Segmenting fluid effect on PCR reactions in microfluidic platforms.

This paper evaluates the compatibility of segmenting fluids for two phase flow applications in biomedical microdevices. The evaluated fluids are chosen due to the variations in fluid properties and cost, while also reflecting their use in the recent literature. These segmenting fluids are examined to determine their compatibility with the Polymerase Chain Reaction (PCR), through controlled experiments. The results are the first to provide a quantitative measure of segmenting fluid compatibility with PCR.

Chemical Fractionation↗

Three dimensional MEMS microfluidic perfusion system for thick brain slice cultures.

In vitro tissue culture models are often benchmarked by their ability to replicate in vivo function. One of the limitations of in vitro systems is the difficulty in preserving an orchestrated cell population, especially for generating three-dimensional tissue equivalents. For example, tissue-engineering applications involve large high-density constructs, requiring a perfusing system that is able to apply adequate oxygen and nutrients to the interior region of the tissue. This is particularly true with respect to thick tissue sections harvested for in vitro culture. We have fabricated a microneedle-based perfusion device for high-cell-density in vitro tissue culture from SU-8 photosensitive epoxy and suitable post-processing. The device was tested for its ability to improve viability in slices of harvested brain tissue. This model was chosen due to its acute sensitivity to disruptions in its nutrient supply. Improved viability was visible in the short term as assessed via live-dead discriminating fluorescent staining and confocal microscopy. This perfusion system opens up many possibilities for both neurobiological as well as other culture systems.

Animals↗

Mixing enhancement of the passive microfluidic mixer with J-shaped baffles in the tee channel.

This study proposed a new design of a passive micromixer employing several J-shaped baffles in the tee channel to enhance mixing. The mixing performance of the device was investigated experimentally and by numerical simulation. The in-plane structured micromixer was fabricated using micromolding of SU-8 photoresist and PDMS. The mixing performance was demonstrated using image analysis to quantify the concentration distribution in the microchannel. The percentage of mixing increased as the number of baffles increased. The simulated and experimental results showed that the mixer with J-shaped baffles exhibited better mixing performance, and the percentage of mixing was about 1.2 to 2.2 times higher when compared to those without baffles, in the range of Reynolds number (Re) 5 to 350. The improvement in mixing performance was especially apparent at the short axial distance and at the lower Reynolds numbers. The results revealed that the J-shaped baffles could result in lateral convection in the main channel, resulting in improved mixing.

Computer Simulation↗

Flexible polyimide probes with microelectrodes and embedded microfluidic channels for simultaneous drug delivery and multi-channel monitoring of bioelectric activity.

The study of intracellular communication requires devices that can not only monitor the bioelectric activity, but also control and observe the biochemical environment at the cellular level. This paper reports on the development and characterisation of implantable polyimide microprobes that allow simultaneous, selective chemical delivery/probing and multi-channel recording/stimulation of bioelectric activity. The key component of the system is a flexible polyimide substrate with embedded microchannels that is batch-fabricated combining polyimide micromachining and a lamination technique. The devices provide platinum microelectrodes on both sides of the polyimide substrate with an active surface between 20 microm x 20 microm and 50 microm x 50 microm. The embedded microchannels permit highly localised drug delivery or probing at the tip of the device via channel outlets adjacent to the microelectrodes. The microelectrodes were characterised by electrical impedance spectroscopy and the microchannels were studied in microflow experiments. Two different fluid delivery schemes were explored in two different designs. The first device type consists of a simple combination of microchannels and microelectrodes on one substrate. Liquids are ejected at the tip of the device by pressure injection techniques. The second device was inspired by the so-called U-tube concept allowing for highly localised delivery of controlled amounts of liquids in the picoliters range. Thus, the influence of chemical compounds on the electrical activity of cells can be studied with high temporal and spatial resolution. The flexible, implantable devices can be used for studying the chemical and electrical information exchange and communication of cells in in vivo and in vitro experiments.

Biosensing Techniques↗

Low-dispersion electrokinetic flows for expanded separation channels in microfluidic systems: multiple faceted interfaces.

