PubMed Health⌕ Search

PubMed · 12973795

Recent developments in capillary electrokinetic chromatography with replaceable charged pseudostationary phases or additives.

Abstract

Although electrochromatography in packed beds or monolithic columns has gained enormous interest, techniques based on charged pseudostationary phases like micelles are of high practical importance in electrically driven separation science. However, nonmicellar alternatives, e.g., using charged soluble polymers or smaller additives are still attractive, as they allow high concentrations of organic solvents, and their application is not limited by the critical micellar concentration. This review discusses the developments in the field of electrokinetic chromatography with these additives in the last three years, covering ionic polymeric pseudostationary phases, dendrimers and so-called micelle polymers, but also small molecules which implement separation selectivity due to their specific interaction with the analytes.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Iván Peric, Ernst Kenndler. 2003. Recent developments in capillary electrokinetic chromatography with replaceable charged pseudostationary phases or additives.. https://doi.org/10.1002/elps.200305573

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Uniformly sized molecularly imprinted polymer for atropine and its application to the determination of atropine and scopolamine in pharmaceutical preparations containing Scopolia extract.

A uniformly sized molecularly imprinted polymer (MIP) for atropine has been prepared. The MIP was prepared using 2-(trifluoromethyl) acrylic acid and ethylene glycol dimethacrylate as a functional monomer and cross-linker, respectively, by a multi-step swelling and thermal polymerization method. The selectivity factor, which is defined as the ratio of the retention factors (k) on the molecularly imprinted and non-imprinted polymers, k(imprinted)/k(non-imprinted), was 2.2 for atropine on the MIP. The obtained MIP was applied for the determination of tropane alkaloids (atropine and scopolamine) in a commercial gastrointestinal drug by a column-switching HPLC system, consisting of an MIP material as a pre-column, and a conventional cation-exchange analytical column. An interference peak was observed at the retention time of atropine derived from pre-column. However, since the peak area was less than 0.5% the peak area of atropine of a standard solution under the analytical conditions of this study (0.2 microg of atropine was loaded), this interference was negligible in the determination of atropine. On the other hand, no interference peak was observed at the retention time of scopolamine. Calibration curves of atropine and scopolamine showed good linearity in the range of 0.02-0.9 microg/ml (r=0.9999) and 0.003-0.09 microg/ml (r=0.9998), respectively. The mean recoveries of atropine and scopolamine from a placebo pharmaceutical preparation sample were 98.9 and 99.9%, respectively. The intra-day precision (measured by relative standard deviation, R.S.D. (%)) of both ingredients was less than 2.0%. The optimized column-switching system was applied successfully to the determination of atropine and scopolamine in a commercial gastrointestinal drug.

Acrylates↗

Practical Rh(I)-catalyzed asymmetric hydrogenation of beta-(acylamino)acrylates using a new unsymmetrical hybrid ferrocenylphosphine-phosphoramidite ligand: crucial influence of an N-H proton in the ligand.

[reaction: see text] Excellent enantioselectivities and high turnovers (S/C = 5000) were achieved in the Rh(I)-catalyzed asymmetric hydrogenation of both beta-aryl- and beta-alkyl-beta-(acylamino)acrylates with a new unsymmetrical hybrid ferrocenylphosphine-phosphoramidite ligand, and the presence of an N-H proton in the ligand was demonstrated to have a crucial role in the enantioselectivity.

Acrylates↗