Ghosting caused by bulk charge trapping in direct conversion flat-panel detectors using amorphous selenium.

Abstract

Direct flat-panel detectors using amorphous selenium (a-Se) x-ray photoconductors are gaining wide-spread clinical use. The goal of our investigation is to understand the physical mechanisms responsible for ghosting, i.e., x-ray induced change in sensitivity that results in image persistence, so that the knowledge can be used to consistently minimize ghosting artifacts in a-Se flat-panel detectors. In this paper we will discuss the effect on x-ray sensitivity of charge trapping in a-Se, which is the dominant source for ghosting in a-Se flat-panel detectors. Our approach is to correlate ghosting in electroded a-Se detectors with the trapped charge concentration measured by the "time-of-flight" (TOF) method. All measurements were performed as a function of radiation exposure X of up to approximately 20 R at electric field strength's of E(Se)=5 and 10 V/microm. The results showed that the x-ray sensitivity decreased as a function of X and the amount of ghosting decreased with increasing E(Se). The shape of the TOF curves changed as a result of irradiation in a manner indicating trapped electrons in the bulk of a-Se. The density of trapped electrons n(t) increases as a function of X. A method was developed to determine the values of n(t) in the bulk of a-Se from the TOF measurements, and to predict the corresponding change in x-ray sensitivity. Our results showed that a recombination coefficient consistent with that predicted by Langevin produced good agreement between calculated and measured x-ray sensitivity changes. Thus it can be concluded that the trapping of electrons in the bulk of a-Se and their subsequent recombination with x-ray generated free holes is the dominant mechanism for ghosting in a-Se.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Wei Zhao, G DeCrescenzo, Safa O Kasap, J A Rowlands. 2005. Ghosting caused by bulk charge trapping in direct conversion flat-panel detectors using amorphous selenium.. https://doi.org/10.1118/1.1843353

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Striping artifact removal in VisiumHD data through nuclear counts modeling.

MOTIVATION: 10x Genomics VisiumHD enables spatial transcriptomics at 2 µm × 2 µm resolution but exhibits slide-specific, non-periodic striping artifacts due to lane-width variability. These multiplicative row/column effects distort bin total counts and can bias downstream analyses. The state-of-the-art destriping approach is the normalization procedure used as a preprocessing step in bin2cell; it applies sequential high-quantile row- then column-wise normalization, which is asymmetric and can introduce edge effects/macro-stripes and distortions of large-scale total-count structure. RESULTS: We propose a statistical destriping approach that leverages nuclei segmentation from the co-registered H&E image. Assuming transcript abundance is constant within each nucleus, we model bin counts with a negative binomial distribution whose mean is a product of a nucleus-specific concentration and row- and column-specific stripe-factors reflecting lane-width variation. We fit all parameters in a generalized linear modeling framework with cross-validated regularization on stripe-factors and iterative dispersion estimation, and use the fitted parameters to correct the observed counts into a destriped image. On synthetic data with known ground truth, our method improves stripe-factor estimation accuracy and reduces error in corrected counts relative to bin2cell and bin2cell-derived baselines. Across four public VisiumHD slides, it consistently lowers striping intensity while substantially better preserving biological signal present in the large-scale global count structure and avoiding the artifacts introduced by other methods. AVAILABILITY AND IMPLEMENTATION: All source code and links to publicly available data used for this study are available at https://github.com/paolamalsot/destriping-GLM.

Artifacts↗

Impairment of echocardiographic acoustic window caused by breast implants.

Cosmetic breast implants are increasing in popularity. The presence of a breast implant overlying the anterior mediastinal space as a cause of impairment of the echocardiographic acoustic window has not been described previously. Here, we report three cases with significant impairment of echocardiographic acoustic window caused by breast implants. Clinicians should be aware of this interference and women should be informed of this dilemma before considering this cosmetic surgery.

Artifacts↗