PubMed Health⌕ Search

PubMed · 16773299

Stabilization of two-phase octanol/water flows inside poly(dimethylsiloxane) microchannels using polymer coatings.

Abstract

In this paper we present our first results on the realization of stable water/octanol, two-phase flows inside poly(dimethylsiloxane) (PDMS) microchannels. Native PDMS microchannels were coated with high molecular weight polymers to change the surface properties of the microchannels and thus stabilize the laminar flow profile. The polymers poly(2-hydroxyethyl methacrylate), poly(vinyl pyrrolidone), poly(ethylene oxide), poly(ethylene glycol), and poly(vinyl alcohol) were assessed for their quality as stabilization coatings after deposition from flowing and stationary solutions. Additionally, the influence of coating the microchannels homogeneously with a single kind of polymer or heterogeneously with two different polymers was investigated. From the experimental observations, it can be concluded that homogeneous polymer coatings with poly(2-hydroxyethyl methacrylate) and poly(vinyl pyrrolidone) led to the effective stabilization of laminar water/octanol flows. Furthermore, heterogeneous coatings led to two-phase flows which had a better-defined and more stable interface over long distances (i.e., 40-mm-long microchannels). Finally, the partitioning of fuchsin dye in the coated microchannels was demonstrated, establishing the feasibility of the use of the polymer-coated PDMS microchannels for determination of logP values in laminar octanol/water flows.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

H J van der Linden, L C Jellema, M Holwerda, E Verpoorte. 2006-06-14. Stabilization of two-phase octanol/water flows inside poly(dimethylsiloxane) microchannels using polymer coatings.. https://doi.org/10.1007/s00216-006-0526-y

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Study of on-line monitoring of lactate based on optical fibre sensor and in-channel mixing mechanism.

A PDMS-based microfluidic device with integrated optical fibres was developed for online monitoring of lactate. The detection is based on the optical adsorption of the colour solution formed by in-channel mixing of sample and reagent solutions. Computational Fluid Dynamics (CFD) simulation and kinetic study of the colour development were conducted to determine the minimum channel length and optimum residential time for homogenous mixing and maximum optical adsorption respectively. The system was proved to be able to detect lactate with good linearity (R(2)=0.98), response time of about 130 s and estimated limitation of detection (LOD) of 0.52 mM (about 47 mg/L), which is sufficient for a general online lactate detection. Due to the miniaturization of sensing system and micro-scale mixing, higher detection sensitivity (0.15 V/mM) can be realized than the mixing in lab-scale equipments (0.08 V/mM).

Dimethylpolysiloxanes↗

Glass-fiber reinforced poly(acrylate)-based sorptive materials for the enrichment of organic micropollutants from aqueous samples.

A novel and simple approach to sorptive materials for the extraction of organic compounds from environmental samples is presented. It entails the use of glass fiber fabric strips coated with a customized poly(acrylate) (PA) formulation as extraction medium. Analytes were enriched by means of shaking of the PA strip in the sample and then subsequently thermally desorbed and analyzed by GC-MS. The performance of the sorptive materials was evaluated by the enrichment of compounds with different polarities (phenols, hexachlorobenzene and hexachlorocyclohexanes) from water samples. Parameters that affect the extraction process such as pH, ionic strength of the solvent, mixing mechanism, extraction time and desorption conditions were investigated. The extraction abilities of the PA extraction medium were compared with that of commercially available poly(dimethylsiloxane) (PDMS) Twisters. The results revealed that the new material shows higher affinity for phenolic compounds presumably due to the presence of polar groups. The partition coefficients for the PA strips estimated in this work were up to 15 times higher than for the PDMS Twister, resulting in higher recoveries and lower detection limits. The method was applied for the quantification of the aforementioned compounds in contaminated surface water samples from Bitterfeld (Germany). Using both PA strips and PDMS Twisters, good agreement of the extraction data was achieved.

Dimethylpolysiloxanes↗