A panning DLT procedure for three-dimensional videography.

Abstract

The direct linear transformation (DLT) method [Abdel-Aziz and Karara, APS Symposium on Photogrammetry. American Society of Photogrammetry, Falls Church, VA (1971)] is widely used in biomechanics to obtain three-dimensional space coordinates from film and video records. This method has some major shortcomings when used to analyze events which take place over large areas. To overcome these shortcomings, a three-dimensional data collection method based on the DLT method, and making use of panning cameras, was developed. Several small single control volumes were combined to construct a large total control volume. For each single control volume, a regression equation (calibration equation) is developed to express each of the 11 DLT parameters as a function of camera orientation, so that the DLT parameters can then be estimated from arbitrary camera orientations. Once the DLT parameters are known for at least two cameras, and the associated two-dimensional film or video coordinates of the event are obtained, the desired three-dimensional space coordinates can be computed. In a laboratory test, five single control volumes (in a total control volume of 24.40 x 2.44 x 2.44 m3) were used to test the effect of the position of the single control volume on the accuracy of the computed three dimensional space coordinates. Linear and quadratic calibration equations were used to test the effect of the order of the equation on the accuracy of the computed three dimensional space coordinates. For four of the five single control volumes tested, the mean resultant errors associated with the use of the linear calibration equation were significantly larger than those associated with the use of the quadratic calibration equation. The position of the single control volume had no significant effect on the mean resultant errors in computed three dimensional coordinates when the quadratic calibration equation was used. Under the same data collection conditions, the mean resultant errors in the computed three dimensional coordinates associated with the panning and stationary DLT methods were 17 and 22 mm, respectively. The major advantages of the panning DLT method lie in the large image sizes obtained and in the ease with which the data can be collected. The method also has potential for use in a wide variety of contexts. The major shortcoming of the method is the large amount of digitizing necessary to calibrate the total control volume. Adaptations of the method to reduce the amount of digitizing required are being explored.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

B Yu, T J Koh, J G Hay. 1993. A panning DLT procedure for three-dimensional videography.. https://doi.org/10.1016/0021-9290(93)90036-e

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

The effect of excessive tibial torsion on the capacity of muscles to extend the hip and knee during single-limb stance.

Excessive tibial torsion, a rotational deformity about the long axis of the tibia, is common in patients with cerebral palsy who walk with a crouch gait. Previous research suggests that this deformity may contribute to crouch gait by reducing the capacity of soleus to extend the knee; however, the effects of excess external torsion on the capacity of other muscles to extend the stance limb during walking are unknown. A computer model of the musculoskeletal system was developed to simulate a range of tibial torsion deformities. A dynamic analysis was then performed to determine the effect of these deformities on the capacity of lower limb muscles to extend the hip and knee at body positions corresponding to the single-limb stance phase of a normal gait cycle. Analysis of the model confirmed that excessive external torsion reduces the extension capacity of soleus. In addition, our analysis revealed that several important muscles crossing the hip and knee are also adversely affected by excessive tibial torsion. With a tibial torsion deformity of 30 degrees , the capacities of soleus, posterior gluteus medius, and gluteus maximus to extend both the hip and knee were all reduced by over 10%. Since a tibial torsion deformity reduces the capacity of muscles to extend the hip and knee, it may be a significant contributor to crouch gait, especially when greater than 30 degrees from normal, and thus should be considered by clinicians when making treatment decisions.

Biomechanical Phenomena↗

Predicting the subject-specific primary stability of cementless implants during pre-operative planning: preliminary validation of subject-specific finite-element models.

Pre-operative planning help the surgeon in taking the proper clinical decision. The ultimate goal of this work is to develop numerical models that allow the surgeon to estimate the primary stability during the pre-operative planning session. The present study was aimed to validate finite-element (FE) models accounting for patient and prosthetic size and position as planned by the surgeon. For this purpose, the FE model of a cadaveric femur was generated starting from the CT scan and the anatomical position of a cementless stem derived by a skilled surgeon using a pre-operative CT-based planning simulation software. In-vitro experimental measurements were used as benchmark problem to validate the bone-implant relative micromotions predicted by the patient-specific FE model. A maximum torque in internal rotation of 11.4 Nm was applied to the proximal part of the hip stem. The error on the maximum predicted micromotion was 12% of the peak micromotion measured experimentally. The average error over the entire range of applied torques was only 7% of peak measurement. Hence, the present study confirms that it is possible to accurately predict the level of primary stability achieved for cementless stems using numerical models that account for patient specificity and surgical variability.

Biomechanical Phenomena↗

Experimental validation of intact and implanted distal femur finite element models.

Four finite element (FE) models of intact and distal femur of knee replacements were validated relative to measured bone strains. FE models of linear tetrahedrons were used. Femoral replacements with cemented stemless, cemented and noncemented femoral stems of the PFC Sigma Modular Knee System were analyzed. Bone strains were recorded at ten locations on the cortex. The magnitude of the FE bone strains corresponded to the mean measured strains, with an overall agreement of 10%. Linear regression between the FE and mean experimental strains produced slopes between 0.94 and 1.06 and R(2) values between 0.92 and 0.99. RSME values were less than 12%. The FE models were able to adequately replicate the mechanical behavior of distal femur reconstructions.

Biomechanical Phenomena↗