PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 163 records · Page 9Linked to original sources

Assay development and high-throughput screening of caspases in microfluidic format.

Caspase proteases are familiar targets in drug discovery. A common format for screening to identify caspase inhibitors employs fluorogenic or colorimetric tetra-peptide substrates in 96, 384, or 1536 -well microtiter plates. The primary motivation for increasing the number of wells per plate is to reduce the reagent cost per test and increase the throughput of HTS operations. There are significant challenges, however, to moving into or beyond the 1536-well format, such as submicroliter liquid handling, liquid evaporation, increased surface area-to-volume ratios, and the potential for artifacts and interference from small air-borne particles such as lint. Therefore, HTS scientists remain keenly interested in technologies that offer alternatives to the ever-shrinking microtiter plate well. Microfluidic assay technology represents an attractive option that, in theory, consumes only subnanoliter volumes of reagents per test. We have successfully employed a microfluidic assay technology in fluorogenic screening assays for several caspase isoforms utilizing the Caliper Technologies Labchip platform. Caspase-3 is used as a representative case to describe microfluidic assay development and initial high-throughput screening results. In addition, microfluidic screening and plate-based screening are compared in terms of reagent consumption, data quality, and ease of operation.

Caspase Inhibitors↗

Recent advances in the large-scale production of lipid vesicles for use in food products: microfluidization.

The development of a method for the continuous mass production of liposomes is vital for the industrial use of liposomes in food products. The method should be mild enough to prevent denaturation of the encapsulated material, and the materials used for the preparation of the liposomes should be safe and edible. Among the methods available, microfluidization seems to be the most promising. Microfluidization consists of processing emulsions under high pressure through an apparatus called a Microfluidizer. This apparatus also allows the production of another type of lipid vesicle: milkfat-coated microcapsules composed of milkfat and emulsifiers. The main advantages of microfluidization include the continuous production of large quantities of lipid vesicles without dissolving the phospholipids in organic solvents. These vesicles could be used in various food products for a variety of objectives. The addition of encapsulated material in liposomes or in milkfat-coated microcapsules to cheese milk resulted in a retention of 80-90% of the vesicles in the cheese, compared to only 2-4% if the material was added directly to the milk in the unencapsulated form. Liposomes and milkfat-coated microcapsules could be used as enzyme carriers to accelerate cheese ripening, or as carriers for flavouring systems to improve the organoleptic properties of low-fat cheeses or to impart distinctive flavours to new speciality cheeses. These microcapsules could also be used in food products to avoid undesirable side-reactions during food processing, or to supplement food products with nutritious additives.

Animals↗

High-throughput and real-time study of single cell electroporation using microfluidics: effects of medium osmolarity.

Electroporation has been widely accepted as an important tool for the delivery of exogenous molecules into cells. Previous mechanistic studies have been carried out by observing either the average behavior from a large population of cells or the response from a small number of single cells. In this study, we demonstrated a novel microfluidic method with high throughput (up to 30 Hz) for real-time studies of single cell electroporation events. Electroporation occurred when cells flowed through a section of a microfluidic channel defined by special geometry. A CCD camera was used to monitor the response of cells starting from the onset of the electroporation. We studied the swelling of Chinese hamster ovary cells and the rupture of cell membrane during electroporation using this technique. We applied buffers with different osmolarities to investigate the effects of medium osmolarity, based on results from a population of single cells. We were able to establish the distributions of the rates of swelling and membrane rupture in the cell population. We also explored establishing the correlation between the property (the cell diameter) and the behavior (the swelling rate) of single cells. Our results indicated that the processes of swelling and rupture occurred more rapidly in the hypotonic or hypertonic buffers than in the isotonic buffer. Statistical analysis did not reveal strong linear correlation between the cell size and the swelling rate. These proof-of-concept studies reveal the potential of applying microfluidics to study electroporation of a cell population at single cell level in real time with high throughput. The limitations associated with this approach were also addressed.

Animals↗

Gravity-induced convective flow in microfluidic systems: electrochemical characterization and application to enzyme-linked immunosorbent assay tests.

A way of using gravity flow to induce a linear convection within a microfluidic system is presented. It is shown and mathematically supported that tilting a 1 cm long covered microchannel is enough to generate flow rates up to 1000 nL.min(-1), which represents a linear velocity of 2.4 mm.s(-1). This paper also presents a method to monitor the microfluidic events occurring in a covered microchannel when a difference of pressure is applied to force a solution to flow in said covered microchannel, thanks to electrodes inserted in the microfluidic device. Gravity-induced flow monitored electrochemically is applied to the performance of a parallel-microchannel enzyme-linked immunosorbent assay (ELISA) of the thyroid-stimulating hormone (TSH) with electrochemical detection. A simple method for generating and monitoring fluid flows is described, which can, for instance, be used for controlling parallel assays in microsystems.

