PubMed Health⌕ Search

SEARCH · PubMed Health

Results for “Microfluidics”

Explore indexed PubMed citations for clinical trials, systematic reviews and public health research. Read source abstracts and follow each citation to its original PubMed record.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 541 records · Page 30Linked to original sources

Air-cooled cold trap channel integrated in a microfluidic device for monitoring airborne BTEX with an improved detection limit.

We integrated an air-cooled cold trap (CT) channel in a microfluidic device for monitoring airborne benzene, toluene, ethylbenzene, and xylene (BTEX) gases and demonstrated its effect on improving the detection limit of the microfluidic device. The device consists of concentration and detection cells formed of 3 x 1 cm Pyrex plates. We first introduced a sample gas into the concentration cell, and the gas was adsorbed onto an adsorbent in the channel. We then raised the temperature using a thin-film heater and introduced the desorbed gas into the detection cell. To prevent dilution of the gas before detection, we propose an improvement to the concentration cell structure that involves the integration of the CT channel. We examined the CT effect by comparing three types of concentration cell with different channel structures. We found that we could detect a gas concentration about 2 orders of magnitude lower than in our previous work by optimizing the channel structure and integrating a CT channel. As an example of BTEX detection,we obtained a 0.05 ppm detection limit for toluene gas with a sampling time of 30 min.

Adsorption↗

Analysis of lipoproteins by capillary zone electrophoresis in microfluidic devices: assay development and surface roughness measurements.

The development of a new assay for lipoproteins by capillary electrophoresis in fused-silica capillaries and in glass microdevices is described in this paper. The separation of low-density (LDL) and high-density (HDL) lipoproteins by capillary zone electrophoresis is demonstrated in fused-silica capillaries with both UV absorption and laser-induced fluorescence detection. This separation was accomplished using Tricine buffer (pH 9.0) with methylglucamine added as a dynamic coating. With UV detection, LDL eluted as a relatively sharp peak with a migration time of approximately 11 min and HDL eluted as a broad peak with a migration time of 12.5 min. Fluorescence detection of lipoproteins stained with NBD-ceramide was used with the same buffer system to give comparable results. Furthermore, fluorescence staining of human serum samples yielded results similar to the fluorescently stained LDL and HDL fractions, showing that this method can be used to quantify lipoproteins in serum samples. The method was also used to detect lipoproteins in glass micro-CE devices. Very similar results were obtained in microdevices although with much faster analysis times, LDL eluted as a sharp peak at approximately 25 s and HDL as a broad peak at slightly longer time. In addition, higher resolution was obtained on chips. To our knowledge, these results show the first separation and detection of lipoproteins in a microfluidic device using native serum samples. Atomic force microscopy was used to characterize the rms surface roughness (Rq) of microfluidic channels directly. Devices with different surface roughness values were fabricated using two different etchants for Pyrex wafers with a polysilicon masking layer. Using 49% HF, the measured roughness is Rq = 10.9 +/- 1.6 nm and with buffered HF (NH4F + HF) the roughness is Rq = 2.4 +/- 0.7 nm. At this level of surface roughness, there is no observable effect on the performance of the devices for this lipoprotein separation.

Chromatography, Gel↗

Microfluidic enzyme immunoassay using silicon microchip with immobilized antibodies and chemiluminescence detection.

Silicon microchips with immobilized antibodies were used to develop microfluidic enzyme immunoassays using chemiluminescence detection and horseradish peroxidase (HRP) as the enzyme label. Polyclonal anti-atrazine antibodies were coupled to the silicon microchip surface with an overall dimension of 13.1 x 3.2 mm, comprising 42 porous flow channels of 235-microm depth and 25-microm width. Different immobilization protocols based on covalent or noncovalent modification of the silica surface with 3-aminopropyltriethoxysilane (APTES) or 3-glycidoxypropyltrimethoxysilane (GOPS), linear polyethylenimine (LPEI, MW 750,000), or branched polyethylenimine (BPEI, MW 25,000), followed by adsorption or covalent attachment of the antibody, were evaluated to reach the best reusability, stability, and sensitivity of the microfluidic enzyme immunoassay (microFEIA). Adsorption of antibodies on a LPEI-modified silica surface and covalent attachment to physically adsorbed BPEI lead to unstable antibody coatings. Covalent coupling of antibodies via glutaraldehyde (GA) to three different functionalized silica surfaces (APTES-GA, LPEI-GA, and GOPS-BPEI-GA) resulted in antibody coatings that could be completely regenerated using 0.4 M glycine/HCl, pH 2.2. The buffer composition was shown to have a dramatic effect on the assay stability, where the commonly used phosphate buffer saline was proved to be the least suitable choice. The best long-term stability was obtained for the LPEI-GA surface with no loss of antibody activity during one month. The detection limits in the microFEIA for the three different immuno surfaces were 45, 3.8, and 0.80 ng/L (209, 17.7, and 3.7 pM) for APTES-GA, LPEI-GA, and GOPS-BPEI-GA, respectively.