A novel methodology to design on-chip conduction channels is presented for expansion of low-dispersion separation channels. Designs are examined using two-dimensional numerical solutions of the Laplace equation with a Monte Carlo technique to model diffusion. The design technique relies on trigonometric relations that apply for ideal electrokinetic flows. Flows are rotated and stretched along the abrupt interface between adjacent regions having differing specific permeability. Multiple interfaces can be placed in series along a channel. The resulting channels can be expanded to extreme widths while minimizing dispersion of injected analyte bands. These channels can provide a long path length for line-of-sight optical absorption measurements. Expanded sections can be reduced to enable point detection at the exit section of the channel. Designed to be shallow, these channels have extreme aspect ratios in the wide section, greatly increasing the surface-to-volume ratio to increase heat removal and decrease unwanted pressure-driven flow. The use of multiple interfaces is demonstrated by considering several three-interface designs. Faceted flow splitters can be constructed to divide channels into any number of exit channels while minimizing dispersion. The resulting manifolds can be used to construct medians for structural support in wide, shallow channels.

Chromatography, Micellar Electrokinetic Capillary↗

Monitoring erythrocytes in a microchip channel that narrows uniformly: towards an improved microfluidic-based mimic of the microcirculation.

The release of adenosine triphosphate (ATP) from red blood cells (RBCs) flowing through PDMS microchannels has been determined as a function of channel cross-sectional area using a design containing a channel that narrows uniformly. ATP, released from the RBCs in response to the mechanical deformation of their cell membranes, increased as the channel cross-section decreased. One sample of rabbit RBCs released 1.16 +/- 0.11, 1.92 +/- 0.14 and 2.09 +/- 0.10 microM ATP as the median cross-sectional area decreased from 4314 to 3192 to 2052 microm(2), respectively. Numerous samples (n = 6) displayed the same trend. Incubating a sample of RBCs with diamide, a substance known to stiffen cell membranes without harming the cell cytosol, provided evidence that no cell lysis occurred in the microchip device. This novel use of lab-on-a-chip technology allows for channel designs that enable an in vitro study of physiological events that occur in the microcirculation.

Adenosine Triphosphate↗

Highly efficient dynamic modification of plastic microfluidic devices using proteins in microchip capillary electrophoresis.

New dynamic coating agents were investigated for the manipulation of electroosmotic flow (EOF) in poly(methylmethacrylate) (PMMA) microchips. Blocking proteins designed for enzyme-linked immunosorbent assay (ELISA) applications (e.g. Block Ace and UltraBlock), and egg-white lysozyme were proposed in this study. The EOF could be enhanced, suppressed or its direction could be reversed, depending on the buffer pH and the charge on the proteins. The coating procedure is simple, requiring only filling of the microchannels with a coating solution, followed by a rinse with a running buffer solution prior to analysis. One major advantage of this method is that it is not necessary to add the coating agent to the running buffer solution. Block Ace and UltraBlock coatings were stable for at least five runs in a given microchannel without the need to condition the coating between runs other than replenishing the buffer solution after each run, i.e. the RSD values of EOF (n=5) were less than 4.3%, and there was no significant change in the EOF after 5 runs. The reproducibility of the coating procedures was found from the channel-to-channel RSD values of the EOF, and were less than 5.0% when using HEPES-Na buffer (pH 7.4) as the running buffer. Several examples of electrophoretic separations of amino acids and biogenic amines derivatized with 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) are demonstrated in this paper. The dynamic coating method has the potential for a broad range of applications in microchip capillary electrophoresis (microchip CE) separations.

Amphetamine↗

Modification of poly(dimethylsiloxane) microfluidic channels with silica nanoparticles based on layer-by-layer assembly technique.