Electricity↗

Microfluidics to Follow Spatiotemporal Dynamics at the Nucleo-Cytoplasmic Interface During Plant Root Growth.

Nuclear dynamics refers to global/local changes in the molecular and spatial organization of genomic DNA that can occur during development or in response to environmental stress signals and eventually impact genomic functions. In plants, nuclear dynamics relies notably on the connection of the nucleus with the cytoskeleton during development. It orchestrates genomic functions in response to developmental and environmental cues. This is particularly true in the plant root system, which is constantly exposed to a wide range of internal and external stimuli. Currently, studying nuclear dynamics in a growing root is challenging due to limitations regarding real-time imaging for quantitative analyses under controlled conditions. Microfluidic systems for plant cell studies are valuable analytical tools that provide precise control of culture conditions together with live-imaging capabilities at high temporal and spatial resolutions. Herein, we describe a microfluidic platform to unravel dynamically and noninvasively nuclear organization in the seedling root system exposed to various treatments. As exemplified here, our microfluidic platform can be conveniently used for real-time microscopy imaging and quantitative analysis of fine nuclear morphological changes upon modifying cytoskeleton dynamics. Importantly, our system can be applied to a wide variety of microscopic means including high-resolution microscopy to investigate diverse subcellular compartments or nuclear domains in Arabidopsis thaliana roots.

Plant Roots↗

Fabrication of cell-containing hydrogel microstructures inside microfluidic devices that can be used as cell-based biosensors.

This paper describes microfluidic systems containing immobilized hydrogel-encapsulated mammalian cells that can be used as cell-based biosensors. Mammalian cells were encapsulated in three-dimensional poly(ethylene glycol)(PEG) hydrogel microstructures which were photolithographically polymerized in microfluidic devices and grown under static culture conditions. The encapsulated cells remained viable for a week and were able to carry out enzymatic reactions inside the microfluidic devices. Cytotoxicity assays proved that small molecular weight toxins such as sodium azide could easily diffuse into the hydrogel microstructures and kill the encapsulated cells, which resulted in decreased viability. Furthermore, heterogeneous hydrogel microstructures encapsulating two different phenotypes in discrete spatial locations were also successfully fabricated inside microchannels.

3T3 Cells↗

Combined microfluidic-micromagnetic separation of living cells in continuous flow.

This paper describes a miniaturized, integrated, microfluidic device that can pull molecules and living cells bound to magnetic particles from one laminar flow path to another by applying a local magnetic field gradient, and thus selectively remove them from flowing biological fluids without any wash steps. To accomplish this, a microfabricated high-gradient magnetic field concentrator (HGMC) was integrated at one side of a microfluidic channel with two inlets and outlets. When magnetic micro- or nano-particles were introduced into one flow path, they remained limited to that flow stream. In contrast, when the HGMC was magnetized, the magnetic beads were efficiently pulled from the initial flow path into the collection stream, thereby cleansing the original fluid. Using this microdevice, living E. coli bacteria bound to magnetic nanoparticles were efficiently removed from flowing solutions containing densities of red blood cells similar to that found in blood. Because this microdevice allows large numbers of beads and cells to be sorted simultaneously, has no capacity limit, and does not lose separation efficiency as particles are removed, it may be especially useful for separations from blood or other clinical samples. This on-chip HGMC-microfluidic separator technology may potentially allow cell separations to be carried out in the field outside of hospitals and clinical laboratories.

Cell Separation↗

Arrays of horizontally-oriented mini-reservoirs generate steady microfluidic flows for continuous perfusion cell culture and gradient generation.

This paper describes the use of arrays of horizontally-oriented reservoirs to deliver liquids through microchannels at a constant flow rate over extended periods of time (hours to days). The horizontal orientation maintains a constant hydraulic pressure drop across microfluidic channels even as the volumes of liquids within the reservoirs change over time. For a given channel-reservoir system, the magnitude of the flow velocity depends linearly on the height difference between reservoirs. The simple structure and operation mechanism make this pumping system versatile. A one-inlet-one-outlet system was used to continuously deliver media for perfusion cell culture, and an array of inlet reservoirs coupled to an outlet reservoir via microchannels was used to drive flows of multiple laminar streams. The parallel pumping scheme conveniently generated various smooth and step concentration gradients, and allowed evaluation of the effect of colchicine on myoblasts. Since the reservoir arrays are configured to be compatible with commercialized multichannel pipettors designed for 96 well plate handling, this simple pumping scheme is envisioned to be broadly useful for medium to high throughput microfluidic perfusion cell culture assays, cell migration assays, multiple laminar flow drug tests, and any other applications needing multiple microfluidic streams.

