PubMed Health⌕ Search

PubMed · 15101587

Functionally gradient bonelike hydroxyapatite coating on a titanium metal substrate created by a discharging method in HBSS without organic molecules.

Abstract

PURPOSE: This study evaluated the quality of coatings on titanium surfaces prepared by discharging in Hanks' balanced salt solution without organic molecules (HBSS-). MATERIALS AND METHODS: 10 x 10 x 1.0-mm titanium plates were used as cathodes of a coating device developed in the laboratory and immersed in HBSS-. A piece of platinum foil was used as a counterelectrode. Discharging was maintained at 1 A and 10 V (416 mA/cm2) for periods of 90, 270, and 540 seconds. Crystal phases of the coatings were identified by x-ray diffraction (XRD) and Fourier transform infrared spectroscopy (FTIR). In addition, the surface characterization and Ca/P atomic ratio of the titanium surfaces were determined by x-ray photoelectron spectroscopy (XPS). Furthermore, the surface topography, the thickness of the coatings, and the bonds between coatings and titanium substrates were observed by scanning electron microscopy. RESULTS: The FTIR and XRD studies demonstrated that the deposits on the titanium after 540 seconds of discharging were crystalline hydroxyapatite. In addition, the thickness of the titanium suboxide layer increased during discharging. The XPS studies indicated that after 540 seconds of processing, the mean Ca/P ratio of the coatings on the titanium was 1.71, which is similar to that of human bone. DISCUSSION: In addition, the replacement of sodium ions with calcium ions seemed important for the promotion of crystallization of the coating. Furthermore, the XPS studies demonstrated that the coatings had a gradient function. Scanning electron microscopy showed that adhesion between coatings and the titanium substrate was close. The coatings were approximately 1 microm thick. CONCLUSION: These findings suggest that a very thin crystalline bonelike hydroxyapatite coating with a gradient function could be prepared on a titanium metal substrate in HBSS- by a discharging method.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Yo Shibata, Hidetoshi Takashima, Hiroki Yamamoto, Takashi Miyazaki. Functionally gradient bonelike hydroxyapatite coating on a titanium metal substrate created by a discharging method in HBSS without organic molecules.. https://pubmed.ncbi.nlm.nih.gov/15101587/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Effect of capillary condensation on friction force and adhesion.

Friction force measurements have been conducted with a colloid probe on mica and silica (both hydrophilic and hydrophobized) after long (24 h) exposure to high-humidity air. Adhesion and friction measurements have also been performed on cellulose substrates. The long exposure to high humidity led to a large hysteresis between loading and unloading in the friction measurements with separation occurring at large negative applied loads. The large hysteresis in the friction-load relationship is attributed to a contact area hysteresis of the capillary condensate which built up during loading and did not evaporate during the unloading regime. The magnitude of the friction force varied dramatically between substrates and was lowest on the mica substrate and highest on the hydrophilic silica substrate, with the hydrophobized silica and cellulose being intermediate. The adhesion due to capillary forces on cellulose was small compared to that on the other substrates, due to the greater roughness of these surfaces.

Adhesiveness↗

Evaluation of bond strength of soft relining materials to denture base polymers.

OBJECTIVES: To evaluate the initial bonding properties of recently and previously introduced soft relining materials to denture base polymers with different polymerization techniques and different water content. METHODS: The initial tensile bond strength of 10 soft liners (Mollosil Plus, Dentusil, Ufi gel Soft, GC Reline Soft, Silagum Comfort, Vertex Soft, Astron Soft, Molloplast B, Flexacryl Soft, Triad Resiline) to three denture base polymers (Paladon 65, Palapress Vario, Ivocap Plus) were assessed with a modified method. Paladon 65 specimens immersed in water for 3 months were also used to test the effect of water content of denture base polymer on bond strength results. After testing, a visual examination of the fracture surfaces and a SEM investigation of the interface structure were performed. Tensile strength of each soft liner material was also tested. Data were analyzed statistically by two-way ANOVA (alpha = 0.05). RESULTS: Significant differences were found among tensile bond strength results (P < 0.05). Vinyl poly(organosiloxane) soft liners (Mollosil Plus, Dentusil, Ufi gel Soft, GC Reline Soft, Silagum Comfort) and a plasticized PMMA soft liner (Vertex Soft) gave statistically similar bond strength results for different denture base polymers (P>0.05). For the other materials used (Astron Soft, Molloplast B, Flexacryl Soft, Triad Resiline), different denture base polymers caused significantly different results (P < 0.05). Poly(organosiloxane) based materials gave slightly higher bond strength results with water immersed specimens than with the dry specimens. SIGNIFICANCE: A wide variety of newly formulated soft liners used in this study gave comparable or better bond strength results compared to Molloplast B.

Adhesiveness↗

Flat and sigmoidally curved contact zones in vesicle-vesicle adhesion.

Using the membrane-bending elasticity theory and a simple effective model of adhesion, we study the morphology of lipid vesicle doublets. In the weak adhesion regime, we find flat-contact axisymmetric doublets, whereas at large adhesion strengths, the vesicle aggregates are nonaxisymmetric and characterized by a sigmoidally curved, S-shaped contact zone with a single invagination and a complementary evagination on each vesicle. The sigmoid-contact doublets agree very well with the experimentally observed shapes of erythrocyte aggregates. Our results show that in identical vesicles with large to moderate surface-to-volume ratio, the sigmoid-contact shape is the only bound morphology. We also discuss the role of sigmoid contacts in the formation of multicellular aggregates such as erythrocyte rouleaux.

Adhesiveness↗