virtual optical window with a 5 pL liquid volume suitable for cell counting and pathogen detection. The geometry that leads to the boundary layer is a closed channel that forms triangular corners where glass fiber and the OTS coated glass slide or PDMS touch. The contact angles and surfaces direct positioning of the fluid next to the fiber. Preferential wetting of corner regions initiates the boundary flow, while the elliptical cross-section of the channel stabilizes the microfluidic flow. The Young-Laplace equation, solved using fluid dynamic simulation software, shows contact angles that exceed 105 degrees will direct the aqueous fluid to a boundary layer next to a hydrophilic fiber with a contact angle of 5 degrees. We believe this is the first time that an explanation has been offered for the case of a boundary layer formation in a closed channel directed by a triangular geometry with two hydrophobic wetting edges adjacent to a hydrophilic surface.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Tom T Huang, David G Taylor, Kwan Seop Lim, Miroslav Sedlak, Rashid Bashir, Nathan S Mosier, Michael R Ladisch. 2006-07-04. Surface-directed boundary flow in microfluidic channels.. https://doi.org/10.1021/la053465h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Study of on-line monitoring of lactate based on optical fibre sensor and in-channel mixing mechanism.

A PDMS-based microfluidic device with integrated optical fibres was developed for online monitoring of lactate. The detection is based on the optical adsorption of the colour solution formed by in-channel mixing of sample and reagent solutions. Computational Fluid Dynamics (CFD) simulation and kinetic study of the colour development were conducted to determine the minimum channel length and optimum residential time for homogenous mixing and maximum optical adsorption respectively. The system was proved to be able to detect lactate with good linearity (R(2)=0.98), response time of about 130 s and estimated limitation of detection (LOD) of 0.52 mM (about 47 mg/L), which is sufficient for a general online lactate detection. Due to the miniaturization of sensing system and micro-scale mixing, higher detection sensitivity (0.15 V/mM) can be realized than the mixing in lab-scale equipments (0.08 V/mM).

Dimethylpolysiloxanes↗

Glass-fiber reinforced poly(acrylate)-based sorptive materials for the enrichment of organic micropollutants from aqueous samples.

A novel and simple approach to sorptive materials for the extraction of organic compounds from environmental samples is presented. It entails the use of glass fiber fabric strips coated with a customized poly(acrylate) (PA) formulation as extraction medium. Analytes were enriched by means of shaking of the PA strip in the sample and then subsequently thermally desorbed and analyzed by GC-MS. The performance of the sorptive materials was evaluated by the enrichment of compounds with different polarities (phenols, hexachlorobenzene and hexachlorocyclohexanes) from water samples. Parameters that affect the extraction process such as pH, ionic strength of the solvent, mixing mechanism, extraction time and desorption conditions were investigated. The extraction abilities of the PA extraction medium were compared with that of commercially available poly(dimethylsiloxane) (PDMS) Twisters. The results revealed that the new material shows higher affinity for phenolic compounds presumably due to the presence of polar groups. The partition coefficients for the PA strips estimated in this work were up to 15 times higher than for the PDMS Twister, resulting in higher recoveries and lower detection limits. The method was applied for the quantification of the aforementioned compounds in contaminated surface water samples from Bitterfeld (Germany). Using both PA strips and PDMS Twisters, good agreement of the extraction data was achieved.

Dimethylpolysiloxanes↗