PubMed HealthSearch

PubMed · 3974529

Two-film brachytherapy reconstruction algorithm.

Abstract

We have developed a new isocentric two-film reconstruction algorithm for brachytherapy seed and needle implants. The algorithm has no requirements that the two films be orthogonal, symmetric, or even be taken in a transverse plane. In addition, there is no requirement that the two films even have the same number of images. We have found removal of these usual constraints useful for head and neck implants where images are often obscured by patient anatomy. The inherent image matching ambiguities associated with traditional two-film techniques are minimized by considering the image end points, rather than just the image centroids. For two films, the new algorithm, which considers all image combinations at one time, matches all the end-point images on one film with those on the other, and then reconstructs the end-point positions of the seeds. The algorithm minimizes the difference between the actual images and the projected images from the reconstructed seeds. The new two-film image matching problem is shown to be equivalent to the well-known assignment problem. For an implant of N seeds, this equivalence allows the two-film problem to be solved by an algorithm (ACM algorithm 548) that scales with a polynomial power of N, rather than N! as is usually assumed. An implant of N seeds can be matched and reconstructed in approximately (N/20)2s on a VAX 11/780.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

R L Siddon, L M Chin. Two-film brachytherapy reconstruction algorithm.. https://doi.org/10.1118/1.595738

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Prospective, conservative management of localized prostate cancer.

BACKGROUND: Currently, no randomized trials of the various treatment options for localized prostate cancer have been reported. Therefore, radical prostatectomy and external irradiation are offered as the primary management options and are thought by many to be curative. METHODS: All patients in this series with a confirmed diagnosis of cancer of the prostate, localized, were given the option of expectant management in addition to the popular ones. Therefore, 233 patients with localized Stage A and B cancer were observed prospectively and conservatively for a period of 22 years, with a management plan of watchful waiting for most patients until signs and/or symptoms of disease activity occurred. In 44 patients interstitial I-125 irradiation implantation and pelvic lymphadenectomy were performed in those who received surgical intervention. RESULTS: No patient received external irradiation or radical prostatectomy in this series. The overall survival of patients was not statistically different from the United States life-tables probability for men of similar ages when the study ended for reporting purposes in June 1989. Exclusive of the 6 patients lost to follow-up, 52 patients survived less than 3 years, whereas 181 patients have survived more than 3 years. CONCLUSIONS: Because of the favorable results in this expectant management study, it appears prudent that all patients with localized prostate cancer should have this management option as well as radical surgery or external irradiation.

Brachytherapy

[Endobronchial intraluminal brachytherapy for patients with tracheobronchial carcinoma with high dose-rate 192-Iridium remote afterloading method].

Endobronchial intraluminal brachytherapy was conducted for 5 patients with tracheobronchial carcinoma using 192Iridium high dose-rate afterloading machine (microSelectron HDR) and guide tubes of 1.9 mm in outer diameter. Four patients with bronchial non-small cell carcinoma and one with tracheal adenocarcinoma were applied, and a dose of 6 Gy/Fr. at points 1 cm from the source once a week, and a cumulative dose of 18 Gy/3 Fr. was delivered. Guide tubes could be placed up to 3 tubes via the vocal airway, and new computer planning system could afford to calculate dose from independent lining of the source into optimization. This could be done with safety, and no remarkable acute side effects were observed attributable to this method.

Brachytherapy