Missing mass effect in biosensor's QCM applications.

Abstract

Nowadays, liquid applications of quartz crystal microbalance (QCM) opened a way for in situ studies of proteins, vesicles and cells adsorbed from the solution onto the QCM surface. The sensitivity of QCM to the viscoelasticity of the adsorbed biomaterial can be a reason of the experimentally observed deviation from a linear dependence of QCM resonant frequency on mass deposition (the so-called Sauerbrey relation) and can limit its application for biosensoring. Presented here rigorous theoretical analysis explains the deviation from ideal mass response of soft overlayers in the contact with liquid. The fundamental result of the theory is the analog of Sauerbrey relation for layered viscous/viscoelastic medium which can be exploited for the correct physical interpretation of QCM experimental data in biofluids, in particular for measurements of the 'true' surface mass of adsorbed biomolecular films. We predict a new physical effect 'missing mass' of the sample in liquid phase measurements and compare the results given by our theory with QCM measurements on supported membranes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M V Voinova, M Jonson, B Kasemo. 2002. Missing mass effect in biosensor's QCM applications.. https://doi.org/10.1016/s0956-5663(02)00050-7

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Three-dimensional porous nano-hydroxyapatite@gelatin composite as efficient adsorbent for uranyl ion removal from low-level radioactive wastewater.

The contamination of water resources by uranyl (UO22+) ions poses significant environmental and health risks, requiring the development of efficient and sustainable remediation strategies. Adsorption-based techniques have emerged as promising approaches in the field of UO22+ removal, but the design of cost-effective, high-capacity, and environmentally friendly adsorbents remains challenging. In this study, a three-dimensional porous nano-hydroxyapatite@gelatin (nHAP@Ge) composite was synthesized through glutaraldehyde cross-linking, combining the structural stability of Ge with the high uranium affinity of nHAP. The optimized nHAP@Ge, with a nHAP:Ge mass ratio of 1:0.5, exhibited exceptional UO22+ removal efficiency (97 %), along with high adsorption capacity (364.03 mg/g). Systematic characterizations using scanning electron microscopy (SEM), thermogravimetric analysis (TGA), Fourier transform infrared (FT-IR) spectroscopy, and X-ray photoelectron spectroscopy (XPS) methods revealed that the porous structure and surface functional groups (-OH, Ca2+, and PO43-) of the material synergistically contributed to binding UO22+ species. Furthermore, the incorporation of nHAP into the Ge framework resulted in enhanced thermal stability while significantly improving the UO22+ adsorption performance. This work presents a scalable, eco-friendly, and recyclable strategy for the effective treatment of uranium-contaminated water, with potential applications in nuclear wastewater treatment and environmental remediation.

Adsorption↗

Determination of albumin concentration by MIP-QCM sensor.

An MIP-QCM sensor able to detect micro-determine albumin concentrations was prepared by imprinting albumin with 3-dimethylaminopropyl methacrylamide-acrylate. The albumin MIP was coated on a QCM Au electrode. The adsorption characteristics of different electrodes, such as Au-OH, Au-COOH, Au-NH2 and Au electrodes, with albumin or mixture was examined. In the tetraethyleneglycol dimethacrylate crosslinking agent system, the adsorption capacity of different Au electrodes is in the order Au-OH > Au-COOH > Au-NH2 > Au. Additionally, the time taken to receive a steady-state frequency is in the order Au-NH2 < Au-OH < Au-COOH < Au. However, in the trimethylolpropane trimethacrylate crosslinking agent system, the adsorption capacity is in the order Au > Au-NH2 > Au-OH > Au-COOH electrode. Hence, the crosslinking agent had a significant effect on the MIP-QCM. On the adsorption selectivity, the albumin MIP-QCM exhibited higher response to albumin, the adsorption mass ratio of cytochrome c:lysozyme:albumin:myoglobin was 160:1:1942:30. On the other hand, in the non-MIP-QCM, the adsorption mass ratio of cytochrome c:lysozyme:albumin:myoglobin was 13:1:249:86. Additionally, a linear fitting was established and a clinical real sample was tested. This novel potential application of molecular imprinting to the recognition element of an MIP-QCM sensor appears to be promising.

Adsorption↗

Immobilization and hybridization by single sub-millisecond electric field pulses, for pixel-addressed DNA microarrays.

Single square voltage pulses applied to buried electrodes result in dramatic rate increases for (1) selective covalent bonding (immobilization) of single-stranded DNA (ssDNA) probes to a functionalized thin film SiO(2) surface on a plastic substrate and (2) hybridization of ssDNA to the immobilized probe. DNA immobilization and hybridization times are 100 ns and 10 micros, respectively, about 10(9) times faster than the corresponding passive reactions without electric field. Surface coverage is comparable. Duration, magnitude and slew rate of the voltage pulse are all key factors controlling the rates of ssDNA immobilization and hybridization. With rise times of 4.5 ns, pulses shorter than 1 ms and voltages below 1V are effective. The ssDNA adsorbed on the surface is reoriented by the rapidly changing electric field. This reduces steric barriers and speeds the immobilization and hybridization reactions. These results open the way for pixel-addressed microarrays driven by silicon microelectronics circuits.

Adsorption↗