Antibodies↗

Immobilization of DNA hydrogel plugs in microfluidic channels.

Acrylamide-modified DNA probes are immobilized in polycarbonate microfluidic channels via photopolymerization in a polyacrylamide matrix. The resulting polymeric, hydrogel plugs are porous under electrophoretic conditions and hybridize with fluorescently tagged complementary DNA. The double-stranded DNA can be chemically denatured, and the chip may be reused with a new analytical sample. Conditions for photopolymerization, hybridization, and denaturation are discussed. We also demonstrate the photopolymerization of plugs containing different DNA probe sequences in one microfluidic channel, thereby enabling the selective detection of multiple DNA targets in one electrophoretic pathway.

Biopolymers↗

Integrated microfluidic system enabling (bio)chemical reactions with on-line MALDI-TOF mass spectrometry.

A continuous flow micro total analysis system (micro-TAS) consisting of an on-chip microfluidic device connected to a matrix assisted laser desorption ionization [MALDI] time-of-flight [TOF] mass spectrometer (MS) as an analytical screening system is presented. Reaction microchannels and inlet/outlet reservoirs were fabricated by powderblasting on glass wafers that were then bonded to silicon substrates. The novel lab-on-a-chip was realized by integrating the microdevice with a MALDI-TOFMS standard sample plate used as carrier to get the microfluidic device in the MALDI instrument. A novel pressure-driven pumping mechanism using the vacuum of the instrument as a driving force induces flow in the reaction microchannel in a self-activating way. Organic syntheses as well as biochemical reactions are carried out entirely inside the MALDI-MS ionization vacuum chamber and analyzed on-line by MALDI-TOFMS in real time. The effectiveness of the micro-TAS system has been successfully demonstrated with several examples of (bio)chemical reactions.

Amino Acid Sequence↗

Multiple open-channel electroosmotic pumping system for microfluidic sample handling.

The development of a novel, fully integrated, miniaturized pumping system for generation of pressure-driven flow in microfluidic platforms is described. The micropump, based on electroosmotic pumping principles, has a multiple open-channel configuration consisting of hundreds of parallel, small-diameter microchannels. Specifically, pumps with microchannels of 1-6 microm in depth, 4-50 mm in length, and an overall area of a few square millimeters, were constructed. Flow rates of 10-400 nL/min were generated in electric-field-free regions in a stable, reproducible and controllable manner. In addition, eluent gradients were created by simultaneously using two pumps. Pressures up to 80 psi were produced with the present pump configurations. The pump can be easily interfaced with other operational elements of a micrototal analysis system (micro-TAS) device with multiplexing capabilities. A new microfluidic valving system was also briefly evaluated in conjunction with these pumps. The micropump was utilized to deliver peptide samples for electrospray ionization-mass spectrometric (ESI-MS) detection.

Electrochemistry↗

A two-channel microfluidic sensor that uses anodic electrogenerated chemiluminescence as a photonic reporter of cathodic redox reactions.

