PubMed Health⌕ Search

PubMed · 6529141

Upper urinary tract compliance: its importance in obstructive hydronephrosis.

Abstract

Improvements in diagnostic modalities over the last 15 years have meant that obstruction can now be diagnosed accurately in dilated upper tracts. However, it is no longer sufficient to diagnose obstruction in a hydronephrotic kidney; it is necessary to determine the likelihood of functional deterioration in that kidney by measuring its elastic distensibility (compliance). 111 pressure flow studies have been reviewed in an attempt to measure the compliance of each upper tract under study and to assess its clinical implications. Good compliance was seen in 64 dynamically unobstructed renal units as well as in 16 obstructed systems. These 16 obstructed systems with good compliance had less significant degrees of obstruction than a group of 31 obstructed systems with poor compliance. Obstruction with good compliance was associated with preservation of renal function as measured by diuresis renography whilst impaired function was seen in systems with obstruction and poor compliance. Systems with good compliance and obstruction may not necessarily need surgery to relieve obstruction but instead could be managed by avoiding a high fluid intake which is liable to produce a pressure rise in the kidney. Poor compliance or functional deterioration are indications for immediate relief of the obstruction.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

K N Bullock, R H Whitaker. 1984. Upper urinary tract compliance: its importance in obstructive hydronephrosis.. https://pubmed.ncbi.nlm.nih.gov/6529141/

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

A rigorous method for evaluation of the 6D compliance of external fixators.

External fixators are standard devices to stabilize bone fractures and their compliance aims at producing an interfragmentary motion that promotes rapid and successful healing. While evaluation of their axial compliance is a routine test, the quantification and interpretation of their full 6 x 6 compliance matrix is an extensive and delicate task. In this context, the objective of this study was to develop, validate and demonstrate the potential of a rigorous method to quantify their 6 x 6 compliance matrix. An experimental system was developed to apply six independent static forces and moments to an external fixator in the field of view of two infrared cameras quantifying the induced motion. The system was then tested with a calibration structure which compliance could be calculated analytically and numerically. Finally, the system was applied to compare three configurations of a commercial external wrist fixator. The results of the method proved to be reproducible and highly consistent with the linear elasticity theory in the physiological range of small deformations. A rigorous method for evaluation of the 6D compliance becomes therefore available for research in mechanobiology of fracture healing by external fixation.

Compliance↗

Fatigue of packable dental composites.

OBJECTIVE: The purpose of the study was to measure the fatigue properties of four dental resin composites using a dynamic mechanical analysis and to relate the results with viscoelastic properties. METHODS: Dynamic torsional loading was conducted at resonance at 30-50Hz. Specimens were thoroughly cured and tested dry at 21 degrees C. RESULTS: All of the specimens showed a loss of strength following repeated stress, due to material fatigue. The material with the highest shear modulus had the lowest damping and the highest fatigue strength. SIGNIFICANCE: Dental composites exhibit a modest loss of strength due to fatigue. Since mastication involves many cycles of stress during the life of a restoration, fatigue properties should be taken into account in restoration design.

Compliance↗