PubMed Health⌕ Search

PubMed · 1437203

A multisensor solid-state pressure manometer to identify the level of collapse in obstructive sleep apnea.

Abstract

The cause of failure after uvulopalatopharyngoplasty (UPPP) in idiopathic obstructive sleep apnea (OSA) is poorly understood, but has been speculated to be due, in part, to persistent collapse in the lower oropharynx. In order to determine the specific level of upper airway obstruction during sleep, a multisensor pressure catheter has been developed with five solid-state ultraminiature sensors. Four sensors in the pharynx simultaneously measure multiple pressure levels, with no need to move the catheter during sleep. One distal esophageal port measures the respiratory effort. To evaluate the use of this catheter, manometry in twelve patients was reviewed and compared the use of this catheter, manometry in twelve patients was reviewed and compared to simultaneous videoendoscopy. The initial site of obstruction was the palate in nine patients (75%) and the tongue base in three (25%). Three patients with initial obstruction at the palate manometrically demonstrated distal obstruction on subsequent occluded breaths. Furthermore, simultaneous videoendoscopy in four patients with a palatal level of obstruction also identified marked near-total visual collapse without obstruction of the lower oropharynx that was not identified by pharyngeal manometry. The endoscopy revealed that at the initial site of obstruction, collapse appeared to have occurred passively during expiration and not on inspiration. Inferior to the site of manometric obstruction, collapse occurred during inspiration associated with increased negative inspiratory pressures. These results demonstrate that a multisensor pressure catheter can objectively identify the level of obstruction during sleep.(ABSTRACT TRUNCATED AT 250 WORDS)

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B T Woodson, M R Wooten. 1992. A multisensor solid-state pressure manometer to identify the level of collapse in obstructive sleep apnea.. https://doi.org/10.1177/019459989210700507

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Immune heparin-induced thrombocytopenia resulting from preceding exposure to heparin catheter flushes.

Immune heparin-induced thrombocytopenia (HIT) is a life-threatening adverse effect of heparin. It can result from any type of heparin exposure and by any route of administration; however only a few cases are reported after exposures to small quantities of heparin from catheter flushes. The major clinical problem associated with HIT is thrombosis. Early detection and institution of alternative, non-heparin anticoagulation are important. We report a patient with HIT associated with use of therapeutic-dose unfractionated heparin in whom immune sensitization to heparin was triggered by two 500-unit exposure to UFH associated with intravascular catheter flushing for antineoplastic chemotherapy in a patient with colon adenocarcinoma.

Catheterization↗