This paper describes a new approach for sensing electrochemically active substrates in microfluidic systems. This two-electrode sensor relies on electrochemical detection at one electrode and electrogenerated chemiluminescent (ECL) reporting at the other. Each microfabricated indium tin oxide electrode is located in a separate microfluidic channel, but the channels are connected downstream of the electrodes to maintain a complete electrical circuit. Because of laminar flow, there is no bulk mixing of the fluids in the detecting and reporting channels. This approach allows the ECL reaction to be physically and chemically decoupled from the sensing channel of the device, which greatly expands the number of analytes that can be detected. However, because the cathode and anode are connected, electron-transfer processes occurring at the sensing electrode are electrically coupled to the ECL reaction. Charge balance permits the ECL light output to be quantitatively correlated to electrochemical reductions at the cathode. The system is used to detect Fe(CN)6(3-), Ru(NH3)6(3+), and benzyl viologen and report their presence via Ru(bpy)3(2+) (bpy = bipyridine) luminescence. Each different redox target initiates ECL at a unique potential bias related to its standard redox potential. The influence of the concentrations of Ru(bpy)3(2+) and the target analytes is discussed.

Journal Article↗

Reactive polymer coatings: a first step toward surface engineering of microfluidic devices.

We report fabrication, characterization, and use of microfluidic analysis devices containing surface-immobilized cell-capturing molecules. Amino-terminated biotin ligands are immobilized onto the luminal surface of a microdevice and effectively support self-assembly of proteins, antibodies, and mammalian cells. For this purpose, chemical vapor deposition (CVD) polymerization is used to functionalize PDMS-made microfluidic devices with poly[para-xylylene carboxylic acid pentafluorophenolester-co-para-xylylene]. The resulting reactive coating shows excellent adhesion when deposited in thin films (approximately 100 nm, and the distribution of the pentafluorophenol ester groups is reasonably uniform within the microchannel inner surface, as examined by fluorescence microscopy. The utility of these devices for cell-based bioassays is demonstrated by monitoring the concentration-dependent effect of the disintegrin echistatin on cell adhesion. The described assay format could be relevant to clinical research in various fields, including angiogenesis research.

Animals↗

Nanocapillary array interconnects for gated analyte injections and electrophoretic separations in multilayer microfluidic architectures.

An electrokinetic injection technique is described which uses a nuclear track-etched nanocapillary array to inject sample plugs from one layer of a microfluidic device into another vertically separated layer for electrophoretic separations. Gated injection protocols for analyte separations, reported here, establish nanocapillary array interconnects as a route to multilevel microfluidic analytical designs. The hybrid nanofluidic/microfluidic gated injection protocol allows sample preparation and separation to be implemented in separate horizontal planes, thereby achieving multilayer integration. Repeated injections and separations of FITC-labeled arginine and tryptophan, using 200-nm pore-diameter capillary array injectors in place of traditional cross injectors are used to demonstrate gated injection with a bias configuration that uses relay switching of a single high-voltage source. Injection times as rapid as 0.3 s along with separation reproducibilities as low as 1% for FITC-labeled arginine exemplify the capability for fast, serial separations and analyses. Impedance analysis of the micro-/nanofluidic network is used to gain further insight into the mechanism by which this actively controlled nanofluidic-interconnect injection method works. Gated sample introduction via a nanocapillary array interconnect allows the injection and separation protocols to be optimized independently, thus realizing the versatility needed for real-world implementation of rapid, serial microchip analyses.

Arginine↗

Spatial two-photon fluorescence cross-correlation spectroscopy for controlling molecular transport in microfluidic structures.

The increasing availability of microfluidic systems of various geometries and materials for the downscaling of chemical or biochemical processes raises a strong demand for adequate techniques to precisely determine flow parameters and to control fluid and particle manipulation. Of all readout parameters, fluorescence analysis of the fluid or suspended particles is particularly attractive, as it can be employed without mechanical interference and with a sensitivity high enough to detect single molecules in aqueous environments. In this study, we present the determination of flow parameters, such as velocity and direction, in microstructured channels by fluorescence correlation spectroscopy (FCS), a method based on single molecule spectroscopy carried out in confocal optical setups. Different modes of FCS, such as auto- and dual-beam cross-correlation techniques by one- and two-photon excitation, are discussed. Known advantages of two-photon excitation, such as highly restricted detection volumes and low scattering background, are shown to be particularly valuable for measurements in tiny channel systems. Although conventional autocorrelation is sufficient for describing the velocity of single molecules, dual-beam cross-correlation allows the separation of isotropic and anisotropic dynamics, for example, to monitor flow directions or to discriminate against photophysical effects that could be mistaken for mobility parameters. It can be shown that time-gated two-photon excitation in the dual-beam mode significantly lowers the undesired cross-talk between the two measurement volumes. Finally, some applications, such as the calibration of microfluidic sorting units and flow profiling, are demonstrated.

