[Individually CAD-CAM technique designed, bioresorbable 3-dimensional polycaprolactone framework for experimental reconstruction of craniofacial defects in the pig].

Abstract

METHODS: Twenty orbital defects (2 x 2 cm) were created in ten adult Yorkshire pigs. Two software products (Velocity and Mimix) were evaluated with regard to image processing, three-dimensional reconstruction, and fabrication of individually shaped polycaprolactone (PCL) scaffolds to reconstruct these defects. Four different techniques were tested for the reconstruction: group 1 = no reconstruction, group 2 = polylactide sheet, group 3 = PCL scaffold, group 4 = bone marrow-coated PCL scaffold. The pigs were sacrificed at 3 months. RESULTS: In group 1 soft tissue scar formation could be found, but without any new bone. Group 2 showed a thick fibrous capsule around the PLLA sheet, whereas at the border zone of the defect signs of new bone formation could be detected. In group 3 the PCL scaffolds were filled with fibrous tissue and some areas that showed new bone formation (6.4% of the area of the defect). In group 4 the new bone formation (17.8% of the area of the defect) was significantly higher in quantity than in group 3. CONCLUSION: The PCL scaffold coated with bone marrow seems to be a material that effectively provides osteoinduction with formation of new bone. Long-term results at 12 months are still pending.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

D Rohner, D W Hutmacher, P See, K C Tan, V Yeow, S Y Tan, S T Lee, B Hammer. 2002. [Individually CAD-CAM technique designed, bioresorbable 3-dimensional polycaprolactone framework for experimental reconstruction of craniofacial defects in the pig].. https://doi.org/10.1007/s10006-002-0389-0

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Long-term study of high-strength hydroxyapatite/poly(L-lactide) composite rods for the internal fixation of bone fractures: a 2-4-year follow-up study in rabbits.

Biodegradation of hydroxyapatite (HA)/poly(L-lactide)(PLLA) composite bone implant rods was studied with the use of two types of HA particles as reinforcing fillers: uncalcined HA (u-HA) or calcined HA (c-HA). Composite rods of u-HA/PLLA and c-HA/PLLA containing 30 or 40% (w/w) HA were implanted in the distal femur of 21 rabbits, and specimens were examined by light microscopy, scanning-electron microscopy (SEM), and transmission-electron microscopy (TEM) 2-4 years later. For u-HA/PLLA, trabecular bone bonding directly onto the rod was maintained for up to 2 years. By 3 years, surface collapse had begun, and the implants were shrinking. By 4 years, they had shrunk further, with complete bone encapsulation. The u-HA particles were small and needle shaped in the peripheries, and TEM confirmed their resorption. The cross-sectional area after 4 years decreased by 23.3+/-8.4%. The mean ratio of bony ingrowth to the initial cross-sectional area around the shrunken rods was 6.7+/-1.3 %. The viscosity molecular weight of PLLA reduced from 2 x 10(5) to less than 1 x 10(3). Thus, most of the PLLA had released from the rods. The c-HA/PLLA implants also showed good osteoconductivity, but shrinkage and infiltration of histiocytes were less. No osteolytic or osteoarthritic changes were found.

Absorbable Implants↗

In vivo efficacy of bone-marrow-coated polycaprolactone scaffolds for the reconstruction of orbital defects in the pig.

Alloplastic materials offer a number of advantages over bone autografts in the reconstruction of craniofacial defects. These include: lack of donor site morbidity, unlimited quantities of available material, and the possibility to conform exactly to the defect. An ideal bioresorbable material would degrade slowly, and have osteoconductive properties to allow replacement and remodeling by osseous tissue. This is seldom observed, the materials instead being replaced by fibrous tissue. Polycaprolactone (PCL), an FDA-approved bioresorbable polymer, has several properties that might make it suitable for reconstruction of craniofacial defects. The technique of fused deposition modeling (FDM) allows for the fabrication of highly reproducible bioresorbable 3D scaffolds. The nature of the fully interconnected pore network might enhance vascular ingrowth and osteoconductive properties. It was hypothesized that coating the scaffolds in bone marrow might enhance bone formation due to the osteoinductive nature of the bone-marrow mesenchymal cells. This study aimed to test these hypotheses in the pig model. Defects measuring 2 x 2 cm were surgically created in each orbit of eight Yorkshire pigs. The orbits were divided into three groups: Group 1 (n=4), no reconstruction (control); Group 2 (n=6), reconstruction with no coated PCL scaffolds; and Group 3 (n=6) reconstruction with bone-marrow-coated PCL scaffolds. The results were evaluated at 3 months by histological and histomorphometric analyses. The defects in Group 1 were covered with fibrous scar tissue. The shape of the reconstructed area was insufficient. The defects in Groups 2 and 3 were reconstructed correctly. In Group 2 the noncoated scaffolds showed 4.5% of new bone formation compared with 14.1% in Group 3, which is statistically significant (p<0.05). The entirely interconnected 3D polycaprolactone scaffold seems to be a promising material. It induces the bone ingrowth required for reconstructing craniofacial and orbital defects. Further long-term evaluations of these PCL scaffolds must be made in order to confirm these conclusions.

Absorbable Implants↗

Matrix and bioabsorbable polymeric coils accelerate healing of intracranial aneurysms: long-term experimental study.

BACKGROUND AND PURPOSE: Acceleration of intra-aneurysmal clot organization and fibrosis may be a solution to preventing aneurysm recanalization after endovascular treatment. The purpose of this study was to evaluate the short-term efficacy and long-term safety of the new Matrix coil system. METHODS: Matrix coils consist of thin platinum coils covered with a bioabsorbable, polymeric material (polyglycolic acid/lactide). Fifty-two experimental aneurysms were created in 26 swine. All of the aneurysms were tightly packed with Matrix or Guglielmi detachable coils (GDC). Comparative angiographic and histopathologic data were analyzed at 2 weeks (n=14), 3 months (n=6), and 6 months (n=6) after embolization. RESULTS: Three aneurysms treated with GDC ruptured despite tight packing. No recanalization or rupturing was observed in the aneurysms embolized with Matrix coils. At 14 days after embolization, the aneurysms treated with Matrix coils exhibited a more extensive area of organized thrombus when compared with the aneurysms treated with GDC (87% versus 75%, P=0.008, n=11). At 3 months, both Matrix and GDC-treated aneurysms demonstrated complete clot organization. Neck tissue thickness was higher in Matrix-treated aneurysms at 14 days and 3 months, but not at 6 months. No untoward parent artery stenosis was observed in aneurysms treated with Matrix during follow-up. The angiographic cross-sectional area of the Matrix-treated aneurysms was smaller than those treated with GDC at the 3 months. CONCLUSIONS: Matrix accelerated aneurysm fibrosis and neointima formation without parent artery stenosis. The Matrix system might prevent aneurysmal recanalization after endovascular treatment of cerebral aneurysms.

Absorbable Implants↗