PubMed Health⌕ Search

PubMed · 11191177

Retention.

Abstract

This article describes the mechanisms for retaining RPDs and considers the different types of direct retainer. The factors influencing the effectiveness of retentive clasps and governing the choice of clasp are discussed.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J C Davenport, R M Basker, J R Heath, J P Ralph, P O Glantz. 2000-12-23. Retention.. https://doi.org/10.1038/sj.bdj.4800854

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prosthetic parts.

Explore the source record for details and available documents.

Dental Clasps↗

Clasp design.

Explore the source record for details and available documents.

Dental Clasps↗

Retention of maxillary implant overdenture bars of different designs.

STATEMENT OF PROBLEM: The specific degree of retention for overdenture attachments is unknown in relation to design, location, and alignment to supporting dental implants. PURPOSE: The purpose of this study was to evaluate the initial retention characteristics of 5 implant maxillary overdenture designs under in vitro dislodging forces. MATERIAL AND METHODS: A simulated edentulous maxilla was fabricated with 4 screw-type 3.75 x 13-mm implants anteriorly. Five overdenture designs with the following attachments were evaluated: 4 plastic Hader clips with an EDS bar; 2 plastic anterior Hader clips with an identical EDS bar; 2 Hader clips with 2 posterior ERA attachments; 3 Zaag attachments on a bar; and 4 Zaag attachments with no bar. Overdentures were fabricated with full palatal coverage. Each design was subjected to 10 consecutive retention pulls on a universal testing machine. Data were subjected to analysis of variance and t tests to determine differences. RESULTS: The highest average value after 10 pulls was 19.8 lb for the combination ERA and Hader clip design. The lowest retentive values were recorded for the 2 and 4 Hader clip designs (5.08 +/- 0.89 lb and 5.06 +/- 0.67 lb, respectively). Retention decreased over the course of consecutive pulls for all designs, especially for the most retentive designs. The smallest retention decrease occurred with the least retentive designs. CONCLUSION: The results of this in vitro study suggest that the precise selection and placement of attachments may affect the clinical success of maxillary implant-retained overdentures.

Dental Clasps↗