Cell Separation↗

Surface modification of poly(dimethylsiloxane) microfluidic devices by ultraviolet polymer grafting.

Poly(dimethylsiloxane) (PDMS)-based microfluidic devices are increasing in popularity due to their ease of fabrication and low costs. Despite this, there is a tremendous need for strategies to rapidly and easily tailor the surface properties of these devices. We demonstrate a one-step procedure to covalently link polymers to the surface of PDMS microchannels by ultraviolet graft polymerization. Acrylic acid, acrylamide, dimethylacrylamide, 2-hydroxylethyl acrylate, and poly(ethylene glycol)monomethoxyl acrylate were grafted onto PDMS to yield hydrophilic surfaces. Water droplets possessed contact angles as low as 45 degrees on the grafted surfaces. Microchannels constructed from the grafted PDMS were readily filled with aqueous solutions in contrast to devices composed of native PDMS. The grafted surfaces also displayed a substantially reduced adsorption of two test peptides compared to that of oxidized PDMS. Microchannels with grafted surfaces exhibited electroosmotic mobilities intermediate to those displayed by native and oxidized PDMS. Unlike the electroosmotic mobility of oxidized PDMS, the electroosmotic mobility of the grafted surfaces remained stable upon exposure to air. The electrophoretic resolution of two test peptides in the grafted microchannels was considerably improved compared to that in microchannels composed of oxidized PDMS. By using the appropriate monomer, it should be possible to use UV grafting to impart a variety of surface properties to PDMS microfluidics devices.

Dimethylpolysiloxanes↗

Selective ion extraction: a separation method for microfluidic devices.

A separation concept, selective ion extraction (SIE), is proposed on the basis of the combination of hydrodynamic and electrokinetic flow controls in microfluidic devices. Using a control system with multiple pressure and voltage sources, the hydrodynamic flow and electric field in any section of the microfluidic network can be set to desired values. Mixtures of compounds sent into a T-junction on a chip can be completely separated into different channels on the basis of their electrophoretic mobilities. A simple velocity balance model proved useful for predicting the voltage and pressure settings needed for separation. SIE provides a highly efficient separation with minimal additional dispersion. It is an ideal technique for high-throughput screening systems and demonstrates the power of lab-on-a-chip systems.

Journal Article↗

Electrokinetic injection techniques in microfluidic chips.

The separation efficiency of a microfluidic chip is influenced to a significant degree by the flow field conditions within the injection microchannel. Therefore, an understanding of the physics of the flow within this channel is beneficial in the design and operation of such a system. The configuration of an injection system is determined by the volume of the sample plug that is to be delivered to the separation process. Accordingly, this paper addresses the design and testing of injection systems with a variety of configurations, including a simple cross, a double-T, and a triple-T configuration. This paper also presents the design of a unique multi-T injection configuration. Each injection system cycles through a predetermined series of steps, in which the electric field magnitude and distribution within the various channels is strictly manipulated, to effectuate a virtual valve. The uniquemulti-T configuration injection system presented within this paper has the ability to simulate the functions of the cross, double-T, and triple-T systems through appropriate manipulations of the electric field within its various channels. In other words, the proposed design successfully combines several conventional injection systems within a single microfluidic chip.

Journal Article↗

Gateable nanofluidic interconnects for multilayered microfluidic separation systems.

The extension of microfluidic devices to include three-dimensional fluidic networks allows complex fluidic and chemical manipulations but requires innovative methods to interface fluidic layers. Externally controllable interconnects, employing nuclear track-etched polycarbonate membranes containing nanometer-diameter capillaries, are described that produce hybrid three-dimensional fluidic architectures. Controllable nanofluidic transfer is achieved by controlling applied bias, polarity, and density of the immobile nanopore surface charge and the impedance of the nanocapillary array relative to the microfluidic channels. Analyte transport between vertically separated microchannels has three stable transfer levels, corresponding to zero, reverse, and forward bias. The transfer can even depend on the properties of the analyte being transferred such as the molecular size, illustrating the flexible character of the analyte transfer. In a specific analysis implementation, nanochannel array gating is applied to capillary electrophoresis separations, allowing selected separated components to be isolated for further manipulation, thereby opening the way for preparative separations at attomole analyte mass levels.