Cell Culture Techniques↗

Microfluidic operations using deformable polymer membranes fabricated by single layer soft lithography.

We show that it is possible to use single layer soft lithography to create deformable polymer membranes within microfluidic chips for performing a variety of microfluidic operations. Single layer microfluidic chips were designed, fabricated, and characterized to demonstrate pumping, sorting, and mixing. Flow rates as high as 0.39 microl min(-1) were obtained by peristaltic pumping using pneumatically-actuated membrane devices. Sorting was attained via pneumatic actuation of membrane units placed alongside the branch channels. An active mixer was also demonstrated using single-layer deformable membrane units.

Equipment Design↗

Microfluidic system for dielectrophoretic separation based on a trapezoidal electrode array.

This paper presents a novel microfluidic device for dielectrophoretic separation based on a trapezoidal electrode array (TEA). In this method, particles with different dielectric properties are separated by the device composed of the TEA for the dielectrophoretic deflection of particles under negative dielectrophoresis (DEP) and poly(dimethylsiloxane)(PDMS) microfluidic channel with a sinuous and expanded region. Polystyrene microparticles are exposed to an electric field generated from the TEA in the microfluidic channel and are dielectrophoretically focused to make all of them line up to one sidewall. When these particles arrive at the region of another TEA for dielectrophoretic separation, they are separated having different positions along the perpendicular direction to the fluid flow due to their different dielectrophoretic velocities. To evaluate the separation process and performance, both the effect of the flow rate on dielectrophoretic focusing and the influence of the number of trapezoidal electrodes on dielectrophoretic separation are investigated. Now that this method utilizes the TEA as a source of negative DEP, non-specific particle adhering to the electrode surface can be prevented; conventional separation approaches depending on the positive DEP force suffer from this problem. In addition, since various particle types are continuously separated, this method can be easily applicable to the separation and analysis of various dielectric particles with high particle recovery and selectivity.

Dimethylpolysiloxanes↗

Development of an integrated microfluidic platform for dynamic oxygen sensing and delivery in a flowing medium.

This paper describes a platform for real-time sensing of dissolved oxygen in a flowing microfluidic environment using an oxygen-sensitive luminescent dye (platinum octaethylporphyrin ketone) integrated into a micro-oxygenator device. Using a phase-based detection method, the luminescent decay lifetime of the dye was consistent with the linear Stern-Volmer relationship using both gaseous and aqueous samples. Maximum sensor resolution varied between 120-780 ppb across a range of dissolved oxygen (DO) concentrations ranging from 0-42.5 ppm. The sensor was subsequently used to determine the convective mass-transfer characteristics of a multi-layer polydimethylsiloxane (PDMS) microfluidic oxygenator. The membrane-based oxygenator showed excellent agreement with an analytical convection model, and the integrated oxygen sensor was accurate across a wide range of tested flow rates (0.05-5 mL min(-1)). The device is unique for its ease of fabrication and highly flexible configuration, as well as the novel incorporation of oxygen delivery and detection in a single micro-device. Potential applications include tissue engineering, cell culturing, and miniaturized bio-assays that require the delivery and/or detection of precise quantities of oxygen within a microfluidic construct.

Biological Assay↗

Electrokinetic concentration enrichment within a microfluidic device using a hydrogel microplug.

A simple and efficient approach for concentration of charged molecules in microfluidic devices is described. The functional component of the system is a hydrogel microplug photopolymerized within the main channel of a microfluidic device. When an appropriately biased voltage is applied across the hydrogel, charged analyte molecules move from the source well toward the hydrogel. Transport of the analyte through the hydrogel is slow compared to its velocity in the microfluidic channel, however, and therefore it concentrates at the hydrogel/solution interface. For an uncharged hydrogel, a bias of 100 V leads to a approximately 500-fold enrichment of the DNA concentration within 150 s, while the same conditions result in an enrichment of only 50-fold for fluorescein. Somewhat lower enrichment factors are observed when a negatively charged hydrogel is used. A qualitative model is proposed to account for the observed behavior.

Anions↗

A three-channel microfluidic device for generating static linear gradients and its application to the quantitative analysis of bacterial chemotaxis.

