Comparative evaluation of local and international reference databases for forearm densitometry: different impacts on diagnostic decisions.

Abstract

Reference databases play a key role in the management of osteoporosis. The aim of this preliminary study was to compare the diagnostic consequences of using either an international or a local reference database in peripheral densitometry. For this purpose, standard curves for bone mineral density (measured by dual-energy X-ray absorptiometry at the distal and proximal forearm) were generated for healthy Hungarian men and women. In total, 303 healthy volunteers of both sexes (age range: 20-94 yr) were recruited from four osteoporosis centers. Subjects with medical conditions or taking medication affecting the bone metabolism were excluded. Bone densitometry was performed with pDEXA (Norland-Stratec, Fort Atkinson, WI) devices in each center after cross-calibration of the machines. The precision error of the forearm measurement was also determined (<1% in vitro, and 1.2-2.5% in vivo). In females, the peak forearm density was detected in the 30-39-yr group. The density decreased by 8% per 5 yr in early postmenopausal females, and by 10% per 10 yr in late postmenopausal females. In males, the highest bone mineral density was found in the 30-39-yr group for the distal forearm, but 1 decade later for the proximal site. Subsequently, a 5% decrease in density occurred per 10 yr, except in the 8th decade, in which a 20% decrease was demonstrated. One thousand four hundred thirty-four patients with suspected osteoporosis were classified according to the forearm density T-scores using both the new Hungarian reference database and the international database provided by the manufacturer. Comparison of the results measured at the distal forearm with the two different databases led to similar outcomes. However, at the proximal site, one fifth of the female patients were reclassified from the low-density group to the normal group using the domestic normative database. An opposite difference was observed for the males: use of the Hungarian reference data resulted in 40% more men being categorized in the low-density group than when the international normal database was applied. Our results suggest that not only geographic differences, but also the reference database used, can influence the prevalence of the diagnosis of osteoporosis. Further data are currently being collected to increase the statistical power of the study.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

Szilvia Mészáros, Péter Berko, György Genti, Eva Hosszú, Béla Keszthelyi, István Krasznai, Ferenc Teremi, Péter Vargha, Csaba Horváth. 2006-08-28. Comparative evaluation of local and international reference databases for forearm densitometry: different impacts on diagnostic decisions.. https://doi.org/10.1016/j.jocd.2006.06.004

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A repeated measures concordance correlation coefficient.

The concordance correlation coefficient is commonly used to assess agreement between two raters or two methods of measuring a response when the data are measured on a continuous scale. However, the situation may arise in which repeated measurements are taken for each rater or method, e.g. longitudinal studies in clinical trials or bioassay data with subsamples. This paper proposes a coefficient for measuring agreement between two raters or two methods of measuring a response in the presence of repeated measurements. We illustrate the methodology with examples comparing (1) 1-hr versus 2-hr blood draws for measuring cortisol in an asthma clinical trial and (2) two measurements of percentage body fat, from skinfold calipers and dual energy X-ray absorptiometry.

Absorptiometry, Photon↗

Crystallization and preliminary X-ray analysis of a domain in the Runx2 transcription factor that interacts with the 1alpha,25 dihydroxy vitamin D3 receptor.

The Runx2 transcription factor is a key regulator of osteoblast differentiation. In response to 1alpha,25 dihydroxy vitamin D3, Runx2 may interact with the 1alpha,25 dihydroxy vitamin D3 receptor (VDR) in the promoter of target genes, producing a synergic activation of their transcription. Previous studies have suggested that the motifs responsible for the VDR-Runx2 interaction are contained within the 230-361 domain of Runx2. In this work, we confirmed by GST-pull down that Runx2(I(209-361)) is sufficient to interact with the VDR. To obtain structural information, GST-Runx2(I(209-361)) protein was overexpressed in Escherichia coli, purified and crystallized using the hanging-drop vapor-diffusion method and polyethyleneglycol as a precipitant. The crystals were found to diffract to a maximum resolution of 2.7 A and a complete data set to a 3.3 A resolution was collected and analyzed. The crystals belong to the tetragonal system, with a space group P4 and unit-cell parameters of a = b = 90.8, and c = 57.2 A. The presence of a monomer of the recombinant GST-Runx2(I(209-361)) in the asymmetric unit gives a V(M) of 2.7 A(3) Da(-1) and a solvent content of 54.8%.

Absorptiometry, Photon↗

Quantifying the treatment effect explained by markers in the presence of measurement error.

Surrogate markers or intermediate markers are important in identifying subjects with high risk of a serious disease or for monitoring disease progression of a subject on treatment. Quantifying the proportion of treatment effect (PTE) explained by markers has been studied extensively. Due to reasons such as biological variation, limited machine precision, etc. markers are generally measured with error. The estimated PTE ignoring the measurement error could be biased, which may lead to incorrect conclusions. In this article, we adjust for the measurement error using regression calibration to construct a less biased estimator of excess relative odds, a quantity to measure the treatment effect explained by markers. The method is applied to data from a clinical study in osteoporosis.

Absorptiometry, Photon↗