A hydrophilic poly(dimethylsiloxane) (PDMS) microchip with stable electroosmotic flow (EOF) was prepared by a simple and reproducible coating procedure with silica nanoparticles. The microchannel wall of PDMS chip was coated with a layer of poly(diallyldimethylammonium chloride) (PDDA) and then collected silica nanoparticles. The assembly was followed by contact angle, charge-coupled device (CCD) imaging, electroosmotic flow (EOF) measurements and electrophoretic separation experiments. Contact angle measurements revealed the coated surface was hydrophilic; the water contact angle for coated chips was 64 degrees compared with a water contact angle for native PDMS chips of 113 degrees . CCD images indicated a substantially more hydrophilic microchannel than native PDMS. We carried out a comparison and concluded that the EOF values on the coated PDMS chip were close to those values on the glass chip above pH 7.0. The coated channel had an excellent stability and reproducibility, RSD of EOF values (n=6) on native and coated PDMS microchip was 1.58 and 0.57%, respectively. Separation of dopamine and epinephrine was performed on the coated chip generated 1.40 x 10(5), 1.39 x 10(5) theoretical plates/m compared with the native PDMS chip of 0.79 x 10(5), 0.88 x 10(5), high resolution of 1.7 was achieved with a channel of 3.60 cm length.

Dimethylpolysiloxanes↗

Monoliths for microfluidic devices in proteomics.

We report here on the preparation of monolithic capillary columns in view to their integration in a microsystem for on-chip sample preparation before their on-line analysis by electrospray and mass spectrometry (ESI-MS). These monolithic columns are based on polymer materials and consist of reverse phases for peptide separation and/or desalting. They were prepared using lauryl methacrylate (LMA), ethylene dimethacrylate (EDMA) as well as a suitable porogenic mixture composed of cyclohexanol and ethylene glycol. The resulting stationary phases present thus a C12-functionality. The LMA-based columns were first prepared in a capillary format using capillary tubing of 75 microm i.d. and tested in nanoLC-MS experiments for the separation of a commercial Cytochrome C digest composed of 12 peptidic fragments whose isoelectric point values and hydrophobic character cover a wide range. The LMA-based columns were capable of separating the peptidic fragments and their performances were seen to be similar as those of standard commercial columns dedicated to proteomic purposes with calculated separation efficiencies up to 145 x 10(3) plates/m. Monolithic LMA-based phases were then successfully polymerized in microchannels fabricated using the negative photoresist SU-8. After the polymerization, the systems were seen to withstand the pressures applied during the nanoLC-MS separation tests that were carried out in the same conditions as for the monolithic capillary columns. The pressure drop during these tests of the in-microchannel monoliths was as high as 50 bar; however, the separation was not as good as for a capillary format which could be accounted for by the monolith dimensions.

Amino Acid Sequence↗

Fabrication of DNA microarrays onto polymer substrates using UV modification protocols with integration into microfluidic platforms for the sensing of low-abundant DNA point mutations.

We describe the microfabrication and operational characteristics of a simple flow-through biochip sensor capable of detecting low abundant point mutations in K-ras oncogenes from genomic DNA, which carry high diagnostic value for colorectal cancers. The biochip consisted of an allele-specific ligase detection reaction (LDR) coupled to a universal array for interrogating multiple mutations simultaneously from a clinical sample. The integrated sensing platform was micro-manufactured from two different polymers, polycarbonate, PC, which was used for the LDRs, and poly(methyl methacrylate), PMMA, which was used to build the microarray. Passive elements were hot embossed into the PC and PMMA microchips and then, the chips assembled into a three-dimensional architecture with the interconnect fabricated from an elastomer, poly(dimethylsiloxane), PDMS, to produce a leak-free connection between the biochips. The array in PMMA was produced using a photomodification process, which involved three steps; (1) UV (254 nm) exposure of the polymer surface; (2) EDC coupling of amine-terminated oligonucleotide probes to the surface (via an amide bond) and; (3) washing of the surface. The LDR/hybridization flow-through biochip performed the entire assay at a relatively fast processing speed: 6.5 min for on-chip LDR, 10 min for washing, and 2.6 min for fluorescence scanning (total processing time=19.1 min) and could screen multiple mutations simultaneously for high throughput applications at a level of one mutant sequence in 100 wild-type sequences.

Biosensing Techniques↗

Diffusion coefficient measurement in a microfluidic analyzer using dual-beam microscale-refractive index gradient detection. Application to on-chip molecular size determination.