Electrophoresis, Capillary↗

Microfluidic actuation using electrochemically generated bubbles.

Bubble-based actuation in microfluidic applications is attractive owing to elementary microfabrication requirements. In the present study, the mechanical and chemical characteristics of electrochemically generated bubble valves were studied. By generating electrochemical bubbles as valves directly inside the channel, valves could be closed and opened in milliseconds. Whereas bubble inflation (or valve closing) rate increases with applied voltage, small microfluidic dimensions accelerate bubble deflation rates. It is found that bubbles need not collapse fully to restore full flow, and the channel opens when its hydraulic resistance equals that between the bubble and the wall--a process requiring only milliseconds. Since only picomoles of salt are needed to generate bubbles, pH gradients that are invariably associated with electrochemical reactions were readily suppressed by using a small amount of buffer, as visualized by a pH-sensitive fluorescent dye. A range of common laboratory reagents and electrolytes in varying concentrations, including weak to strong acids and bases, as well as nonaqueous/aqueous mixtures were successfully tested. Using such bubble valves, an eight-way multiplexer was fabricated and tested.

Buffers↗

Autonomous microfluidic capillary system.

The transport of minute amounts of liquids using microfluidic systems has opened avenues for higher throughput and parallelization of miniaturized bio/chemical processes combined with a great economy of reagents. In this report, we present a microfluidic capillary system (CS) that autonomously transports aliquots of different liquids in sequence: liquids pipetted into the service port of the CS flow unidirectionally through the various sections of the CS, which comprises a 15-pL reaction chamber, into the capillary pump. A CS can thus be operated by simply delivering the different samples to its service port. The liquid transport concept presented here is advantageous because the pumping and valving functions are integrated into the device by means of capillary phenomena, and it therefore does not require any external power supply or control device. Thus, arrays of CSs can easily be formed by cloning a functional CS. Alternatively, the flow of liquids in CSs can also be interactively tuned if desired by (i) forcing the evaporating of liquid out of the capillary pumps and (ii) by contacting a secondary, removable capillary pump to the embedded ones. We illustrate the possibilities of CSs by conducting a surface immunoassay for a cardiac marker, within 25 min, on an area of 100 x 100 microm2, using 16 sequential filling steps.

Journal Article↗

A multichannel microfluidic sensor that detects anodic redox reactions indirectly using anodic electrogenerated chemiluminescence.

Here, we describe a new approach for detecting redoxactive targets by electrochemical oxidation and reporting their presence by electrogenerated chemiluminescence (ECL) based on electrochemical oxidation of Ru(bpy)3(2+) (bpy = 2,2'-bipyridine) and tripropylamine (TPA). This new strategy, which complements our previous reports of using ECL to signal the presence of targets undergoing electrochemical reduction, takes advantage of many of the attractive attributes of microfluidic-based electrochemical cells. These attributes include close proximity of multiple flow channels and electrodes, ability to move reagents through channels under laminar flow conditions, and the capacity to precisely place device components relative to one another using photolithography. Specifically, the microfluidic electrochemical sensor described here consists of three channels. The analyte and ECL reporting cocktail flow through separate channels, but they share a common anode. The cathode resides in a channel containing a sacrificial reductant. In this configuration, the target analyte competes with Ru(bpy)3(2+) and TPA to provide electrons for the reductant. Accordingly, in this competitive assay approach, the presence of the analyte is signaled as a lowering of the ECL intensity. In this report, the device performance characteristics are reported, and the detection of both ferrocyanide and dopamine is demonstrated at micromolar concentrations.

Journal Article↗

Microfluidic device for single-cell analysis.

We have developed a novel microfluidic device constructed from poly(dimethylsiloxane) using multilayer soft lithography technology for the analysis of single cells. The microfluidic network enables the passive and gentle separation of a single cell from the bulk cell suspension, and integrated valves and pumps enable the precise delivery of nanoliter volumes of reagents to that cell. Various applications are demonstrated, including cell viability assays, ionophore-mediated intracellular Ca2+ flux measurements, and multistep receptor-mediated Ca2+ measurements. These assays, and others, are achieved with significant improvements in reagent consumption, analysis time, and temporal resolution over macroscale alternatives.

Calcium↗