PubMed Health⌕ Search

Biomedical subjects

Darko Stefanovic

Publications and source records attributed to Darko Stefanovic.

9 recordsLinked to original sources

A rational approach to minimal high-resolution cross-reactive arrays.

We report a rational approach to the construction of cross-reactive arrays for steroids consisting of five to seven sensors incorporating modified oligonucleotides. The sensors for our arrays were selected to maximize their differential responses to the two steroids most different in an arbitrarily chosen parameter named "shape-length". The arrays incorporated three previously unreported types of sensors identified through a massive screening effort: (1) three-way junction sensors with neutralized charges within junction; (2) "self-aggregating sensors"; and (3) sensors incorporating fluorophore directly in a three-way junction as a spacer. The arrays were tested on seven steroids and an alkaloid (cocaine) over a range of concentrations, and achieved 92-96% accuracy in class assignments, despite the close structural similarities between steroids.

Biosensing Techniques↗

Behavior of polycatalytic assemblies in a substrate-displaying matrix.

We describe polycatalytic assemblies, comprising one or two streptavidin molecules and two to six attached nucleic acid catalysts (deoxyribozymes), with phosphodiesterase activity. When exposed to a matrix covered at high densities with oligonucleotide substrates, these molecules diffuse through the matrix continuously cleaving the substrate at rates comparable to those of individual catalysts in solution. Rates of diffusion (movement), processivity, and resident times of assemblies can be controlled through the number of catalytic units and the length of substrate/product recognition regions. The assemblies were characterized at the ensemble level using surface plasmon resonance.

Catalysis↗

Characterization of transverse channel concentration profiles obtainable with a class of microfluidic networks.

We analyze mathematically a previously reported class of passive microfluidic mixing networks. The networks produce nonhomogeneous concentrations in the output channel, resulting in diverse concentration profiles. We formally prove that all profiles obtainable with this class of networks can be described as polynomials of degree no higher than the number of input channels less one. We derive explicit formulas for the calculation of resultant output concentration profiles and conversely for the calculation of input concentrations needed to obtain set output profiles.

Journal Article↗

Deoxyribozyme-based three-input logic gates and construction of a molecular full adder.

We have developed an array of seven deoxyribozyme-based molecular logic gates that behaves as a full adder in a single solution, with three oligonucleotides as inputs and two independent fluorogenic cleavage reactions as carry and sum outputs. The sum output consisted of four new deoxyribozyme-based logic gates: an ANDAND gate and three ANDNOTANDNOT gates. These gates required the design of a generic three-input deoxyribozyme-based logic gate that can use any three-way combination of activating or inactivating inputs. This generic gate design utilizes an additional inverting element that hybridizes to convert YES logic into NOT logic and vice versa. The system represents the first solution-phase, single test tube, enzymatic full adder and shows the complexity of control over molecular scale events that can be achieved with deoxyribozyme-based logic gates. Similar systems could be applied to control autonomous therapeutic and diagnostic devices.

Base Sequence↗

Medium scale integration of molecular logic gates in an automaton.

The assembly of molecular automata that perform increasingly complex tasks, such as game playing, presents an unbiased test of molecular computation. We now report a second-generation deoxyribozyme-based automaton, MAYA-II, which plays a complete game of tic-tac-toe according to a perfect strategy. In silicon terminology, MAYA-II represents the first "medium-scale integrated molecular circuit", integrating 128 deoxyribozyme-based logic gates, 32 input DNA molecules, and 8 two-channel fluorescent outputs across 8 wells.

Algorithms↗

Solution-phase molecular-scale computation with deoxyribozyme-based logic gates and fluorescent readouts.

Recent development of solution-phase molecular-scale Boolean calculations using deoxyribozymes is potentially an important step toward the development of autonomous therapeutic and diagnostic devices. Here, the construction of basic YES, AND, ANDNOT, and ANDANDNOT deoxyribozyme-based logic gates is described. Protocols for testing gate activity using fluorescent oligonucleotide probes have been provided, and pointers for gate optimization are included.

Base Sequence↗

Deoxyribozyme-based ligase logic gates and their initial circuits.

A complete set (YES, NOT, AND, and ANDNOT) of molecular scale logic gates based on ligase deoxyribozymes was constructed. The activity of these gates was visualized through the formation of cascades with downstream phosphodieseterase YES gates, which performed fluorogenic cleavage.

Base Sequence↗

A deoxyribozyme-based molecular automaton.

We describe a molecular automaton, called MAYA, which encodes a version of the game of tic-tac-toe and interactively competes against a human opponent. The automaton is a Boolean network of deoxyribozymes that incorporates 23 molecular-scale logic gates and one constitutively active deoxyribozyme arrayed in nine wells (3x3) corresponding to the game board. To make a move, MAYA carries out an analysis of the input oligonucleotide keyed to a particular move by the human opponent and indicates a move by fluorescence signaling in a response well. The cycle of human player input and automaton response continues until there is a draw or a victory for the automaton. The automaton cannot be defeated because it implements a perfect strategy.

Algorithms↗

Deoxyribozyme-based logic gates.

We report herein a set of deoxyribozyme-based logic gates capable of generating any Boolean function. We construct basic NOT and AND gates, followed by the more complex XOR gate. These gates were constructed through a modular design that combines molecular beacon stem-loops with hammerhead-type deoxyribozymes. Importantly, as the gates have oligonucleotides as both inputs and output, they open the possibility of communication between various computation elements in solution. The operation of these gates is conveniently connected to a fluorescent readout.

Base Sequence↗