We report a microchip-based detection scheme to determine the diffusion coefficient and molecular mass (to the extent correlated to molecular size) of analytes of interest. The device works by simultaneously measuring the refractive index gradient (RIG) between adjacent laminar flows at two different positions along a microchannel. The device, referred to as a microscale molecular mass sensor (micro-MMS), takes advantage of laminar flow conditions where the mixing of two streams occurs essentially by diffusion across the boundary between the two streams. Two flows merge on the microchip, one containing solvent only, referred to as the mobile phase stream and one which contains the analyte(s) of interest in the solvent, i.e. the sample stream. As these two streams merge and flow parallel to each other down the microchannel a RIG is created by the concentration gradient. The RIG is further influenced by analyte diffusion from the sample stream into the mobile phase stream. Measuring the RIG at a position close to the merging point (upstream signal) and simultaneously a selected distance further down the microchannel (downstream signal) provides real-time data related to the extent a given analyte has diffused, which can be readily correlated to analyte molecular mass by taking the ratio of the downstream-to-upstream signals. For the dual-beam RIG measurements, a diode laser output is coupled to a single mode fiber optic splitter with two output fibers. Light from each fiber passes through a graded refractive index (GRIN) lens forming a collimated beam that then passes through the microchannel and then on to a position sensitive detector (PSD). The RIG at both detection positions deflects the two collimated probe beams. The deflection angle of each beam is then measured on two separate PSDs. The micro-MMS was evaluated using polyethylene glycols (PEGs), sugars, and as a detector for size-exclusion chromatography (SEC). Peak purity can be readily identified using the micro-MMS with SEC. The limit of detection was 0.9 ppm (PEG at 11 840 g/mol) at the upstream detection position corresponding to a RI limit of detection (LOD) (3sigma) of 7-10(-8) RI. The pathlength for the RIG measurement was 200 microm and the angular LOD was 0.23 micro(rad) with a detection volume of 8 nl at both positions. The average molecular mass resolution was 9% (relative standard deviation) for a series of PEGs ranging in molecular mass from 106 to 22 800 g/mol. With this excellent mass resolution, small molecules such as monosaccharides, disaccharides, and so on, are readily distinguished. The sensor is demonstrated to readily determine unknown diffusion coefficients.

Chromatography, Gel↗

Nanoliter-sized liquid dispenser array for multiple biochemical analysis in microfluidic devices.

We have developed a microdispenser array made of PDMS, in which a number of nanoliter-sized droplets can be accurately dispensed and mixed with the aid of specific channels under pneumatic pressure. In this system, hydrophobic and narrow channels act as a kind of valve and help structural liquid manipulation. Also, by arranging multiple dispensers in parallel, a single injection of liquid becomes sufficient for the preparation of multiple nanoliter-sized aliquots for different reactions. We designed two kinds of microdevices for multiple liquid dispensing and mixing and evaluated their performance and reproducibility, proving them sufficient for quantitative reactions. As a practical application, biochemical analysis of glucose was performed using enzymatic reactions. This liquid dispensing technology can be widely applied in the field of microscale analysis due to its low consumption, small dead volume of reagents and samples, and ease of operation.

Equipment Design↗

A glassy carbon microfluidic device for electrospray mass spectrometry.

Due to the broad impact of microfabrication technology on chemistry and biology, new methods to pattern and etch a variety of materials are being explored in a number of laboratories. Here, we report the design, fabrication, and operation of a glassy carbon (GC) microchip interfaced to a nanoelectrospray ionization source and a quadrupole mass spectrometer. The method involves standard photolithographic pattern transfer to a photoresist layer and anodization of the exposed GC substrate in basic electrolyte to produce a series of channels with well-defined wall structure. The performance of the microchip was evaluated with standard polymer and peptide samples.

Carbon↗

Microbioassay system for antiallergic drug screening using suspension cells retaining in a poly(dimethylsiloxane) microfluidic device.

