PubMed HealthSearch

PubMed · 8468336

A method for measuring mechanical work and work efficiency during human activities.

Abstract

A major limitation in understanding human energy balance is the ability to accurately quantify the amount of physical activity or work performed by human subjects. We describe the development and validation of a force platform (2.5 x 2.5 m) system for measuring external mechanical work performed by human subjects. The force platform system was constructed inside a whole-room indirect calorimeter, thus, allowing simultaneous measurement of the energy expenditure associated with physical activity. We demonstrated the accuracy of the system for measuring work performed using a solenoid (32 kg) to deliver controlled amounts of energy to the platform. In tests with human subjects we demonstrated that the system can accurately and reproducibly measure work performed, energy expenditure associated with work performed, and work efficiency (work performed divided by energy expenditure). Overall, we obtained high correlations (an average of 0.932 for 33 subjects), between mechanical work performed and energy expenditure. We believe this mechanical work-energy expenditure system will be useful in determining the importance of individual differences in amount and cost of physical activity in the regulation of body weight and in development of obesity.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Sun, J O Hill. 1993. A method for measuring mechanical work and work efficiency during human activities.. https://doi.org/10.1016/0021-9290(93)90361-h

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Donor-donor energy migration for determining intramolecular distances in proteins: I. Application of a model to the latent plasminogen activator inhibitor-1 (PAI-1).

A new fluorescence spectroscopic method is presented for determining intramolecular and intermolecular distances in proteins and protein complexes, respectively. The method circumvents the general problem of achieving specific labeling with two different chromophoric molecules, as needed for the conventional donor-acceptor transfer experiments. For this, mutant forms of proteins that contain one or two unique cysteine residues can be constructed for specific labeling with one or two identical fluorescent probes, so-called donors (d). Fluorescence depolarization experiments on double-labeled Cys mutant monitor both reorientational motions of the d molecules, as well as the rate of intramolecular energy migration. In this report a model that accounts for these contributions to the fluorescence anisotropy is presented and experimentally tested. Mutants of a protease inhibitor, plasminogen activator inhibitor type-1 (PAI-1), containing one or two cysteine residues, were labeled with sulfhydryl specific derivatives of 4,4-difluoro-4-borata-3a-azonia-4a-aza-s-indacence (BODIPY). From the rate of energy migration, the intramolecular distance between the d groups was calculated by using the Forster mechanism and by accounting for the influence of local anisotropic orientation of the d molecules. The calculated intramolecular distances were compared with those obtained from the crystal structure of PAI-1 in its latent form. To test the stability of parameters extracted from experiments, synthetic data were generated and reanalyzed.

Biophysics

Localized dynamic light scattering: a new approach to dynamic measurements in optical microscopy.

We present a new approach to probing single-particle dynamics that uses dynamic light scattering from a localized region. By scattering a focused laser beam from a micron-size particle, we measure its spatial fluctuations via the temporal autocorrelation of the scattered intensity. We demonstrate the applicability of this approach by measuring the three-dimensional force constants of a single bead and a pair of beads trapped by laser tweezers. The scattering equations that relate the scattered intensity autocorrelation to the particle position correlation function are derived. This technique has potential applications for measurement of biomolecular force constants and probing viscoelastic properties of complex media.

Biophysics