We have developed a prototype three-channel microfluidic chip that is capable of generating a linear concentration gradient within a microfluidic channel and is useful in the study of bacterial chemotaxis. The linear chemical gradient is established by diffusing a chemical through a porous membrane located in the side wall of the channel and can be established without through-flow in the channel where cells reside. As a result, movement of the cells in the center channel is caused solely by the cells chemotactic response and not by variations in fluid flow. The advantages of this microfluidic chemical linear gradient generator are (i) its ability to produce a static chemical gradient, (ii) its rapid implementation, and (iii) its potential for highly parallel sample processing. Using this device, wildtype Escherichia coli strain RP437 was observed to move towards an attractant (e.g., l-asparate) and away from a repellent (e.g., glycerol) while derivatives of RP437 that were incapable of motility or chemotaxis showed no bias of the bacteria's distribution. Additionally, the degree of chemotaxis could be easily quantified using this assay in conjunction with fluorescence imaging techniques, allowing for estimation of the chemotactic partition coefficient (CPC) and the chemotactic migration coefficient (CMC). Finally, using this approach we demonstrate that E. coli deficient in autoinducer-2-mediated quorum sensing respond to the chemoattractant l-aspartate in a manner that is indistinguishable from wildtype cells suggesting that chemotaxis is insulated from this mode of cell-cell communication.

Cell Communication↗

Biomimetic design of microfluidic manifolds based on a generalised Murray's law.

The relationship governing the optimum ratio between the diameters of the parent and daughter branches in vascular systems was first discovered by Murray using the principle of minimum work. This relationship is now known as Murray's law and states that the cube of the diameter of the parent vessel must equal the sum of the cubes of the daughter vessels. For symmetric bifurcations, an important consequence of this geometric rule is that the tangential shear stress at the wall remains constant throughout the vascular network. In the present paper, we extend this important hydrodynamic concept to arbitrary cross-sections and provide a framework for constructing a simple but elegant biomimetic design rule for hierarchical microfluidic networks. The paper focuses specifically on constant-depth rectangular and trapezoidal channels often employed in lab-on-a-chip systems. To validate our biomimetic design rule and demonstrate the application of Murray's law to microfluidic manifolds, a comprehensive series of computational fluid dynamics simulations have been performed. The numerical predictions are shown to be in very good agreement with the theoretical analysis, confirming that the generalised version of Murray's law can be successfully applied to the design of constant-depth microfluidic devices.

Biomimetics↗

Microfluidic gas-flow profiling using remote-detection NMR.

We have used nuclear magnetic resonance (NMR) to obtain spatially and temporally resolved profiles of gas flow in microfluidic devices. Remote detection of the NMR signal both overcomes the sensitivity limitation of NMR and enables time-of-flight measurement in addition to spatially resolved imaging. Thus, detailed insight is gained into the effects of flow, diffusion, and mixing in specific geometries. The ability for noninvasive measurement of microfluidic flow, without the introduction of foreign tracer particles, is unique to this approach and is important for the design and operation of microfluidic devices. Although here we demonstrate an application to gas flow, extension to liquids, which have higher density, is implicit.

Diffusion↗

The analytical approach to polydimethylsiloxane microfluidic technology and its biological applications.

This review article discusses PDMS (polydimethylsiloxane) microfluidic devices and their biological applications. First, the already developed devices are classified from the viewpoints of underlying technology within a common logical framework comprising single-layer, multilayer, and integrated devices, as well as surface chemistry modifications of PDMS. Combinatorial techniques are applied to re-derive existing devices within this framework. Next, the relevant scales of both microfluidics and biology are compared, obtaining the promise and limitations of PDMS microfluidics. Finally, the body of work is reclassified in terms of addressed biological applications and compared to the standard methods in cellular and molecular biology, to offer insights for future devices and applications.

Animals↗

[Application of microfluidic-chip in biomedicine].

As a novel analytical technology, the research of Micro total analysis systems (micro-TAS) has been spreading rapidly. micro-TAS has been widely used to perform chemical and biochemical analysis. Microfluidic-based analytical system as micro-TAS's manily direction develops very fast in terms of it's reaction speed, reagent consumption, miniaturization, cost, and automation. After having proven the value of microfluidics for genetic, proteomic and cytomics analysis, this article also anticipates the development tendency of this technology in the biology medicine domain. It has demonstrated that a truly, easy-to-handle Microfluidic-based analytical device will be emerged in the future.

Humans↗

Reactions in droplets in microfluidic channels.

Fundamental and applied research in chemistry and biology benefits from opportunities provided by droplet-based microfluidic systems. These systems enable the miniaturization of reactions by compartmentalizing reactions in droplets of femoliter to microliter volumes. Compartmentalization in droplets provides rapid mixing of reagents, control of the timing of reactions on timescales from milliseconds to months, control of interfacial properties, and the ability to synthesize and transport solid reagents and products. Droplet-based microfluidics can help to enhance and accelerate chemical and biochemical screening, protein crystallization, enzymatic kinetics, and assays. Moreover, the control provided by droplets in microfluidic devices can lead to new scientific methods and insights.

Microfluidic Analytical Techniques↗