This article describes an antiallergic drug-screening system by the detection of histamine released from mast cells (suspension cells) on a multilayer microchip. In this study, the elastmeric material, poly(dimethylsiloxane) (PDMS), was employed to fabricate microchannels and microchambers. The microchip consists of two sections: a histamine-releasing one, which has a cell chamber, and a histamine-derivatizing one. Both were laminated to one microchip. Rat peritoneal mast cells were retained in the cell chamber (1.2 microL) with a filtering system using a cellulose nitrate membrane. This filtering system could easily retain suspension cells without cell damage. Mast cells were viable for a sufficient time to conduct the assay on the cell chamber. The cells were stimulated with a chemical release compound 48/80 (C48/80), and then histamine flowed into the lower layer, where it was derivatized to the fluorescent molecules with o-phthalaldehyde and its fluorescence was detected on the microchip. This flow system could detect the time course of the histamine release, and this microchip system required only 20 min for the assay. By this integrated system, 51 pmol of histamine released from 500 cells was detected, and the number of cells required for the assay was reduced to 1% compared with conventional bulk systems. By comparing the released histamine levels with and without drugs, their effect could be evaluated. The inhibition ratio of C48/80 induced-histamine release using an antiallergic drug, disodium cromoglicate (DSCG), was related to the concentration of DSCG. This flow system was applicable for antiallergy drug screening by rapid measurement of the inhibition of histamine release from a very small amount of mast cells.

Animals↗

Preconcentration of proteins on microfluidic devices using porous silica membranes.

Fluorescently labeled proteins were electrophoretically concentrated on microfabricated devices prior to separation and laser-induced fluorescence detection on the same device. The proteins were concentrated using a porous silica membrane between adjacent microchannels that allowed the passage of buffer ions but excluded larger migrating molecules. Concentrated analytes were then injected into the separation column for analysis. Two basic microchip designs were tested that allowed sample concentration either directly in the sample injector loop or within the microchannel leading from the sample reservoir to the injector. Signal enhancements of approximately 600-fold were achieved by on-chip preconcentration followed by SDS-CGE separation. Preconcentration for CE analysis in both coated and uncoated open channels was also demonstrated. Fluorescently labeled ovalbumin could be detected at initial concentrations as low as 100 fM by using a combination of field-amplified injection and preconcentration at a membrane prior to CE in coated channels.

Electrophoresis, Capillary↗

Cationic starch derivatives as dynamic coating additives for analysis of amino acids and peptides using poly(methyl methacrylate) microfluidic devices.

Plastic microchips are very promising analytical devices because they are less fragile and are suitable for mass production. However, due to their hydrophobicity, the surface strongly interacts with nonpolar analytes or species containing hydrophobic domains, resulting in significant uncontrolled adsorption on channel walls. This paper describes the poly(methyl methacrylate) surface treatment by dynamic coating additives that considerably decreases adsorption of analytes to channel walls. Among the additives studied, quaternary ammonium starch derivatives suppressed the adsorption of fluorescently labeled amino acids and peptides most effectively. The effect was valid over the wide pH range from 2.5 to 8.0. Using a 10 mM phosphate buffer (pH 7.0) with 3% (w/v) quaternary ammonium starch as the running buffer, Asp and Glu, respectively, migrated at 54.6 and 57.6 s with efficiencies of 380 000 and 370 000 plates/m. In addition, this cationic starch derivative was found to possess good solubility and low viscosity.

Amino Acids↗

Electrowetting-based microfluidics for analysis of peptides and proteins by matrix-assisted laser desorption/ionization mass spectrometry.

A new technique for preparing samples for matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) is reported. The technique relies on electrowetting-on-dielectric (EWOD) to move droplets containing proteins or peptides and matrix to specific locations on an array of electrodes for analysis. Standard MALDI-MS reagents, analytes, concentrations, and recipes are demonstrated to be compatible with the technique. Mass spectra are comparable to those collected by conventional methods. Nonspecific adsorption of analytes to device surfaces is demonstrated to be negligible. The results suggest that EWOD may be a useful tool for automating sample preparation for high-throughput proteomics and other applications of MALDI-MS.

Equipment Design↗

Contamination-free continuous flow microfluidic polymerase chain reaction for quantitative and clinical applications.

We present a method for performing polymerase chain reaction (PCR) using isolated droplets flowing in an immiscible fluorinated solvent system. Thanks to an optimized control of interfacial properties, we could achieve in this capillary-based system reproducible amplification factors, without any detectable contamination between neighboring droplets. The system is readily amenable to further miniaturization and automation and serves as the first step toward a clinically viable, high-throughput, quantitative continuous flow PCR apparatus.

DNA↗