Between-method correlation in quantifying internal carotid stenosis.

Abstract

BACKGROUND AND PURPOSE: The degree of internal carotid stenosis has emerged as the most important predictor of ischemic stroke in extracranial carotid artery disease. The purpose of this study was to assess the validity of the noninvasive techniques for quantifying internal carotid stenosis with respect to the accepted standard of intra-arterial angiography. METHODS: We measured the maximum percentage reduction in luminal diameter on the intra-arterial digital subtraction angiograms of 56 symptomatic patients with extracranial internal carotid stenosis (n = 77) or occlusion (n = 20). These data were compared with independent measurements based on continuous-wave Doppler ultrasonography, pulsed-wave Doppler spectrum analysis, color Doppler-assisted duplex imaging, and magnetic resonance angiography. RESULTS: Correlations with intra-arterial angiography were equally strong (r > .90) for magnetic resonance angiography, continuous-wave Doppler, and color duplex analysis. Positive and negative predictive values for (therapeutically relevant) 70% to 99% stenosis were higher for continuous-wave Doppler (.82, .97) and color duplex (.84, .98) than for magnetic resonance angiography (.79, .81). Also, accuracy in quantifying high-grade stenosis was better for both of these ultrasonographic techniques, mainly due to the frequent occurrence of a "flow gap" on the magnetic resonance angiograms. Continuous-wave Doppler and magnetic resonance angiography, but not color duplex, failed to detect slow residual arterial flow in one and two cases of symptomatic "pseudo-occlusion" of the internal carotid, respectively. CONCLUSIONS: (1) Several noninvasive methods compare well with intra-arterial angiography in identifying and quantifying high-grade internal carotid stenosis; (2) the use of these noninvasive methods may suffice for treatment decisions; and (3) because residual between-method disagreement is partly explained by principles of physics, the validity of continuous-wave Doppler and color duplex in quantifying 60% to 99% stenosis is likely to be underestimated by correlation with intra-arterial angiography.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Sitzer, G Fürst, H Fischer, M Siebler, T Fehlings, A Kleinschmidt, T Kahn, H Steinmetz. 1993. Between-method correlation in quantifying internal carotid stenosis.. https://doi.org/10.1161/01.str.24.10.1513

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Using flow relaxography to elucidate flow relaxivity.

We have investigated the theoretical and experimental linear dependence of the reciprocal of the apparent longitudinal relaxation time [(T*1)-1] of the NMR signal from spins in a flowing fluid on the volume flow rate, Fv, the so-called inflow effect. We refer to the coefficient of this dependence as the longitudinal flow relaxivity, r1F. A very simple model predicts that, under a range of conditions pertinent to modern flow studies and perfusion imaging experiments, r1F is controlled by the volume of the fluid in which the magnetization is perturbed by pulsed RF inversion or saturation, not the detection volume, and that it can be approximated as the reciprocal of half of the inversion volume. Phantom sample experiments, using a new, quantitative approach that we call flow relaxography, confirm the general predictions of this simple model. There are two intriguing implications of these findings for general NMR flow studies as well as for medical applications. It should be possible to vary the value of r1F by simply (noninvasively) adjusting the inversion slice thickness, and thus measure the value of (blood 1H2O, for example) Fv in a vessel without changing Fv, from the resultant varying T*1 values. Also, it should be possible to extrapolate to the intrinsic T1 value of the fluid signal (as if it were stationary), without altering or stopping the flow. Again, these are quite successful in phantom sample studies. Imaging versions of the flow relaxographic experiments are also possible. The twin goals of flow studies in medical MRI are the quantitative discrimination of the signals from flowing and nonflowing spins, and the accurate measurement of the flow rate of the former.

Blood Flow Velocity

Amplitude-coded color doppler: clinical applications.

Amplitude-coded color Doppler sonography (ACD) has become an useful adjunct to gray-scale US and conventional color Doppler sonography (CD) for the assessment of vascular diseases and pathologic conditions that might affect or alter tissue vascularization or perfusion. Basically, all US units that generate conventional color Doppler information through autocorrelation technique are capable of displaying ACD. This technique is also referred to as power Doppler, amplitude-mode color Doppler US, color Doppler energy (CDE), or US angiography. Amplitude-coded color Doppler sonography has already emerged as a valuable adjunct to conventional CD, particularly for evaluating flow in parts of the body where CD signal is weak because of slow flow, small blood vessels, or both.

Blood Flow Velocity

Diagnosis of fetal pulmonary hypoplasia by measurement of blood flow velocity waveforms of pulmonary arteries with Doppler ultrasonography.

OBJECTIVE: The aim of the study was to determine the utility of ultrasonographically recorded blood flow waveforms of the pulmonary artery in the diagnosis of pulmonary hypoplasia. STUDY DESIGN: The normal values of the pulsatility index and peak systolic flow of pulmonary arterial blood velocity waveforms were determined in 300 uncomplicated single fetus pregnancies with well-established gestational ages between 24 and 40 weeks. We also measured the same parameters in 5 fetuses at high risk for development of severe pulmonary hypoplasia. We also determined the radial alveolar count and microvessel density, representing the extent of angiogenesis, in tissue specimens collected at autopsy from normal and hypoplastic lungs and stained both with hematoxylin and eosin and immunohistochemically for factor VIII. RESULTS: In healthy fetuses the pulsatility index values of both the right and left pulmonary arteries diminished significantly with advancing gestation, whereas the peak systolic velocity increased significantly with advancing gestation. In fetuses with pulmonary hypoplasia pulsatility index values were high and the peak systolic flow was significantly lower than in healthy fetuses. Histologic examination showed a lower radial alveolar count and poorer angiogenesis in fetuses with pulmonary hypoplasia than in healthy fetuses. CONCLUSION: Doppler ultrasonographic determination of pulmonary artery blood velocity waveforms is a useful tool for the diagnosis of pulmonary hypoplasia.

Blood Flow Velocity