Methods for non-invasive detection of ventricular late potentials--a comparative multicenter study.

Abstract

To evaluate the methodological problems of the non-invasive registration of late potentials the results obtained with four different averaging devices in the same 109 patients were compared. The high-resolution ECG was obtained from the body surface, high-gain amplified and filtered. With the averaging technique, the improved signal-to-noise ratio was able to detect low-amplitude cardiac activity. The incidence of late potentials detected with the four averaging systems, whose characteristics are described, ranged between 12% and 21%. Corresponding positive results were obtained in 5.5%, corresponding negative results in 68.8%. The reasons for differing results were mainly due to differences in visual or automatic interpretation of the registered fractionated electrical cardiac activity. Additionally, the determination of the end of QRS using the QRS width, obtained from reference leads, may influence the specificity of the methods.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Oeff, E R von Leitner, R Sthapit, G Breithardt, M Borggrefe, U Karbenn, T Meinertz, R Zotz, W Clas, V Hombach. 1986. Methods for non-invasive detection of ventricular late potentials--a comparative multicenter study.. https://doi.org/10.1093/oxfordjournals.eurheartj.a061953

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

[CME-ECG 2].

Explore the source record for details and available documents.

Cardiac Complexes, Premature↗

Extrasystoles: side effect of kangaroo care?

OBJECTIVE: To present an unpublished reason for an arrhythmic electrocardiogram (ECG) recording during kangaroo care in a preterm infant. DESIGN: Case report. PATIENT: Preterm infant. MEASUREMENTS AND MAIN RESULTS: A preterm infant exhibited cardiac arrhythmia on the ECG monitor during kangaroo care, leading to interruption of kangarooing. Arrhythmia disappeared after placing the baby back into the incubator. The most likely reasons for arrhythmia were excluded. However, arrhythmia reappeared upon continuation of kangaroo care. ECG monitoring revealed the reason for the monitoring error. CONCLUSIONS: ECG monitoring during kangaroo care should cause error because of superimposed electric activity from the parent. Oxygen saturation represents a more reliable method of monitoring during kangaroo care.

Cardiac Complexes, Premature↗