Assessing enzyme substrate specificity using combinatorial libraries and electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry.

Abstract

A model experiment for the 'on-line' screening of substrate libraries by enzymes using combinatorial libraries in combination with electrospray ionization-Fourier transform ion cyclotron resonance (ESI-FTICR) mass spectrometry has been performed. The reaction between the electrophilic substrate 1-chloro-2,4-dinitrobenzene and component of a H-gamma-Glu-Cys-Xxx-OH library, catalyzed by glutathione-S-transferase, has been monitored. It shows the feasibility of 'two-dimensional' screening of substrate libraries by ESI-FTICR mass spectrometry.

Explore related subjects

Keep this discovery

Explore connections, maps & timelines

BibTeXRIS

M Wigger, J P Nawrocki, C H Watson, J R Eyler, S A Benner. 1997. Assessing enzyme substrate specificity using combinatorial libraries and electrospray ionization-Fourier transform ion cyclotron resonance mass spectrometry.. https://doi.org/10.1002/(sici)1097-0231(19971030)11%3A16%3C1749%3A%3Aaid-rcm91%3E3.0.co%3B2-g

Cite the original work for its findings. Save a collection to share your selection of sources.

KEEP EXPLORING

Related citations

Genotyping of simple and compound short tandem repeat loci using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry.

The utility of electrospray ionization Fourier transform ion cyclotron resonance (ESI-FIICR) mass spectrometry as a new approach for genotyping short tandem repeats (STRs) is demonstrated. STRs are currently valued as a powerful source of genetic information with repeats that range in structure from simple to hypervariable. Two tetranucleotide STR loci were chosen to evaluate ESI-FTICR mass spectrometry as a tool for genotyping: HUM-TH01, a simple STR with nonconsensus alleles, and vWA, a compound STR with nonconsensus alleles. For HUM-TH01, the genotype (i.e., repeat number of each allele) was determined for each of 30 individuals using mass measurements of double-stranded amplicons. Low-intensity peaks observed in the spectra of amplicons derived from heterozygous individuals were identified by mass as heteroduplexes that had formed between nonhomologous strands. Mass measurement of the double-stranded vWA amplicon was not sufficient for determining whether the individual was homozygous for allele subtype 18 or 18' since the amplicons differ by only 0.99 Da. Therefore, single-stranded amplicons were generated by incorporating a phosphorylated primer, prepared using T4 polynucleotide kinase, into the PCR phase and subsequently digesting the bottom strand using lambda-exonuclease. Accurate mass measurements were obtained for the single-stranded amplicons using internal calibration and the addition of a correction factor to adjust for the natural variation of isotopic abundances, confirming that the individual is homozygous for allele 18. Our results clearly demonstrate that ESI-FTICR mass spectrometry is a powerful approach to characterize both simple and compound STRs beyond the capabilities of electrophoretic technologies.

Cyclotrons↗

High-mass accuracy of product ions produced by SORI-CID using a dual electrospray ionization source coupled with FTICR mass spectrometry.

High-mass accuracy is demonstrated using internal calibration for product ions produced by sustained off-resonance irradiation collision-induced dissociation (SORI-CID) of a 15-mer oligonucleotide, 5'-(CTG)5-3'. Internal calibration for this tandem MS experiment was accomplished using a dual electrospray ionization (ESI) source coupled with Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) utilizing hexapole accumulation and gated trapping. The pulse sequence entails injection, trapping, and gas-phase isolation of the precursor ion of interest followed by the SORI-CID of this ion and, subsequently, injection and trapping of the internal mass calibrant (i.e., poly(ethylene glycol) with a 1000 Da average mass). The product ions and the poly(ethylene glycol) ions are then simultaneously excited by a broadband frequency chirp excitation waveform and detected. This technique corrects for space-charge effects on the measurement of an ion's cyclotron frequency experienced when externally calibrated data are used. While external calibration for FTICR-MS can result in mass errors of greater than 100 ppm, this internal standardization method demonstrated significantly more consistent accurate mass measurements with average mass errors ranging from -1.2 to -3.2 ppm for the 15-mer oligonucleotide used in this study. This method requires limited modifications to ESI-FTICR mass spectrometers and is applicable for both positive and negative modes of ionization as well as other sample types (e.g., pharmaceuticals, proteins, etc.).

Cyclotrons↗

Tandem mass spectrometric accurate mass performance of time-of-flight and Fourier transform ion cyclotron resonance mass spectrometry: a case study with pyridine derivatives.

The interpretation of mass spectra is a key process during compound identification, and the combination of tandem mass spectrometry (MS/MS) with high-accuracy mass measurements may deliver crucial information on the identity of a compound. Obtaining accurate mass data of fragment ions in MS/MS reveals the particular problem of mass calibration when a lockmass, which is frequently used to obtain accurate masses in MS, is absent. An alternative technique is to recalibrate the MS/MS spectrum using a reference MS/MS spectrum acquired under the same conditions. We have tested and validated this approach using a hybrid quadrupole/orthogonal acceleration reflectron-type time-of-flight (TOF) mass spectrometer. The results were compared with those obtained under similar conditions on a Fourier transform ion cyclotron resonance (FT-ICR) instrument. We found that the mass accuracy observed with such an "external" recalibration on the TOF instrument in MS/MS is identical to what can be obtained on a similar instrument operating in one-dimensional MS mode using the lockmass technique. However, mass accuracy in both cases is one order of magnitude inferior to that obtained using FTMS, and also inferior to that observed using sector field MS when operated at comparable resolution. Nevertheless, for small (<200 Da) molecules, this mass accuracy was still sufficient to have the "true" elemental composition identified as the first hit in about 70% of all cases. It was possible to elucidate the fragmentation mechanism of eight azaheterocycles containing a pyridine moiety, where the accurate mass data from the TOF instrument allowed distinction between two alternative fragmentation pathways.

Cyclotrons↗