PubMed Health⌕ Search

PubMed · 5516925

[Radiographic technic using programming of radiographic data].

Abstract

The source did not provide an abstract. Follow the original record for more information.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

J Kollath, G Jötten. 1970. [Radiographic technic using programming of radiographic data].. https://pubmed.ncbi.nlm.nih.gov/5516925/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

An automatic 96-well solid phase extraction and liquid chromatography-tandem mass spectrometry method for the analysis of morphine, morphine-3-glucuronide and morphine-6-glucuronide in human plasma.

A bioanalytical method using automated sample transferring, automated solid phase extraction (SPE) and liquid chromatography-tandem mass spectrometry (LC-MS-MS) was developed for morphine (MOR), and its metabolites morphine-3-glucuronide (M3G) and morphine-6-glucuronide (M6G) in human plasma. Samples of 0.25 ml were transferred into 96-well plate using automatic liquid handler (Multiprobe II). Automated SPE was carried out on a 96-channel programmable liquid handling workstation (Quadra 96) using a C(18) sorbent. The extract was injected onto a silica column using an aqueous-organic mobile phase. The chromatographic run time was 3.5 min per injection, with retention times of 1.5, 2.0 and 2.6 min for MOR, M6G, and M3G, respectively. The detection was by monitoring MOR at m/z 286-->152, M6G and M3G at m/z 462-->286. The deuterated internal standards were monitored at m/z 289-->152 for MOR-d(3), and m/z 465-->289 for M6G-d(3) and M3G-d(3). The standard curve range was 0.5-50 ng ml(-1) for MOR, 1.0-100 ng ml(-1) for M6G, and 10-1000 ng ml(-1) for M3G. The inter-day precision and accuracy of the quality control samples were <8% relative standard deviation (RSD) and <7% relative error (RE) for MOR, <5% RSD and <2% RE for M6G, and <2% RSD and <4% RE for M3G.

Automation↗

Automated data processing on beamline FIP (BM30A) at ESRF.

Automation of protein crystallography synchrotron beamlines is becoming necessary to face challenging structural genomics projects. In this context, a program has been developed that processes diffraction frames using popular software but analyzes statistics and makes choices the way crystallographers usually do. This program includes the classical peak search, indexing, integration, scaling and anomalous signal analysis. The result, comparable with that obtained by standard users, is rapidly available, providing the required information for a more efficient use of the beam time.

Automation↗

Automated dynamic sampling system for the on-line monitoring of biogenic emissions from living organisms.

An automated system for continuous on-line monitoring of biogenic emissions is presented. The system is designed in such a way that volatiles, emitted as reaction to biotic or abiotic stress, can be unequivocally elucidated. Two identical sampling units, named target and reference bulb, are therefore incorporated into the system and consecutively analyzed in monitoring experiments. A number of precautions were considered during these experiments to avoid the application of unwanted stress onto both organisms. Firstly, the system is constructed in such a way that both bulbs are continuously flushed, i.e. before, during and after analysis, with high purity air to avoid any accumulation of emitted volatiles. Moreover, the air is pre-humidified by bubbling it through water to sustain the biological samples for longer periods in the in vitro environment. Sorptive enrichment on polydimethylsiloxane (PDMS) was used to trap the headspace volatiles. The hydrophobic nature of this material permitted easy removal of trapped moisture by direct flushing of the sampling cartridge with dry air before desorption. The system was used to monitor the emissions from in vitro mechanically wounded ivy (Hedera helix) and of in vitro grown tomato plants (Lycopersicon esculentum Mill.) upon cotton leafworm (Spodoptera littoralis) feeding. Differences in light and dark floral emissions of jasmine (Jasminum polyanthum) were also studied.

Automation↗