PubMed Health⌕ Search

PubMed · 4009509

External knee joint design based on normal motion.

Abstract

There are several advantages to accurate reproduction of knee motion in an external joint assembly such as a knee brace: reduction of pistoning forces, better ligament protection, kinematic compatability. The geometry and kinematics of the normal human knee were studied and the results applied to external joint design. Geometrically, the posterior portions of the femoral condyles were found to be spherical in shape. These spherical surfaces are projected in sagittal plane radiographs as circles with center points coincident with those of the spheres. A line connecting these centers defines an axis system and enables three-dimensional orientation of the femur on the tibia to be determined using sagittal-plane radiographs. Knee kinematics was determined as a function of flexion angle for 14 fresh cadavers and 8 volunteers. Results were in the form of eulerian rotations and displacements. The data were normalized to the size of the average knee and the results from the 22 trials were averaged. The most obvious motion was internal rotation of the tibia with flexion; however, varus rotation and posterior translation of the origin were also evident. An external joint system was then designed to mimic "average" knee motion during flexion. The joints have been incorporated into a knee brace, and clinical evaluation has begun. Other applications include cast bracing and hinge distraction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

P S Walker, H Kurosawa, J S Rovick, R A Zimmerman. 1985. External knee joint design based on normal motion.. https://doi.org/10.1682/jrrd.1985.01.0009

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Clinical, echocardiographic, and biomechanical differences in mitral valve prolapse affecting one or both leaflets.

Mitral valve prolapse (MVP) is the most common cause of severe mitral regurgitation necessitating surgical correction. Unileaflet prolapse (ULP), usually involving the posterior leaflet, is more common than bileaflet prolapse (BLP), which is more difficult to repair. Little is known about clinical, echocardiographic, and biomechanical differences between ULP and BLP. In this study, biomechanical testing was performed on mitral valve leaflets and chordae obtained at operation for severe mitral regurgitation. Preoperative clinical characteristics and echocardiographic measurements were obtained on surgical patients (ULP = 88, BLP = 37). Men outnumbered women by a factor of 4:1 in ULP, and by 3:1 in BLP. Patients with BLP were younger (53.2 +/- 1.7 vs 59.5 +/- 1.1 years) than those with ULP, and this difference was greater in women (48.9 +/- 2.5 vs 62.9 +/- 2.2 years). BLP patients were less likely to be hypertensive, and more likely to undergo valve replacement rather than repair. Echocardiography showed that BLP leaflets were longer and thicker than ULP leaflets. The severity of mitral regurgitation was similar in both groups, although ULP patients had a much higher incidence of flail leaflets (45% vs 5% in BLP). Mechanical strength of chordae was greater in BLP than in ULP, although leaflet strength was similar. The increased chordal strength in BLP may be responsible for less flail. In patients with MVP and severe mitral regurgitation requiring surgery, ULP and BLP are distinct entities with substantial differences in the population affected, in echocardiographic manifestations including prevalence of flail, in chordal mechanics, and in the likelihood of surgical repair.

Biomechanical Phenomena↗

New approach to the urogynecological ultrasound examination.

OBJECTIVE: To evaluate a new system for the ultrasound evaluation of urethral mobility. STUDY DESIGN: We studied the structure of interpubic disc and found landmarks that can be used to align different images and set up an universal system of coordinates. The method for capturing and post-processing of the introital ultrasound examination is described. The urethra in its entire course is evaluated. Ten patients were examined and some important points at the interpubic disc and the urethra were traced to assess the reproducibility of the method. RESULTS: The mean intra-observer difference for x and y coordinates were 1.88 mm (S.D. 1.53) and 2.00 mm (S.D. 1.54), respectively. The inter-observer difference was 2.30 mm (S.D. 1.64) and 2.50 mm (S.D. 1.79), respectively for x and y coordinates. CONCLUSION: The method shows good inter- and intra-observer correlation and presents data that can be further used for biomechanical analysis.

Biomechanical Phenomena↗

Corns and calluses resulting from mechanical hyperkeratosis.

The formation of corns and calluses can be caused by mechanical stresses from faulty footgear (the wearing of poorly fitting shoes), abnormal foot mechanics (deformity of the foot exerting abnormal pressure), and high levels of activity. Corns and calluses result from hyperkeratosis, a normal physiologic response of the skin to chronic excessive pressure or friction. Treatment should provide symptomatic relief and alleviate the underlying mechanical cause. The lesions will usually disappear following the removal of the causative mechanical forces. Most lesions can be managed conservatively by the use of properly fitting shoes and padding to redistribute mechanical forces. Surgery is only indicated if conservative measures fail and should be aimed at correcting the abnormal mechanical stresses.

Biomechanical Phenomena↗